Geist VP6N30AV rPDU Monitored Rack PDU - 36 Combination C13/C19 Outlets - 4. 90 kW - NEMA L6-30P - 230V AC - 0U Vertical Mount
Business volume discounts
Technical guidance
Preparation & staging
QC · ON · AB · BC
Product Features
Technical Overview
This monitored PDU operates with 230V AC input voltage within a 200-240V AC range, delivering 208V AC output at 30A input current and 60Hz frequency. The 4.90 kW power rating supports demanding IT loads while maintaining stable power distribution across all 36 outlets.
The unit incorporates both LED and touch screen displays for local monitoring, providing real-time visibility into power consumption and load status. Network connectivity enables remote management through multiple protocols including SNMP v1/v2c/v3, HTTP, HTTPS, SSH, and Modbus TCP for integration with existing monitoring systems.
This section brings together practical product details such as PDU Type, Plug/Connector Type, Plug/Connector Detail, Input Voltage, so buyers can judge configuration, deployment fit, and day-to-day suitability with less guesswork.
A strong technical summary explains how the product's interfaces, hardware profile, and operating characteristics work together in real deployment. Buyers often need this context to confirm compatibility with existing devices, expected performance in daily use, and whether installation will be straightforward for IT staff or end users.
Key Product Advantages
This Geist rPDU combines high-density power distribution with advanced monitoring capabilities, providing IT administrators with comprehensive power management tools in a zero-rack-unit form factor. The monitored functionality delivers proactive alerts before critical input sources become overloaded, preventing unexpected downtime.
High-Density Outlet Configuration
Thirty-six combination C13/C19 outlets maximize rack space utilization while providing compatibility with both standard and high-power equipment connections.
- Supports mixed C13 and C19 devices
- Eliminates need for adapter cables
- Optimizes rack power density
Comprehensive Network Management
Enterprise-grade management protocols enable integration with existing monitoring systems and provide multiple access methods for power monitoring and control.
- SNMP v1/v2c/v3 support
- SSH secure access
- Modbus TCP integration
- JSON/CSV data export
Robust Electrical Protection
Double-pole overcurrent protection safeguards connected equipment while maintaining power availability to unaffected outlets during fault conditions.
- Individual circuit protection
- Maintains uptime for healthy circuits
- Prevents cascading failures
Deployment / Use Cases
This monitored PDU is specifically designed for data center environments where precise power monitoring and high-density outlet configurations are essential. The vertical 0U mounting preserves valuable horizontal rack space while providing accessible power distribution along the full rack height.
Ideal for server racks, network cabinets, and storage arrays, this unit supports mixed IT equipment deployments through its combination outlet design. The monitoring capabilities make it particularly valuable for colocation facilities, enterprise data centers, and managed service providers requiring detailed power usage reporting and alerting.
Data Center Power Distribution
Deploy in server racks to power compute, storage, and networking equipment with real-time power monitoring and load balancing capabilities.
Managed Service Provider Environments
Utilize the comprehensive monitoring features to provide clients with detailed power usage reports and proactive outage prevention.
Physical Profile
The PDU features a compact 2-inch width and 2.60-inch depth profile that fits neatly in standard rack channels, with a 70-inch length providing full vertical coverage in standard 42U racks. The black powder coat finish offers durability and professional appearance, while the vertical mounting orientation maximizes airflow in densely populated racks.
- Width
- 2" (50.80 mm)
- Depth
- 2.60" (66.04 mm)
- Height
- 0U
- Length
- 10 ft (3.05 m)
What's in the Box
The package includes all necessary components for immediate deployment in standard rack environments.
Package contents include rPDU MNR5MGW1-36CF18-3TL6A0A10-S 36-Outlets PDU Vertical Mounting Bracket Kit, rPDU MNR5MGW1-36CF18-3TL6A0A10-S 36-Outlets PDU. These included items support setup, installation, and immediate deployment without needing to source the core bundled accessories separately.
