Shipping included*
Exclusions
Additional shipping fees may apply in rare circumstances for deliveries outside standard service areas. In most cases, this only potentially affects shipments to the Northwest Territories and Yukon, as well as certain heavy or oversized items.
Tripp Lite by Eaton SU10KRT3UHV Tripp Lite SmartOnline Double Conversion Online UPS - 10kVA/9000W - 6U Rack/Tower - Hot-Swappable Battery
Business volume discounts
Technical guidance
Preparation & staging
QC · ON · AB · BC
Product Features
Technical Overview
This SmartOnline UPS employs true double-conversion technology with 0 ns transfer time, eliminating any power interruption during grid failures. The 10 kVA/9000W capacity supports substantial server loads, while the selectable output voltages of 220V, 230V, and 240V AC provide installation flexibility across different power standards.
The lead-acid battery system delivers 4.3 minutes of runtime at full load and extends to 12.5 minutes at half load, with a typical 4-hour recharge cycle. Battery modules are hot-swappable, allowing replacement without system downtime, and carry a 6-year design life for reduced maintenance costs.
This section brings together practical product details such as Transfer Time, Load Capacity (VA), Load Capacity (Watt), Output Voltage, so buyers can judge configuration, deployment fit, and day-to-day suitability with less guesswork.
A strong technical summary explains how the product's interfaces, hardware profile, and operating characteristics work together in real deployment. Buyers often need this context to confirm compatibility with existing devices, expected performance in daily use, and whether installation will be straightforward for IT staff or end users.
Key Product Advantages
The SU10KRT3UHV combines enterprise-grade power protection with flexible deployment options, making it ideal for data centers, server rooms, and critical network closets.
Zero Transfer Time Protection
Double conversion technology ensures continuous clean power with no switching delay during utility failures, protecting sensitive equipment from data loss and hardware damage.
- 0 ns transfer time
- Pure sine wave output
- Isolates load from grid anomalies
Flexible Installation Options
The 6U chassis supports both rack-mount and tower configurations, with included hardware for 4-post rack enclosures and tower stands.
- 6U rack height
- Rack/tower compatible
- 327.56 lb weight capacity
Maintenance-Friendly Design
Hot-swappable battery modules allow replacement without powering down connected equipment, while comprehensive monitoring provides early warning of system issues.
- Hot-swappable batteries
- 6-year battery life
- LED and LCD status displays
Deployment / Use Cases
This UPS is designed for environments where power continuity is non-negotiable. The 10kVA capacity and rack/tower flexibility make it suitable for mixed infrastructure deployments.
Typical applications include protecting server racks in data centers, supporting networking equipment in telecom closets, and providing backup power for industrial control systems. The hardwire distribution module enables direct connection to critical loads, while the management interfaces support integration with existing monitoring systems.
This section brings together practical product details such as Transfer Time, Load Capacity (VA), Load Capacity (Watt), Output Voltage, so buyers can judge configuration, deployment fit, and day-to-day suitability with less guesswork.
Data Center Server Protection
Protect rack-mounted servers, storage arrays, and networking gear with zero-interruption power during utility fluctuations or outages.
Network Infrastructure Support
Ensure continuous operation of switches, routers, and security appliances in network closets and edge computing locations.
Physical Profile
The SU10KRT3UHV measures 31" high, 26" wide, and 41" deep, occupying 6U of rack space. The 327.56 lb unit includes mounting hardware for both 4-post rack enclosures and tower stands, providing installation flexibility. The chassis is engineered for data center environments with a maximum operating temperature of 104°F (40°C).
The physical profile is practical for deployment planning because the dimensions and weight are clearly defined: 31" (787.40 mm), 26" (660.40 mm), 41" (1041.40 mm), 327.56 lb (148578.72 g). This helps confirm rack, shelf, desk, or cabinet fit before installation.
- Width
- 26" (660.40 mm)
- Depth
- 41" (1041.40 mm)
- Height
- 31" (787.40 mm)
- Weight
- 327.56 lb (148578.72 g)
What's in the Box
The package includes everything needed for installation and operation.
