Technical Overview
Engineered for consistent performance, this UPS operates with a line-interactive topology that regulates voltage without switching to battery during minor fluctuations. The 12V lead-acid battery with 9000mAh capacity supports hot-swappable replacement, reducing downtime during maintenance.
Advanced protection features include surge suppression, overload protection, and a circuit breaker to safeguard connected devices. The RJ-45 dataline protection extends surge protection to network connections, while the input voltage range of 89-145V AC accommodates varying power conditions.
This section brings together practical product details such as Plug/Connector Type, Receptacle Type, Receptacle Detail, Load Capacity (VA), so buyers can judge configuration, deployment fit, and day-to-day suitability with less guesswork.
A strong technical summary explains how the product's interfaces, hardware profile, and operating characteristics work together in real deployment. Buyers often need this context to confirm compatibility with existing devices, expected performance in daily use, and whether installation will be straightforward for IT staff or end users.
Key Product Advantages
This UPS combines robust power protection with operational clarity through its intuitive LED status system. Indicators provide real-time feedback on adoption status, battery mode, firmware updates, and warnings, enabling quick troubleshooting without external tools.
Flexible Deployment
The desktop/tower form factor allows placement beside workstations or in server closets, supported by a compact footprint that conserves space.
- Desktop or tower orientation
- Stable base design
- No rack rails required
Environmental Resilience
Rated for operation from 32°F to 104°F with storage tolerance from -4°F to 122°F, ensuring reliability across typical office and light industrial environments.
- Wide temperature range
- High-altitude capable
- Lead-acid battery chemistry
Deployment / Use Cases
Ideal for small office networks, the UPS-TOWER-US provides sufficient runtime to gracefully shut down connected servers, switches, and routers during extended outages. The 2-minute full-load backup allows time to save work and power down equipment safely.
In retail or point-of-sale environments, it keeps transaction systems operational through brief power interruptions, preventing data loss and downtime. The surge-only outlets can power less critical peripherals while reserving battery-backed outlets for essential devices.
Network Infrastructure Protection
Power networking equipment like switches, routers, and access points with battery-backed outlets while using surge-only outlets for monitors or printers.
- RJ-45 dataline protection
- 10 outlets total
- 120V AC output
Workstation Backup
Support desktop computers, external storage, and displays with enough runtime to complete shutdown procedures during unexpected power loss.
- 600W capacity
- Simulated sine wave
- 5 battery/surge outlets
Physical Profile
Measuring 11.34" H × 3.90" W × 11.04" D (288 × 99 × 280.5 mm) and weighing 18.01 lb (8.17 kg), this UPS maintains a compact footprint suitable for desktop or floor placement. The vertical tower design minimizes desk space usage while providing stable support for the internal battery and electronics.
- Width
- 3.90" (99 mm)
- Depth
- 11.04" (280.50 mm)
- Height
- 11.34" (288 mm)
- Weight
- 18.01 lb (8170 g)
- Length
- 5.9 ft (1.80 m)
Highlights
- 1 kVA / 600W load capacity for reliable backup power
- 10 total outlets: 5 battery/surge plus 5 surge-only
- 2-minute full-load runtime, 7-minute half-load runtime
- 120V AC input and output with simulated sine wave
- Hot-swappable 12V lead-acid battery with 8-hour recharge
- Line-interactive topology with 10ms transfer time
- RJ-45 dataline protection for network equipment
- LED status indicators for clear operational feedback
- Desktop/tower form factor for flexible placement
- NDAA compliant for government and enterprise use
Specifications
