Shipping included*
Exclusions
Additional shipping fees may apply in rare circumstances for deliveries outside standard service areas. In most cases, this only potentially affects shipments to the Northwest Territories and Yukon, as well as certain heavy or oversized items.
Tripp Lite by Eaton SU10KRT3U Tripp Lite SmartOnline UPS - 10kVA/9000W Double-Conversion Rack/Tower - 4. 3 Min Full Load Runtime
Business volume discounts
Technical guidance
Preparation & staging
QC · ON · AB · BC
Product Features
Technical Overview
This SmartOnline UPS employs double-conversion technology that continuously converts incoming AC power to DC and back to clean AC, isolating connected equipment from power anomalies. The 0.9 power factor ensures efficient power utilization, while the 0 ns transfer time guarantees no interruption during utility power failures.
The system includes comprehensive monitoring through a 6-LED display showing line power, bypass, inverter, charger, output AC, and battery status. A selectable LCD provides detailed readouts of input/output voltage, frequency, battery voltage, charge level, and system warnings.
This section brings together practical product details such as Plug/Connector Type, Transfer Time, Load Capacity (VA), Load Capacity (Watt), so buyers can judge configuration, deployment fit, and day-to-day suitability with less guesswork.
A strong technical summary explains how the product's interfaces, hardware profile, and operating characteristics work together in real deployment. Buyers often need this context to confirm compatibility with existing devices, expected performance in daily use, and whether installation will be straightforward for IT staff or end users.
Key Product Advantages
The SU10KRT3U delivers enterprise-grade power protection with features specifically designed for high-availability environments. Hot-swappable modules allow for battery replacement and maintenance without shutting down connected equipment, while the 9U form factor provides installation flexibility in both rack and tower configurations.
Advanced Monitoring & Management
SNMP management capabilities enable remote monitoring and control through network interfaces. The system includes USB, RS232, and EPO ports, with support for optional SNMP/WEB and contact-closure cards for integration into existing management infrastructure.
- SNMP Manageable
- USB & RS232 Ports
- EPO Support
- Optional Management Cards
Comprehensive Alarm System
Multiple alarm conditions provide immediate notification of system status, including on battery, low battery, overload, UPS fault, and remote shutdown events. This ensures prompt response to any power-related issues.
- On Battery Alert
- Low Battery Warning
- Overload Detection
- Fault Notification
Deployment / Use Cases
The Tripp Lite SmartOnline SU10KRT3U is ideal for protecting critical infrastructure in data centers, server rooms, and network closets. Its 10kVA capacity supports multiple servers, storage arrays, and networking equipment simultaneously, making it suitable for small to medium business server environments and edge computing deployments.
The rack/tower dual compatibility allows installation in standard 19-inch rack enclosures or as a standalone tower unit. This flexibility makes the UPS adaptable to various IT environments, from dedicated data centers to office server rooms with limited rack space.
Data Center Protection
Provides clean, continuous power to server racks, storage systems, and network switches during utility outages or power disturbances. The 4.3-minute full-load runtime allows for orderly shutdown or generator transfer.
High-Availability Applications
Supports critical systems that require zero-interruption power, including VoIP systems, security infrastructure, and medical equipment. The double-conversion technology ensures power quality regardless of input conditions.
Physical Profile
The SU10KRT3U occupies 9U of rack space with dimensions of 40" height, 25.50" width, and 41" depth (1016 x 647.7 x 1041.4 mm). The unit weighs approximately 469 lb (212.7 kg) and includes mounting hardware for both 4-post rackmount enclosures and tower stands. The substantial construction reflects the robust internal components designed for continuous operation in demanding environments.
- Width
- 25.50" (647.70 mm)
- Depth
- 41" (1041.40 mm)
- Height
- 40" (1016 mm)
- Weight
- 469 lb (212734.82 g)
What's in the Box
The package includes the complete SU10KRT3U UPS system with all necessary components for immediate deployment.
