V7 UPS2URM3000DC-NC-1N On-Line 3000VA/2740W 2U Rack/Tower UPS - 120V Pure Sine Wave - 6 Outlets
Business volume discounts
Technical guidance
Preparation & staging
QC · ON · AB · BC
Product Features
Technical Overview
This online UPS employs double-conversion technology, where incoming AC power is converted to DC, then back to clean AC, providing complete isolation from utility power anomalies. It delivers 3 kVA (3000VA) and 2.74 kW of capacity, with an input voltage of 120V AC and a broad output range adjustable from 100V to 127V AC. The pure sine wave output ensures compatibility with sensitive active PFC power supplies found in servers, storage, and networking gear.
Battery backup is provided by six sealed lead-acid 12V batteries with a total capacity of 9000 mAh. At full load, the system delivers 2.6 minutes of runtime, extending to 10 minutes at half load. The batteries recharge within 3 hours after a discharge event. An 82.1V DC system voltage and built-in overload protection safeguard connected devices.
Key Product Advantages
The UPS2URM3000DC-NC-1N combines high-capacity power protection with versatile deployment options, making it a robust choice for demanding environments. Its online double-conversion topology guarantees zero transfer time, eliminating any gap in power delivery during outages or fluctuations.
Comprehensive Power Management
Smart RS-232/USB and SNMP connectivity enable remote monitoring and control, while the LCD displays real-time metrics for AC/battery mode, load level, input/output voltage, and fault conditions. An EPO port allows for emergency shutdown integration.
- LCD status display
- SNMP/RS-232/USB management
- EPO port for safety
Enhanced Protection Features
Beyond battery backup, the unit includes dataline protection for RJ-11/RJ-45 connections, safeguarding network and phone lines from surges. Its high efficiency is reflected in a 0.99 input power factor and 0.9 output power factor.
- RJ-11/RJ-45 dataline protection
- High power factor efficiency
- Overload and fault alarms
Deployment / Use Cases
This UPS is engineered for environments where uptime is non-negotiable. Its 3000VA capacity and pure sine wave output make it suitable for protecting server racks, network switches, storage arrays, and telecom equipment in data centers, branch offices, and industrial settings.
The wide input voltage range and robust design support deployment in areas with unstable grid power, such as manufacturing floors, healthcare facilities, and retail locations. The rack/tower flexibility allows IT teams to standardize on a single model for both rack-mounted and floor-standing applications.
Server Room & Network Closet
Provides reliable backup for critical servers, switches, and routers, ensuring network continuity during power events. The 2U form factor fits standard racks without consuming excessive space.
Edge Computing & Industrial Automation
Supports remote or harsh environments where power quality may be inconsistent, protecting automation controllers, sensors, and edge servers from outages and surges.
Physical Profile
Housed in a black chassis, the UPS measures 3.39" (86.20 mm) in height, 17.24" (438 mm) in width, and 24.80" (630 mm) in depth, corresponding to a standard 2U rack height. It weighs approximately 59.96 lb (27.2 kg), with mounting rails and tower feet included for flexible installation. The design prioritizes efficient cooling and serviceability, operating within a temperature range up to 104°F (40°C) and 20-95% humidity.
- Width
- 17.24" (438 mm)
- Height
- 3.39" (86.20 mm)
- Weight
- 50 dB(A)
- Length
- 24.80" (630 mm)
What's in the Box
The package includes all necessary components for immediate deployment, whether rack-mounted or used as a tower unit.
