Shipping included*
Exclusions
Additional shipping fees may apply in rare circumstances for deliveries outside standard service areas. In most cases, this only potentially affects shipments to the Northwest Territories and Yukon, as well as certain heavy or oversized items.
Ubiquiti UPS-Tower 1000VA Desktop/Tower UPS - 1 kVA / 600W - 120V AC - 10 Outlets - Simulated Sine Wave
Business volume discounts
Technical guidance
Preparation & staging
QC · ON · AB · BC
Product Features
Technical Overview
This line-interactive UPS operates with a 10 ms transfer time, swiftly switching to battery power during voltage sags or blackouts. The unit supports input voltages from 89V AC to 145V AC and handles frequencies of 50 Hz or 60 Hz, accommodating various power conditions.
Power management features include surge suppression on all outlets, overload protection, and a built-in circuit breaker for safety. The RJ-45 dataline protection safeguards connected network equipment from power surges transmitted through Ethernet cables.
This section brings together practical product details such as Plug/Connector Type, Receptacle Type, Receptacle Detail, Load Capacity (VA), so buyers can judge configuration, deployment fit, and day-to-day suitability with less guesswork.
A strong technical summary explains how the product's interfaces, hardware profile, and operating characteristics work together in real deployment. Buyers often need this context to confirm compatibility with existing devices, expected performance in daily use, and whether installation will be straightforward for IT staff or end users.
Key Product Advantages
The UPS-Tower combines substantial power capacity with intelligent features for comprehensive protection. Its hot-swappable lead-acid battery allows for maintenance without downtime, while detailed LED status indicators provide clear operational feedback.
These strengths make the product easier to deploy and manage in real environments, especially where reliability, usability, and day-to-day operational continuity matter. Notable benefits include Intelligent Status Monitoring, Comprehensive Outlet Protection.
Intelligent Status Monitoring
Multi-color LEDs indicate device status including initialization, adoption, battery mode, firmware updates, and warnings, enabling quick troubleshooting.
- Steady blue: normal operation
- Flashing blue: battery mode
- Flashing red: low battery
Comprehensive Outlet Protection
Ten total outlets provide flexible power distribution with five offering battery backup and surge protection plus five surge-only outlets for non-critical devices.
- 5 battery & surge outlets
- 5 surge-only outlets
- NEMA 5-15R connectors
Deployment / Use Cases
This 1000VA UPS is ideal for protecting small business infrastructure including networking equipment, desktop computers, and point-of-sale systems. The desktop/tower design suits office environments where rack mounting isn't required but reliable power backup is essential.
Typical deployments include supporting network switches, routers, and servers during brief outages, providing enough runtime for graceful shutdowns or continued operation through short interruptions. The unit's 2-minute runtime at full load offers sufficient time to save work and properly shut down connected equipment.
Small Office Network Protection
Safeguard routers, switches, and modems to maintain network connectivity during power fluctuations, preventing data loss and service interruptions.
Workstation Backup Solution
Protect desktop computers and peripherals, allowing time to save documents and perform proper shutdowns when primary power fails.
Physical Profile
With dimensions of 11.34" high, 3.90" wide, and 11.04" deep, the UPS-Tower presents a compact footprint suitable for placement under desks, on shelves, or beside equipment. The 18-pound weight provides stability while remaining portable enough for repositioning as needed.
The unit operates effectively in environments from 32°F to 104°F (0°C to 40°C) and can be stored in temperatures ranging from -4°F to 122°F (-20°C to 50°C). Its maximum operating elevation of 9,842 feet ensures reliable performance in various geographical locations.