Highlights
- 36 combination C13/C19 outlets for flexible equipment connectivity
- 4.90 kW power rating supports high-density IT loads
- Monitored PDU with LED and touch screen displays
- Vertical 0U rack mounting preserves horizontal space
- NEMA L6-30P input connector for 230V AC power sources
- Network management via SNMP, HTTP, SSH, and Modbus TCP
- Double-pole overcurrent protection for equipment safety
- Black powder coat finish for durable rack compatibility
- TAA compliant for government and educational deployments
- 5-year limited warranty with registration
Specifications
| Specifications | |
|---|---|
| Manufacturer | Vertiv |
| Manufacturer Part Number | VP6N30AV |
| Brand Name | Vertiv Geist |
| Product Series | rPDU |
| Product Model | MNR5MGW1-36CF18-3TL6A0A10-S |
| Product Name | rPDU MNR5MGW1-36CF18-3TL6A0A10-S 36-Outlets PDU |
| Product Type | PDU |
| Technical Information | |
| PDU Type | Monitored |
| Plug/Connector Type | NEMA L6-30P |
| Plug/Connector Detail | 1 x NEMA L6-30P |
| Receptacle Type | Combination C13/C19 |
| Receptacle Detail | 36 x Combination C13/C19 |
| Protection Type | Overcurrent Protection,Double Pole |
| Features | LED Display,Touch Screen Display |
| Load Capacity (Watt) | 4.90 kW |
| Power Description | |
| Input Voltage | 230 V AC |
| Input Voltage Range | 200 V AC - 240 V AC |
| Output Voltage | 208 V AC |
| Power Rating (Watt) | 4.90 kW |
| Input Current | 30 A |
| Input Frequency | 60 Hz |
| Management | |
| Management | DHCP HTTP HTTPS IPv4 IPv6 LDAP NTP RADIUS RSTP SSH SMTP SNMP (v1/v2c/v3) Syslog TACACS+ Modbus TCP CSV datalog JSON API JSON datalog |
| Interfaces/Ports | |
| Network (RJ-45) | Yes |
| Physical Characteristics | |
| Color Family | Black |
| Product Color | Black Powder Coat |
| Mounting Orientation | Vertical |
| Mount Type | Rack-mountable |
| Rack Height | 0U |
| Cord Length | 10 ft (3.05 m) |
| Width | 2" (50.80 mm) |
| Depth | 2.60" (66.04 mm) |
| Length | 70" (1778 mm) |
| Environmental Conditions | |
| Maximum Operating Temperature | 140°F (60°C) |
| Miscellaneous | |
| Package Contents | rPDU MNR5MGW1-36CF18-3TL6A0A10-S 36-Outlets PDU Vertical Mounting Bracket Kit |
| Application/Usage | IT Equipment |
| Country of Origin | United States |
| TAA Compliant | Yes |
| Environmental Compliance | Restriction of Hazardous Substances (RoHS) |
| Warranty | |
| Limited Warranty | 5 Year |
| Additional Warranty Information | 5-year limited warranty if registered within 120 days of purchase, otherwise warranty defaults to 3 years |
FAQ
What type of input connector does this PDU use?
This Geist rPDU uses a NEMA L6-30P input connector designed for 230V AC power sources. The connector provides a locking connection that prevents accidental disconnection in data center environments where power stability is critical.
How many outlets does this PDU provide and what types?
The unit provides 36 combination C13/C19 outlets, offering flexibility to connect both standard C13 and high-power C19 devices without requiring adapter cables. This mixed outlet configuration supports diverse IT equipment in rack environments.
What is the power capacity of this monitored PDU?
This PDU has a 4.90 kW power rating with 30A input current at 230V AC. The unit delivers 208V AC output voltage, making it suitable for powering multiple servers, networking devices, and storage systems in high-density rack deployments.
How is this PDU mounted in a rack?
The PDU is designed for vertical 0U rack mounting using the included bracket kit. Vertical mounting along the side of the rack preserves valuable horizontal U space for equipment while providing accessible power distribution along the full rack height.
What monitoring capabilities does this PDU offer?
This monitored PDU features both LED and touch screen displays for local monitoring, plus network connectivity for remote management. It supports multiple protocols including SNMP v1/v2c/v3, HTTP, HTTPS, SSH, and Modbus TCP for integration with data center monitoring systems.
What protection features are included with this PDU?
The unit includes double-pole overcurrent protection that safeguards connected equipment while maintaining power to unaffected outlets during fault conditions. This protection helps prevent cascading failures in critical IT environments.
What power capacity is listed for this UPS?
The listed power specification is 4.90 kW, which helps position the unit for the right load level and installation role.
What voltage details are listed?
The listed power specification is 230 V AC, which helps position the unit for the right load level and installation role.