| Specifications | |
|---|---|
| Manufacturer | Ubiquiti Inc. |
| Manufacturer Part Number | UPS-TOWER-US |
| Brand Name | Ubiquiti |
| Product Name | 1000VA Desktop/Tower UPS |
| Product Type | Line-interactive UPS |
| Technical Information | |
| Plug/Connector Type | NEMA 5-15P |
| Receptacle Type | NEMA 5-15R,RJ-45 |
| Receptacle Detail | 10 x NEMA 5-15R,2 x RJ-45 |
| Number of Battery & Surge Outlets | 5 |
| Number of Surge-only Outlets | 5 |
| Dataline Protection | RJ-45 |
| Overload Protection | Yes |
| Cord Length | 5.9 ft (1.80 m) |
| Transfer Time | 10 ms |
| Surge Suppression | Yes |
| Power Description | |
| Load Capacity (VA) | 1 kVA |
| Load Capacity (Watt) | 600 W |
| Input Voltage | 120 V AC |
| Input Voltage Range | 89 V AC - 145 V AC |
| Input Current | 12 A |
| Output Voltage | 120 V AC |
| Input Frequency | 50 Hz,60 Hz |
| Output Frequency | 50 Hz,60 Hz |
| Waveform Type | Simulated Sine Wave |
| Circuit Breaker | Yes |
| Controls/Indicators | |
| Status Indicators | LEDs: Off: device not turned on Flashing white: initializing / factory default Steady white: waiting for adoption Steady blue: device adoption and working Flashing blue: battery mode Alternating white/blue: firmware upgrading Rapid flashing blue: locate Steady red: warning Flashing red: low battery |
| Interfaces/Ports | |
| Network (RJ-45) | Yes |
| Battery Information | |
| Number of Batteries | 1 |
| Battery Chemistry | Lead Acid |
| Battery Size | 12V |
| Battery Capacity | 9000 mAh |
| Backup/Run Time (Full Load) | 2 Minute |
| Backup/Run Time (Half Load) | 7 Minute |
| Hot Swappable | Yes |
| Typical Battery Recharge Time | 8 Hour |
| Environmental Conditions | |
| Maximum Operating Elevation | 9842.52 ft (3000000 mm) |
| Storage Temperature | -4°F (-20°C) - 122°F (50°C) |
| Minimum Operating Temperature | 32°F (0°C) |
| Maximum Operating Temperature | 104°F (40°C) |
| Physical Characteristics | |
| Height | 11.34" (288 mm) |
| Width | 3.90" (99 mm) |
| Depth | 11.04" (280.50 mm) |
| Form Factor | Desktop/Tower |
| Weight (Approximate) | 18.01 lb (8170 g) |
| Miscellaneous | |
| NDAA Compliant | Yes |
FAQ
What is the power capacity of this UPS?
The Ubiquiti UPS-TOWER-US provides 1 kVA (1000VA) apparent power and 600W real power capacity. This rating determines how much equipment it can support during an outage, suitable for small servers, networking gear, or multiple workstations.
How many outlets does this UPS have and what types?
This unit features 10 total outlets: 5 offer both battery backup and surge protection, while 5 provide surge protection only. The receptacles are NEMA 5-15R type, plus two RJ-45 ports for dataline protection of network connections.
What is the backup runtime at full and half load?
At full 600W load, the UPS provides approximately 2 minutes of runtime. At half load (300W), runtime extends to about 7 minutes. These times allow for safe shutdown of connected equipment during power interruptions.
What type of waveform does this UPS produce?
This UPS generates a simulated sine wave output, which is compatible with most modern electronics including computers, networking equipment, and peripherals. It provides cleaner power than stepped approximations while being more cost-effective than pure sine wave units.
Can the battery be replaced without powering down the UPS?
Yes, the hot-swappable battery design allows replacement while the UPS remains operational. The 12V lead-acid battery typically recharges within 8 hours after being depleted, minimizing downtime during maintenance.
What input voltage range does this UPS accept?
The UPS accepts input voltage from 89V AC to 145V AC at 50/60Hz, accommodating typical North American power variations. It outputs a regulated 120V AC to connected equipment, providing protection against brownouts and overvoltage conditions.
What power capacity is listed for this UPS?
The listed power specification is 1 kVA, which helps position the unit for the right load level and installation role.
How many outlets are available?