Shipping included*
Exclusions
Additional shipping fees may apply in rare circumstances for deliveries outside standard service areas. In most cases, this only potentially affects shipments to the Northwest Territories and Yukon, as well as certain heavy or oversized items.
VERTIV VP6N52A0 Geist rPDU MNR5MDR6-12CF18-5CS15A0H10-S Monitored 12-Outlet PDU - 3P+E CA - 14. 4 kW - 12 x C13/C19 - 120/230V AC - 2U Rack-Mount
Business volume discounts
Technical guidance
Preparation & staging
QC · ON · AB · BC
Product Features
Technical Overview
This monitored PDU operates with three-phase power, accepting input voltages of 120 V AC or 230 V AC within ranges of 100-120 V AC and 200-240 V AC. It delivers 208 V AC output with a 50 A input current at 60 Hz frequency, supporting a maximum load of 14.40 kW. The unit features dual-pole overcurrent protection and includes both LED and touch screen displays for local status monitoring.
Network connectivity is provided through an RJ-45 port, enabling remote management via multiple protocols including DHCP, HTTP, HTTPS, IPv4, IPv6, SNMP v1/v2c/v3, SSH, SMTP, Syslog, and Modbus TCP. The management system supports CSV and JSON data logging with API access for integration into existing monitoring solutions. This technical architecture allows for real-time monitoring of voltage, frequency, and load levels across all three phases.
Key Product Advantages
This Vertiv Geist rPDU combines high power capacity with intelligent monitoring features that provide significant advantages for IT infrastructure management. The ability to remotely monitor single- or three-phase voltage, frequency, and load levels enables proactive power management and helps prevent downtime through early detection of power anomalies.
Comprehensive Monitoring
Remote monitoring capabilities allow IT staff to track power consumption patterns, identify potential issues before they cause outages, and optimize power distribution across connected equipment.
- Real-time voltage and frequency monitoring
- Load level tracking across all outlets
- Historical data logging for analysis
Flexible Connectivity
With 12 combination C13/C19 outlets, this PDU accommodates both standard and high-power equipment, eliminating the need for multiple PDUs with different receptacle types.
- Mixed equipment support in single unit
- Reduced cable clutter and complexity
- Simplified power distribution planning
Robust Protection
Double-pole overcurrent protection safeguards connected equipment from power surges and electrical faults, while the durable construction ensures reliable operation in demanding environments.
- Equipment protection from electrical faults
- Durable powder coat finish
- High-temperature operation to 140°F (60°C)
Deployment / Use Cases
This monitored PDU is specifically designed for IT equipment deployment in data centers, server rooms, and network closets where reliable power distribution and monitoring are critical. The 14.4 kW capacity and three-phase power support make it ideal for high-density server racks, storage arrays, and networking equipment that require substantial power resources.
The combination of rack-mount and recess-mount options provides installation flexibility for various cabinet configurations. Network management capabilities allow integration with existing data center infrastructure management (DCIM) systems, enabling centralized monitoring of power consumption across multiple racks and facilities. This PDU is particularly valuable for organizations implementing power usage effectiveness (PUE) optimization strategies or requiring detailed power reporting for capacity planning.
Data Center Server Racks
Support high-density server deployments with three-phase power distribution and remote monitoring for capacity management and fault detection.
Network Equipment Closets
Provide reliable power to switches, routers, and other networking gear while monitoring power quality and consumption patterns.
Physical Profile
This PDU features a compact 2U rack-mount design with dimensions of 3.39" (86.11 mm) height, 17" (431.80 mm) width, and 12" (304.80 mm) depth, optimized for standard 19-inch equipment racks. The horizontal mounting orientation and recess-mount capability provide installation flexibility for various cabinet configurations. The black powder coat finish offers both aesthetic appeal and corrosion resistance, while the 10-foot power cord provides adequate reach for most rack installations.
