Liebert PD3-006 ITA2 3-Phase Rack PDU with 6 NEMA L6-20R Outlets - Rack-Mountable Power Distribution Unit
Business volume discounts
Technical guidance
Preparation & staging
QC · ON · AB · BC
Product Features
Product Overview
The Liebert PD3-006 ITA2 3-Phase Rack PDU delivers reliable power distribution for data center and IT cabinet environments. This power distribution unit is engineered to streamline rack-level power management with a straightforward, rack-mountable design that integrates directly into standard server racks.
Featuring six NEMA L6-20R output receptacles, the PDU supports three-phase power input, making it suitable for high-density equipment deployments. Its construction focuses on operational simplicity and safety, with each receptacle individually protected by a dedicated circuit breaker to prevent overcurrent events and minimize downtime risks.
This section brings together practical product details such as Phase, Receptacle Type, Receptacle Detail, Mount Type, so buyers can judge configuration, deployment fit, and day-to-day suitability with less guesswork.
Technical Overview
This PDU operates on a three-phase power input, providing balanced power distribution across its six NEMA L6-20R output receptacles. The NEMA L6-20R receptacles are rated for 20-amp, 250-volt applications, commonly used for server, networking, and storage equipment in data centers.
Each output receptacle incorporates its own circuit breaker for overcurrent protection, isolating faults to individual outlets and maintaining power to unaffected equipment. The rack-mountable form factor allows for vertical or horizontal installation within standard 19-inch server racks, optimizing space utilization and cable management.
This section brings together practical product details such as Phase, Receptacle Type, Receptacle Detail, Mount Type, so buyers can judge configuration, deployment fit, and day-to-day suitability with less guesswork.
Key Product Advantages
Cost-Effective Installation
Eliminates the need for intermediate power strips or complex wiring by enabling direct connections from the PDU to rack-mounted equipment, reducing material and labor expenses.
- Simplifies rack power setup
- Minimizes wiring complexity
Enhanced Operational Safety
Each NEMA L6-20R receptacle is safeguarded by an individual circuit breaker, providing localized overcurrent protection to prevent equipment damage and reduce fire hazards.
- Isolates electrical faults
- Protects connected devices
User-Friendly Design
The straightforward rack-mountable installation and clearly labeled receptacles minimize setup errors and simplify maintenance, ensuring reliable power distribution with minimal training.
- Intuitive installation process
- Reduces human error
Deployment / Use Cases
The Liebert PD3-006 is ideal for data centers, server rooms, and network closets where reliable three-phase power distribution to rack-mounted equipment is required. Its six NEMA L6-20R outlets support high-power devices such as servers, storage arrays, and networking switches that demand stable, protected power inputs.
Common deployment scenarios include high-density server racks in enterprise data centers, telecommunications infrastructure cabinets, and broadcast equipment racks. The PDU's rack-mountable design integrates seamlessly with existing rack infrastructure, while its circuit breaker protection ensures operational continuity for critical IT loads.
Highlights
- Three-phase power input for balanced distribution
- Six NEMA L6-20R output receptacles
- Rack-mountable design for server cabinet integration
- Individual circuit breaker protection per receptacle
- Reduces installation costs with direct rack connections
- Minimizes human error through straightforward setup
- Suitable for high-power IT equipment
- Enhances operational safety in data center environments
Specifications
| Specifications | |
|---|---|
| Manufacturer | Vertiv |
| Manufacturer Part Number | PD3-006 |
| Brand Name | Vertiv Liebert |
| Product Model | 767041022513 |
| Product Name | ITA2 - 3 Phase POD with (6) L6-20R Output receptacles |
| Product Type | PDU |
| Technical Information | |
| Phase | Three Phase |
| Receptacle Type | NEMA L6-20R |
| Receptacle Detail | 6 x NEMA L6-20R |
| Physical Characteristics | |
| Mount Type | Rack-mountable |
FAQ
What type of power input does this PDU support?
The Liebert PD3-006 supports three-phase power input, providing balanced power distribution across its six output receptacles. Three-phase power is commonly used in data centers and commercial environments for efficient power delivery to high-density equipment.
How many output receptacles does this PDU have and what type are they?
This PDU features six NEMA L6-20R output receptacles. NEMA L6-20R receptacles are rated for 20-amp, 250-volt applications and are typically used for server, networking, and storage equipment in rack environments.
Is this PDU rack-mountable and how does it install?
Yes, the PDU is designed for rack mounting and can be installed vertically or horizontally in standard 19-inch server racks. This rack-mountable form factor allows for direct integration with rack infrastructure, simplifying cable management and optimizing space utilization.
What overcurrent protection does this PDU provide?
Each of the six NEMA L6-20R receptacles includes its own circuit breaker for individual overcurrent protection. This design isolates electrical faults to specific outlets, preventing damage to connected equipment and maintaining power to unaffected devices.
How does this PDU reduce installation costs?
The PDU reduces installation costs by enabling direct connections from the power source to rack-mounted equipment, eliminating the need for intermediate power strips or complex wiring setups. This streamlined approach minimizes material expenses and labor time during rack deployment.
What types of equipment is this PDU suitable for?
This PDU is suitable for high-power IT equipment including servers, storage arrays, networking switches, and other rack-mounted devices that require three-phase power with NEMA L6-20R connections. It's ideal for data centers, server rooms, and network closets with demanding power requirements.