Highlights
- 3000VA/2740W double-conversion online UPS with pure sine wave output
- 2U rack-mountable design with included tower feet for flexible deployment
- Zero transfer time ensures uninterrupted power during outages
- 6 x NEMA 5-15/20R and 1 x NEMA L5-30R outlets for versatile connectivity
- 2.6-minute full-load runtime and 10-minute half-load runtime
- Smart RS-232/USB and SNMP management for remote monitoring
- Wide input voltage range from 55V to 150V AC
- LCD display shows real-time status and system alerts
- Includes dataline protection for RJ-11/RJ-45 connections
- 3-year limited warranty with 1-year battery coverage
Specifications
| Specifications | |
|---|---|
| Manufacturer | V7 |
| Manufacturer Part Number | UPS2URM3000DC-NC-1N |
| Brand Name | V7 |
| Product Series | On-Line |
| Product Model | UPS2URM3000DC-NC-1N |
| Product Name | On-Line UPS2URM3000DC-NC-1N 3000VA Rack-mountable UPS |
| Product Type | Double Conversion Online UPS |
| Technical Information | |
| Plug/Connector Type | NEMA L5-30P |
| Receptacle Type | NEMA 5-15/20R,NEMA L5-30R |
| Receptacle Detail | 6 x NEMA 5-15/20R,1 x NEMA L5-30R |
| Dataline Protection | RJ-11/RJ-45 |
| Overload Protection | Yes |
| Transfer Time | 0 ns |
| Phase | Single Phase |
| Application/Usage | Server Room,Network Closet,Edge Computing,Healthcare,Finance,Manufacturing,Industrial Automation System,Retail |
| Power Description | |
| Load Capacity (VA) | 3 kVA |
| Load Capacity (Watt) | 2.74 kW |
| Input Voltage | 120 V AC |
| Input Voltage Range | 55 V AC - 150 V AC,80 V AC - 150 V AC |
| Output Voltage | 100 V AC,110 V AC,115 V AC,120 V AC,127 V AC |
| Input Frequency | 70 Hz |
| Output Frequency | 60 Hz |
| Waveform Type | Pure Sine Wave |
| Surge Energy Rating | 720 J |
| Input Power Factor | 0.99 |
| Output Power Factor | 0.9 |
| Display & Graphics | |
| Display | LCD |
| Management | |
| Network Management | Smart RS-232/USB,SNMP |
| Alarm | Battery Mode,Low Battery,Overload,Fault |
| Controls/Indicators | |
| Status Indicators | LCD Display: AC Mode Battery Mode Load Level Battery Level Input Voltage Output Voltage Overload Fault Low Battery |
| Interfaces/Ports | |
| USB | Yes |
| EPO Port | Yes |
| Battery Information | |
| DC System Voltage | 82.1 V DC |
| Number of Batteries | 6 |
| Battery Characteristics | Sealed |
| Battery Chemistry | Lead Acid |
| Battery Size | 12V |
| Battery Capacity | 9000 mAh |
| Backup/Run Time (Full Load) | 2.60 Minute |
| Backup/Run Time (Half Load) | 10 Minute |
| Typical Battery Recharge Time | 3 Hour |
| Environmental Conditions | |
| Operating Humidity | 20% - 95% |
| Maximum Operating Temperature | 104°F (40°C) |
| Sound Emission (A-Weighted) | 50 dB(A) |
| Physical Characteristics | |
| Product Color | Black |
| Height | 3.39" (86.20 mm) |
| Width | 17.24" (438 mm) |
| Length | 24.80" (630 mm) |
| Rack Height | 2U |
| Form Factor | Rack-mountable |
| Weight (Approximate) | 59.96 lb (27197.40 g) |
| Miscellaneous | |
| Package Contents | On-Line UPS2URM3000DC-NC-1N 3000VA Rack-mountable UPS US NEMA 2.4m 5-15P Power Cable 1.5m USB Cable Mounting Rails Tower Feet User's Guide Warranty & Compliance |
| Energy Star | Yes |
| Country of Origin | Taiwan |
| TAA Compliant | Yes |
| Environmentally Friendly | Yes |
| Environmental Compliance | Restriction of Hazardous Substances (RoHS),Registration, Evaluation, Authorization and Restriction of Chemicals (REACH) |
| Warranty | |
| Limited Warranty | 3 Year |
| Additional Warranty Information | 3 Year (1 Year Battery) |
User Manual
FAQ
What is the power capacity of this V7 UPS?
The V7 UPS2URM3000DC-NC-1N provides 3000VA (3 kVA) and 2740W of power capacity. This double-conversion online UPS supports critical equipment like servers, network switches, and storage arrays, delivering clean, regulated power with pure sine wave output.
How long does the battery last during a power outage?
At full load, the battery runtime is 2.6 minutes, extending to 10 minutes at half load. The system uses six sealed lead-acid 12V batteries with a total capacity of 9000 mAh, and it typically recharges within 3 hours after a discharge event.
Can this UPS be installed in a server rack?
Yes, this UPS is designed for 2U rack mounting with included mounting rails. It also comes with tower feet, allowing flexible deployment as a standalone unit. The black chassis measures 3.39" high, 17.24" wide, and 24.80" deep, fitting standard 19-inch racks.
What types of outlets does the UPS have?
The unit includes six NEMA 5-15/20R outlets and one NEMA L5-30R outlet, providing versatile connectivity for various devices. The input plug is a NEMA L5-30P, and it supports a 120V AC input voltage with a wide range from 55V to 150V AC.
Does this UPS support remote management?
Yes, it features smart RS-232/USB and SNMP connectivity for remote monitoring and control. The LCD display provides real-time status on AC/battery mode, load level, battery level, input/output voltage, and fault conditions, with alarms for battery mode, low battery, overload, and faults.
What is the warranty coverage for this UPS?
The UPS comes with a 3-year limited warranty, including 1-year coverage for the batteries. It is Energy Star certified, TAA compliant, and meets environmental standards such as RoHS and REACH, with a country of origin listed as Taiwan.
What power capacity is listed for this UPS?
The listed power specification is 3 kVA, which helps position the unit for the right load level and installation role.
What voltage details are listed?
The listed power specification is 120 V AC, which helps position the unit for the right load level and installation role.