- Width
- 17" (431.80 mm)
- Depth
- 12" (304.80 mm)
- Height
- 2U
- Length
- 10 ft (3.05 m)
Highlights
- 14.4 kW load capacity for high-power equipment support
- 12 combination C13/C19 outlets for flexible connectivity
- Three-phase power with 3P+E CA plug configuration
- Remote monitoring of voltage, frequency, and load levels
- Network management via RJ-45 with multiple protocol support
- 2U rack-mount design with horizontal orientation
- Double-pole overcurrent protection for equipment safety
- LED and touch screen displays for local status monitoring
- Maximum operating temperature of 140°F (60°C)
- 5-year limited warranty with registration
Specifications
| Specifications | |
|---|---|
| Manufacturer | Vertiv |
| Manufacturer Part Number | VP6N52A0 |
| Brand Name | Vertiv Geist |
| Product Series | rPDU |
| Product Model | MNR5MDR6-12CF18-5CS15A0H10-S |
| Product Name | rPDU MNR5MDR6-12CF18-5CS15A0H10-S 12-Outlets PDU |
| Product Type | PDU |
| Technical Information | |
| PDU Type | Monitored |
| Phase | Three Phase |
| Plug/Connector Type | 3P+E CA |
| Plug/Connector Detail | 1 x 3P+E CA |
| Receptacle Type | Combination C13/C19 |
| Receptacle Detail | 12 x Combination C13/C19 |
| Protection Type | Overcurrent Protection,Double Pole |
| Features | LED Display,Touch Screen Display |
| Load Capacity (Watt) | 14.40 kW |
| Power Description | |
| Input Voltage | 120 V AC,230 V AC |
| Input Voltage Range | 100 V AC - 120 V AC,200 V AC - 240 V AC |
| Output Voltage | 208 V AC |
| Power Rating (Watt) | 14.40 kW |
| Input Current | 50 A |
| Input Frequency | 60 Hz |
| Management | |
| Management | DHCP HTTP HTTPS IPv4 IPv6 LDAP NTP RADIUS RSTP SSH SMTP SNMP (v1/v2c/v3) Syslog TACACS+ Modbus TCP CSV datalog JSON API JSON datalog |
| Interfaces/Ports | |
| Network (RJ-45) | Yes |
| Physical Characteristics | |
| Color Family | Black |
| Product Color | Black Powder Coat |
| Mounting Orientation | Horizontal |
| Mount Type | Rack-mountable,Recess-mountable |
| Rack Height | 2U |
| Cord Length | 10 ft (3.05 m) |
| Height | 3.39" (86.11 mm) |
| Width | 17" (431.80 mm) |
| Depth | 12" (304.80 mm) |
| Environmental Conditions | |
| Maximum Operating Temperature | 140°F (60°C) |
| Miscellaneous | |
| Application/Usage | IT Equipment |
| Country of Origin | United States |
| TAA Compliant | Yes |
| Environmental Compliance | Restriction of Hazardous Substances (RoHS) |
| Warranty | |
| Limited Warranty | 5 Year |
| Additional Warranty Information | 5-year limited warranty if registered within 120 days of purchase, otherwise warranty defaults to 3 years |
User Manual
FAQ
What is the power capacity of this Vertiv Geist PDU?
This Vertiv Geist rPDU has a load capacity of 14.40 kW (14,400 watts), making it suitable for high-density server racks and equipment that require substantial power resources. The three-phase power distribution ensures efficient power delivery to connected devices while maintaining monitoring capabilities across all phases.
How many outlets does this PDU have and what types are they?
This PDU features 12 combination C13/C19 outlets, providing flexibility to connect both standard and high-power equipment. The combination receptacles accept either C13 or C19 plugs, eliminating the need for separate PDUs for different equipment types and simplifying cable management in rack environments.
What input voltages does this PDU support?
The PDU accepts input voltages of 120 V AC or 230 V AC, with operating ranges of 100-120 V AC and 200-240 V AC respectively. This dual-voltage capability provides installation flexibility in different electrical environments while delivering 208 V AC output to connected equipment.
How is this PDU mounted and what rack space does it require?
This PDU is designed for horizontal mounting in standard 19-inch equipment racks and requires 2U of rack space. It features both rack-mount and recess-mount options, providing installation flexibility for various cabinet configurations. The compact dimensions of 3.39" height, 17" width, and 12" depth optimize space utilization in crowded rack environments.
What management capabilities does this monitored PDU offer?
This monitored PDU provides comprehensive network management through an RJ-45 port supporting protocols including DHCP, HTTP, HTTPS, SNMP v1/v2c/v3, SSH, and Modbus TCP. It enables remote monitoring of single- or three-phase voltage, frequency, and load levels, with CSV and JSON data logging capabilities for integration into existing monitoring systems.
What protection features are included with this PDU?
The PDU includes double-pole overcurrent protection to safeguard connected equipment from electrical faults and power surges. This protection mechanism helps prevent damage to sensitive IT equipment while ensuring reliable power distribution. The unit is also RoHS compliant and operates at temperatures up to 140°F (60°C) for reliable performance in demanding environments.
What power capacity is listed for this UPS?
The listed power specification is 14.40 kW, which helps position the unit for the right load level and installation role.
What voltage details are listed?
The listed power specification is 120 V AC,230 V AC, which helps position the unit for the right load level and installation role.