Highlights
- 10kVA/9000W double-conversion online UPS with 0.9 power factor
- 4.3-minute full-load runtime and 12.5-minute half-load runtime
- Pure sine wave output with 0 ns transfer time
- 208/240V input with 200-240V output voltage range
- 9U rack/tower compatible form factor
- Hot-swappable power and battery modules
- SNMP management with USB, RS232, and EPO ports
- 6-LED display with selectable LCD for detailed monitoring
- 6-year battery life with 4-hour typical recharge time
- Includes PowerAlert software and mounting hardware
Specifications
| Specifications | |
|---|---|
| Manufacturer | Eaton Corporation |
| Manufacturer Part Number | SU10KRT3U |
| Brand Name | Tripp Lite series |
| Product Line | SmartOnline |
| Product Name | SmartOnline SU10KRT3U UPS |
| Product Type | Double Conversion Online UPS |
| Technical Information | |
| Plug/Connector Type | Hardwired |
| Transfer Time | 0 ns |
| Power Description | |
| Load Capacity (VA) | 10 kVA |
| Load Capacity (Watt) | 9 kW |
| Input Voltage | 208 V AC,240 V AC |
| Output Voltage | 240 V AC,200 V AC,208 V AC,220 V AC,230 V AC |
| Waveform Type | Sine Wave |
| Management | |
| Network Management | SNMP Manageable |
| Alarm | On Battery,Low Battery,Overload,UPS Fault,Remote Shutdown |
| Controls/Indicators | |
| Status Indicators | 6 LED DISPLAY: line power, bypass, inverter, charger, output AC and battery operation SELECTABLE LCD DISPLAY: input/output voltage, Hz, battery voltage and charge level and detailed warnings regarding all major UPS functions |
| Battery Information | |
| Battery Chemistry | Lead Acid |
| Backup/Run Time (Full Load) | 4.30 Minute |
| Backup/Run Time (Half Load) | 12.50 Minute |
| Battery Life | 6 Year |
| Hot Swappable | Yes |
| Typical Battery Recharge Time | 4 Hour |
| Environmental Conditions | |
| Maximum Operating Temperature | 104°F (40°C) |
| Physical Characteristics | |
| Height | 40" (1016 mm) |
| Width | 25.50" (647.70 mm) |
| Depth | 41" (1041.40 mm) |
| Weight (Approximate) | 469 lb (212734.82 g) |
| Miscellaneous | |
| Package Contents | SmartOnline SU10KRT3U UPS SU10KRT3U UPS System (power module, hardwire PDU, step-down transformer module and battery pack) PowerAlert Software and cabling Mounting hardware for 4 post rackmount enclosures/tower stands Instruction manual with warranty information |
| Country of Origin | China |
| Warranty | |
| Limited Warranty | 2 Year |
User Manual
FAQ
What is the power capacity of the Tripp Lite SU10KRT3U UPS?
The SU10KRT3U provides 10 kVA (10,000 VA) and 9 kW (9,000 watts) of power capacity with a 0.9 power factor. This double-conversion online UPS can support multiple servers, storage systems, and networking equipment simultaneously in small to medium business environments.
How long does this UPS provide backup power at full load?
At full load, the SU10KRT3U delivers 4.3 minutes of backup runtime. At half load, runtime extends to 12.5 minutes. These runtimes provide sufficient time for orderly system shutdown or transfer to generator power during utility outages.
Can this UPS be installed in both rack and tower configurations?
Yes, the SU10KRT3U is designed for dual deployment as either a 9U rackmount unit or standalone tower. The package includes mounting hardware for 4-post rackmount enclosures and tower stands, providing installation flexibility for different IT environments.
What management interfaces does this UPS support?
The UPS includes USB and RS232 ports for local management, plus support for SNMP network management. Optional SNMP/WEB and contact-closure cards are available for expanded monitoring capabilities. The system also features an EPO (Emergency Power Off) port for safety integration.
Are the battery modules hot-swappable in this UPS?
Yes, both the power and battery modules are hot-swappable, allowing for maintenance and replacement without shutting down connected equipment. This feature minimizes downtime and supports high-availability requirements in critical infrastructure deployments.
What input and output voltages does this UPS support?
The SU10KRT3U accepts 208V or 240V AC input and provides output voltages of 200V, 208V, 220V, 230V, or 240V AC. This wide voltage range accommodates various power configurations and includes economy mode options for improved efficiency during normal operation.
What power capacity is listed for this UPS?
The listed power specification is 10 kVA, which helps position the unit for the right load level and installation role.
What voltage details are listed?
The listed power specification is 208 V AC,240 V AC, which helps position the unit for the right load level and installation role.