Sidebar Sidebar Sidebar

Shipping included*

Tripp Lite by Eaton SU10KRT3UHV Tripp Lite SmartOnline Double Conversion Online UPS - 10kVA/9000W - 6U Rack/Tower - Hot-Swappable Battery

SKU: SU10KRT3UHV
UPC: 037332115935
(No reviews) Write a Review
MSRP: $12,452.47
$12,452.47
$7,087.99
Save: $5,364.48 (43.08%)
Warranty Information: 2 Year
Condition: New
Width: 66.04 (cm)
Height: 78.74 (cm)
Depth: 104.14 (cm)

Ask for ETA! 🗨️

Logo cards
B2B Pricing

Business volume discounts

IT Experts

Technical guidance

IT Configuration

Preparation & staging

Canada Stock

QC · ON · AB · BC

Product Features

Description

Product Overview

The Tripp Lite SmartOnline SU10KRT3UHV is a double conversion online UPS engineered for high-availability environments requiring zero-transfer-time power protection. This 10kVA/9000W unit delivers pure sine wave output across multiple voltage configurations, ensuring compatibility with sensitive server, networking, and storage equipment.

Built for both rack and tower deployment, the 6U form factor includes hot-swappable battery modules for maintenance-free operation. The system features comprehensive status indicators, SNMP management capabilities, and PowerAlert software integration for centralized monitoring and control across distributed IT infrastructure.

This section brings together practical product details such as Transfer Time, Load Capacity (VA), Load Capacity (Watt), Output Voltage, so buyers can judge configuration, deployment fit, and day-to-day suitability with less guesswork.

In practical terms, this overview should help a buyer understand what the product is, the type of environment it suits, and the core reasons it may be chosen over a more generic alternative. That context is especially useful for business purchasing, where fit, consistency, and ease of use usually matter as much as individual specifications.

Power
10 kVA
Power Capacity
240 V AC,220 V AC,230 V AC6U
Power Capacity
Load Capacity (VA)10 kVA
Load Capacity (Watt)9 kW
Output Voltage240 V AC,220 V AC,230 V AC
Battery & Runtime
Backup Time (Full Load)4.30 Minute
Backup Time (Half Load)12.50 Minute
Battery Life6 Year
Physical & Installation
Rack Height6U
Hot SwappableYes
Weight327.56 lb (148578.72 g)

Technical Overview

This SmartOnline UPS employs true double-conversion technology with 0 ns transfer time, eliminating any power interruption during grid failures. The 10 kVA/9000W capacity supports substantial server loads, while the selectable output voltages of 220V, 230V, and 240V AC provide installation flexibility across different power standards.

The lead-acid battery system delivers 4.3 minutes of runtime at full load and extends to 12.5 minutes at half load, with a typical 4-hour recharge cycle. Battery modules are hot-swappable, allowing replacement without system downtime, and carry a 6-year design life for reduced maintenance costs.

This section brings together practical product details such as Transfer Time, Load Capacity (VA), Load Capacity (Watt), Output Voltage, so buyers can judge configuration, deployment fit, and day-to-day suitability with less guesswork.

A strong technical summary explains how the product's interfaces, hardware profile, and operating characteristics work together in real deployment. Buyers often need this context to confirm compatibility with existing devices, expected performance in daily use, and whether installation will be straightforward for IT staff or end users.

Transfer Time0 ns
Maximum Operating Temperature104°F (40°C)
Typical Recharge Time4 Hour
Double ConversionPure Sine WaveSNMP Manageable

Key Product Advantages

The SU10KRT3UHV combines enterprise-grade power protection with flexible deployment options, making it ideal for data centers, server rooms, and critical network closets.

Zero Transfer Time Protection

Double conversion technology ensures continuous clean power with no switching delay during utility failures, protecting sensitive equipment from data loss and hardware damage.

  • 0 ns transfer time
  • Pure sine wave output
  • Isolates load from grid anomalies

Flexible Installation Options

The 6U chassis supports both rack-mount and tower configurations, with included hardware for 4-post rack enclosures and tower stands.

  • 6U rack height
  • Rack/tower compatible
  • 327.56 lb weight capacity

Maintenance-Friendly Design

Hot-swappable battery modules allow replacement without powering down connected equipment, while comprehensive monitoring provides early warning of system issues.

  • Hot-swappable batteries
  • 6-year battery life
  • LED and LCD status displays

Deployment / Use Cases

This UPS is designed for environments where power continuity is non-negotiable. The 10kVA capacity and rack/tower flexibility make it suitable for mixed infrastructure deployments.

Typical applications include protecting server racks in data centers, supporting networking equipment in telecom closets, and providing backup power for industrial control systems. The hardwire distribution module enables direct connection to critical loads, while the management interfaces support integration with existing monitoring systems.

This section brings together practical product details such as Transfer Time, Load Capacity (VA), Load Capacity (Watt), Output Voltage, so buyers can judge configuration, deployment fit, and day-to-day suitability with less guesswork.

Data Center Server Protection

Protect rack-mounted servers, storage arrays, and networking gear with zero-interruption power during utility fluctuations or outages.

Network Infrastructure Support

Ensure continuous operation of switches, routers, and security appliances in network closets and edge computing locations.

Physical Profile

The SU10KRT3UHV measures 31" high, 26" wide, and 41" deep, occupying 6U of rack space. The 327.56 lb unit includes mounting hardware for both 4-post rack enclosures and tower stands, providing installation flexibility. The chassis is engineered for data center environments with a maximum operating temperature of 104°F (40°C).