Highlights
- 10kVA/9000W double conversion online UPS with 0 ns transfer time
- Pure sine wave output at 220V/230V/240V AC for sensitive equipment
- 6U rack/tower compatible chassis with flexible mounting options
- Hot-swappable battery modules for maintenance without downtime
- 4.3 minutes runtime at full load, 12.5 minutes at half load
- SNMP manageable with USB, RS232, and EPO ports
- Comprehensive status indicators with LED and LCD displays
- Includes PowerAlert software for centralized monitoring
- 6-year battery design life for reduced maintenance costs
- 2-year limited warranty with full manufacturer support
Specifications
| Specifications | |
|---|---|
| Manufacturer | Eaton Corporation |
| Manufacturer Part Number | SU10KRT3UHV |
| Brand Name | Tripp Lite series |
| Product Line | SmartOnline |
| Product Name | SmartOnline SU10KRT3UHV UPS |
| Product Type | Double Conversion Online UPS |
| Technical Information | |
| Transfer Time | 0 ns |
| Power Description | |
| Load Capacity (VA) | 10 kVA |
| Load Capacity (Watt) | 9 kW |
| Output Voltage | 240 V AC,220 V AC,230 V AC |
| Waveform Type | Sine Wave |
| Management | |
| Network Management | SNMP Manageable |
| Alarm | On Battery,Low Battery,Overload,UPS Fault,Remote Shutdown |
| Controls/Indicators | |
| Status Indicators | 6 LED DISPLAY: line power, bypass, inverter, charger, output AC and battery operation. SELECTABLE LCD DISPLAY: input/output voltage, Hz, battery voltage and charge level and detailed warnings regarding all major UPS functions |
| Battery Information | |
| Battery Chemistry | Lead Acid |
| Backup/Run Time (Full Load) | 4.30 Minute |
| Backup/Run Time (Half Load) | 12.50 Minute |
| Battery Life | 6 Year |
| Hot Swappable | Yes |
| Typical Battery Recharge Time | 4 Hour |
| Environmental Conditions | |
| Maximum Operating Temperature | 104°F (40°C) |
| Physical Characteristics | |
| Height | 31" (787.40 mm) |
| Width | 26" (660.40 mm) |
| Depth | 41" (1041.40 mm) |
| Rack Height | 6U |
| Weight (Approximate) | 327.56 lb (148578.72 g) |
| Miscellaneous | |
| Package Contents | SmartOnline SU10KRT3UHV UPS SU10KRT3UHV Rack-Tower UPS System with hardwire distribution module and 1 BP240V10RT3U battery pack PowerAlert Software and cabling Mounting hardware for 4 post rack enclosures/tower stands Instruction manual with warranty information |
| Country of Origin | China |
| Warranty | |
| Limited Warranty | 2 Year |
User Manual
FAQ
What is the power capacity of this UPS?
The Tripp Lite SU10KRT3UHV provides 10 kVA (10,000 VA) and 9,000 watts of power capacity. This supports substantial server, storage, and networking equipment loads in data center and server room environments.
How long does the battery last during a power outage?
At full load, the UPS provides 4.3 minutes of runtime. At half load, runtime extends to 12.5 minutes. The actual runtime depends on the connected equipment's power draw, with lighter loads achieving longer backup periods.
Is this UPS rack-mountable or tower-style?
This unit is both rack and tower compatible. It occupies 6U of rack space and includes mounting hardware for 4-post rack enclosures as well as tower stands, providing installation flexibility for different environments.
Are the batteries hot-swappable?
Yes, the battery modules are hot-swappable. This allows replacement without powering down connected equipment, ensuring continuous operation during maintenance and reducing system downtime.
What management options are available?
The UPS supports SNMP management for network monitoring, along with USB and RS232 local connections. It includes PowerAlert software and supports contact-closure card options for integration with building management systems.
What output voltage does this UPS provide?
The unit delivers pure sine wave output at selectable voltages of 220V, 230V, and 240V AC. This flexibility accommodates different power standards and equipment requirements across various geographical regions.
What power capacity is listed for this UPS?
The listed power specification is 10 kVA, which helps position the unit for the right load level and installation role.
What voltage details are listed?
The listed power specification is 240 V AC,220 V AC,230 V AC, which helps position the unit for the right load level and installation role.