- Width
- 3.90" (99 mm)
- Depth
- 11.04" (280.50 mm)
- Height
- 11.34" (288 mm)
- Weight
- 18.01 lb (8170 g)
- Length
- 5.9 ft (1.80 m)
Highlights
- 1 kVA / 600W power capacity for reliable equipment protection
- Desktop/tower form factor with flexible placement options
- 10 total outlets (5 battery backup + 5 surge only)
- 2-minute runtime at full load for graceful shutdowns
- 8-hour battery recharge time for quick recovery
- Simulated sine wave output compatible with most equipment
- Hot-swappable lead-acid battery for maintenance without downtime
- RJ-45 dataline protection for network equipment safety
- LED status indicators for clear operational feedback
- NDAA compliant for use in sensitive environments
Specifications
| Specifications | |
|---|---|
| Manufacturer | Ubiquiti Inc. |
| Manufacturer Part Number | UPS-Tower |
| Brand Name | Ubiquiti |
| Product Name | 1000VA Desktop/Tower UPS |
| Product Type | Line-interactive UPS |
| Technical Information | |
| Plug/Connector Type | NEMA 5-15P |
| Receptacle Type | NEMA 5-15R,RJ-45 |
| Receptacle Detail | 10 x NEMA 5-15R,2 x RJ-45 |
| Number of Battery & Surge Outlets | 5 |
| Number of Surge-only Outlets | 5 |
| Dataline Protection | RJ-45 |
| Overload Protection | Yes |
| Cord Length | 5.9 ft (1.80 m) |
| Transfer Time | 10 ms |
| Surge Suppression | Yes |
| Power Description | |
| Load Capacity (VA) | 1 kVA |
| Load Capacity (Watt) | 600 W |
| Input Voltage | 120 V AC |
| Input Voltage Range | 89 V AC - 145 V AC |
| Input Current | 12 A |
| Output Voltage | 120 V AC |
| Input Frequency | 50 Hz,60 Hz |
| Output Frequency | 50 Hz,60 Hz |
| Waveform Type | Simulated Sine Wave |
| Circuit Breaker | Yes |
| Controls/Indicators | |
| Status Indicators | LEDs: Off: device not turned on Flashing white: initializing / factory default Steady white: waiting for adoption Steady blue: device adoption and working Flashing blue: battery mode Alternating white/blue: firmware upgrading Rapid flashing blue: locate Steady red: warning Flashing red: low battery |
| Interfaces/Ports | |
| Network (RJ-45) | Yes |
| Battery Information | |
| Number of Batteries | 1 |
| Battery Chemistry | Lead Acid |
| Battery Size | 12V |
| Battery Capacity | 9000 mAh |
| Backup/Run Time (Full Load) | 2 Minute |
| Backup/Run Time (Half Load) | 7 Minute |
| Hot Swappable | Yes |
| Typical Battery Recharge Time | 8 Hour |
| Environmental Conditions | |
| Maximum Operating Elevation | 9842.52 ft (3000000 mm) |
| Storage Temperature | -4°F (-20°C) - 122°F (50°C) |
| Minimum Operating Temperature | 32°F (0°C) |
| Maximum Operating Temperature | 104°F (40°C) |
| Physical Characteristics | |
| Height | 11.34" (288 mm) |
| Width | 3.90" (99 mm) |
| Depth | 11.04" (280.50 mm) |
| Form Factor | Desktop/Tower |
| Weight (Approximate) | 18.01 lb (8170 g) |
| Miscellaneous | |
| NDAA Compliant | Yes |
FAQ
What is the power capacity of this UPS?
The Ubiquiti UPS-Tower provides 1 kVA (1000VA) apparent power and 600W real power capacity. This rating determines how much equipment the UPS can support during a power outage, making it suitable for small office setups, networking gear, or desktop workstations.
How long does the battery backup last during an outage?
At full 600W load, the UPS provides approximately 2 minutes of runtime. At half load (300W), runtime extends to about 7 minutes. These times allow for saving work and performing proper shutdowns or maintaining operation through brief power interruptions.
What types of outlets does this UPS have?
The unit features 10 total NEMA 5-15R outlets: five provide both battery backup and surge protection for critical equipment, while five offer surge protection only for non-essential devices. This configuration allows flexible power distribution based on equipment importance.
What is the recharge time for the battery?
The lead-acid battery typically recharges within 8 hours after being depleted. This recharge time ensures the UPS is ready for subsequent outages and maintains optimal battery health through proper charging cycles.
Can the battery be replaced without downtime?
Yes, the UPS features hot-swappable battery capability. This allows you to replace the 12V lead-acid battery while the unit continues to provide power to connected equipment, ensuring uninterrupted protection during maintenance.
What power waveform does this UPS produce?
The UPS-Tower generates simulated sine wave output. This waveform is compatible with most computer and networking equipment, providing clean power during battery operation while maintaining affordability compared to pure sine wave units.
What power capacity is listed for this UPS?
The listed power specification is 1 kVA, which helps position the unit for the right load level and installation role.
How many outlets are available?
The product includes 5, which helps buyers understand how many connected devices it can support in its intended deployment.