The physical profile is practical for deployment planning because the dimensions and weight are clearly defined: 31" (787.40 mm), 26" (660.40 mm), 41" (1041.40 mm), 327.56 lb (148578.72 g). This helps confirm rack, shelf, desk, or cabinet fit before installation.

Dimensions
Width
26" (660.40 mm)
Depth
41" (1041.40 mm)
Height
31" (787.40 mm)
Weight
327.56 lb (148578.72 g)

What's in the Box

The package includes everything needed for installation and operation.

SmartOnline SU10KRT3UHV UPS
[custom-highlights]

Highlights

  • 10kVA/9000W double conversion online UPS with 0 ns transfer time
  • Pure sine wave output at 220V/230V/240V AC for sensitive equipment
  • 6U rack/tower compatible chassis with flexible mounting options
  • Hot-swappable battery modules for maintenance without downtime
  • 4.3 minutes runtime at full load, 12.5 minutes at half load
  • SNMP manageable with USB, RS232, and EPO ports
  • Comprehensive status indicators with LED and LCD displays
  • Includes PowerAlert software for centralized monitoring
  • 6-year battery design life for reduced maintenance costs
  • 2-year limited warranty with full manufacturer support
[/custom-highlights][custom-specifications]

Specifications

Specifications
ManufacturerEaton Corporation
Manufacturer Part NumberSU10KRT3UHV
Brand NameTripp Lite series
Product LineSmartOnline
Product NameSmartOnline SU10KRT3UHV UPS
Product TypeDouble Conversion Online UPS
Technical Information
Transfer Time0 ns
Power Description
Load Capacity (VA)10 kVA
Load Capacity (Watt)9 kW
Output Voltage240 V AC,220 V AC,230 V AC
Waveform TypeSine Wave
Management
Network ManagementSNMP Manageable
AlarmOn Battery,Low Battery,Overload,UPS Fault,Remote Shutdown
Controls/Indicators
Status Indicators6 LED DISPLAY: line power, bypass, inverter, charger, output AC and battery operation. SELECTABLE LCD DISPLAY: input/output voltage, Hz, battery voltage and charge level and detailed warnings regarding all major UPS functions
Battery Information
Battery ChemistryLead Acid
Backup/Run Time (Full Load)4.30 Minute
Backup/Run Time (Half Load)12.50 Minute
Battery Life6 Year
Hot SwappableYes
Typical Battery Recharge Time4 Hour
Environmental Conditions
Maximum Operating Temperature104°F (40°C)
Physical Characteristics
Height31" (787.40 mm)
Width26" (660.40 mm)
Depth41" (1041.40 mm)
Rack Height6U
Weight (Approximate)327.56 lb (148578.72 g)
Miscellaneous
Package ContentsSmartOnline SU10KRT3UHV UPS SU10KRT3UHV Rack-Tower UPS System with hardwire distribution module and 1 BP240V10RT3U battery pack PowerAlert Software and cabling Mounting hardware for 4 post rack enclosures/tower stands Instruction manual with warranty information
Country of OriginChina
Warranty
Limited Warranty2 Year
[/custom-specifications][custom-user-manual]

User Manual

This section contains official documentation provided by the manufacturer, including product manuals, brochures, and supplementary materials.
[/custom-user-manual][custom-faq]

FAQ

What is the power capacity of this UPS?

The Tripp Lite SU10KRT3UHV provides 10 kVA (10,000 VA) and 9,000 watts of power capacity. This supports substantial server, storage, and networking equipment loads in data center and server room environments.

How long does the battery last during a power outage?

At full load, the UPS provides 4.3 minutes of runtime. At half load, runtime extends to 12.5 minutes. The actual runtime depends on the connected equipment's power draw, with lighter loads achieving longer backup periods.

Is this UPS rack-mountable or tower-style?

This unit is both rack and tower compatible. It occupies 6U of rack space and includes mounting hardware for 4-post rack enclosures as well as tower stands, providing installation flexibility for different environments.

Are the batteries hot-swappable?

Yes, the battery modules are hot-swappable. This allows replacement without powering down connected equipment, ensuring continuous operation during maintenance and reducing system downtime.

What management options are available?

The UPS supports SNMP management for network monitoring, along with USB and RS232 local connections. It includes PowerAlert software and supports contact-closure card options for integration with building management systems.

What output voltage does this UPS provide?

The unit delivers pure sine wave output at selectable voltages of 220V, 230V, and 240V AC. This flexibility accommodates different power standards and equipment requirements across various geographical regions.

What power capacity is listed for this UPS?

The listed power specification is 10 kVA, which helps position the unit for the right load level and installation role.

What voltage details are listed?

The listed power specification is 240 V AC,220 V AC,230 V AC, which helps position the unit for the right load level and installation role.

[/custom-faq]
Volume Discounts
Qty Price Available
Match Price Request

Found a lower price? Send us the link and we will do our best to match or beat it.

Request received. We will reply within 24 hours.
Fleet Network
Wholesale & B2B
Partner with Us

Looking to buy in bulk? We offer competitive pricing, dedicated support, and custom solutions for businesses of all sizes.

Volume Discounts

Tiered pricing structure designed to maximize your margins as you grow.

Dedicated Account Manager

Direct access to a specialist who understands your business needs.

Fast & Reliable Shipping

Priority processing and discounted shipping rates for bulk orders.

Request a Quote
Thank you!
Your request has been sent successfully.
Tripp Lite by Eaton SU10KRT3UHV Tripp Lite SmartOnline Double Conversion Online UPS - 10kVA/9000W - 6U Rack/Tower - Hot-Swappable Battery
MSRP: $12,452.47
$12,452.47
$7,087.99
Save: $5,364.48 (43.08%)
Out of stock