APC by Schneider Electric NBES0308 APC NetBotz Leak Rope Sensor - 20 ft Orange Water Detection Cable for Data Centers
Business volume discounts
Technical guidance
Preparation & staging
QC · ON · AB · BC
Product Features
Technical Overview
This liquid leak sensor operates as a passive detection cable that triggers an alert when water contacts its conductive elements. The 20-foot length provides substantial coverage for monitoring perimeter areas or specific risk zones within a rack or room layout.
The sensor requires connection to a NetBotz 750 or NetBotz 755 appliance for alarm processing and notification. This integration allows the sensor to become part of a comprehensive environmental monitoring system that can include temperature, humidity, and security sensors.
Relevant factors for this section include Detectable Medium, Color Family, Product Color, Height. When those points are considered together, they give buyers a clearer picture of how the product is equipped, how it fits into deployment, and what kind of day-to-day role it is meant to support.
A strong technical summary explains how the product's interfaces, hardware profile, and operating characteristics work together in real deployment. Buyers often need this context to confirm compatibility with existing devices, expected performance in daily use, and whether installation will be straightforward for IT staff or end users.
Key Product Advantages
The NetBotz Leak Rope Sensor offers proactive protection against one of the most common causes of data center equipment failure. Its early detection capability allows IT teams to respond to leaks before they escalate into major incidents.
Extended Coverage Options
For larger monitoring areas, the sensor footprint can be expanded using the optional NBSE0309 Leak Rope Extension, providing flexibility for diverse room layouts and rack configurations.
- Compatible with extension cables
- Modular deployment approach
Regulatory Compliance
The sensor meets TAA and BAA requirements through Commercial Off-The-Shelf (COTS) compliance, making it suitable for government and institutional procurement where these standards are mandatory.
- TAA|BAA certified
- COTS compliance path
Deployment / Use Cases
The NBES0308 is specifically designed for deployment in technology environments where water intrusion poses a significant risk to electronic equipment. Its primary application is in data centers and network closets where cooling system leaks, plumbing failures, or building envelope issues could threaten server racks, switches, and storage arrays.
Installation typically involves routing the orange detection cable along the floor perimeter, beneath raised flooring, around air conditioning units, or near water pipes and drainage systems. The sensor can be positioned to monitor specific high-risk areas such as underfloor plumbing runs or near overhead piping that services cooling systems.
Data Center Perimeter Monitoring
Deploy along walls and floor edges to detect water entering from building leaks or flooding incidents, providing early warning before water reaches critical equipment.
- Wall perimeter protection
- Floor edge detection
Rack-Level Leak Detection
Install around individual server racks or beneath raised flooring to identify leaks from overhead cooling systems or adjacent equipment before they damage servers and networking gear.
- Rack-specific protection
- Underfloor monitoring
Physical Profile
The sensor unit features a compact enclosure measuring 6.73" wide by 6.34" deep by 2.76" high, with a weight of approximately 15.52 ounces. The bright orange color provides high visibility for installation verification and maintenance inspections. The design supports standard mounting options for secure placement in rack environments or on walls near monitored areas.
The physical profile is practical for deployment planning because the dimensions and weight are clearly defined: 2.76" (70 mm), 6.73" (171 mm), 6.34" (161 mm), 15.52 oz (439.98 g). This helps confirm rack, shelf, desk, or cabinet fit before installation.
- Width
- 6.73" (171 mm)
- Depth
- 6.34" (161 mm)
- Height
- 2.76" (70 mm)
- Weight
- 15.52 oz (439.98 g)
What's in the Box
The package includes everything needed for basic sensor deployment and installation.
Package contents include NetBotz Leak Rope Sensor Cable ties, NetBotz Leak Rope Sensor. These included items support setup, installation, and immediate deployment without needing to source the core bundled accessories separately.
Highlights
- 20-foot orange water detection cable for early leak warning
- Compatible with NetBotz 750 and 755 monitoring appliances
- Expandable coverage with optional NBSE0309 extension cable
- TAA and BAA compliant via COTS for government procurement
- RoHS compliant and environmentally friendly design
- Made in the United States
- Bright orange color for high visibility during installation
- Includes cable ties for secure routing and mounting
- 2-year standard hardware warranty for repair or replacement
- Compact design for flexible deployment in tight spaces
Specifications
| Specifications | |
|---|---|
| Manufacturer | Schneider Electric SA |
| Manufacturer Part Number | NBES0308 |
| Brand Name | APC by Schneider Electric |
| Product Name | NetBotz Leak Rope Sensor |
| Packaged Quantity | 1 Each |
| Product Type | Liquid Leak Sensor |
| Technical Information | |
| Detectable Medium | Water |
| Physical Characteristics | |
| Color Family | Orange |
| Product Color | Orange |
| Height | 2.76" (70 mm) |
| Width | 6.73" (171 mm) |
| Depth | 6.34" (161 mm) |
| Weight (Approximate) | 15.52 oz (439.98 g) |
| Miscellaneous | |
| Package Contents | NetBotz Leak Rope Sensor Cable ties |
| Compatibility | NetBotz Rack Monitor: 450 550 |
| Certifications & Standards | TAA|BAA via COTS |
| Country of Origin | United States |
| TAA Compliant | Yes |
| Environmentally Friendly | Yes |
| Environmental Compliance | Restriction of Hazardous Substances (RoHS) |
| Warranty | |
| Limited Warranty | 2 Year |
User Manual
FAQ
What does the APC NBES0308 NetBotz Leak Rope Sensor detect?
The NBES0308 specifically detects water contact along its 20-foot cable. When water makes contact with the sensor's conductive elements, it triggers an alert through the connected NetBotz monitoring appliance. This makes it ideal for identifying leaks from cooling systems, plumbing, or environmental water intrusion in technology spaces.
What NetBotz appliances is this leak sensor compatible with?
This leak rope sensor requires a compatible NetBotz monitoring appliance for operation. It is designed to work with NetBotz 750 and NetBotz 755 appliances. These units process the sensor signals and provide alert notifications through their management interfaces. The sensor cannot function as a standalone device without one of these compatible appliances.
Can I extend the coverage area beyond the 20-foot cable?
Yes, coverage can be extended using the optional NBSE0309 Leak Rope Extension. This allows you to create longer detection paths for larger rooms or more complex monitoring layouts. The modular approach provides flexibility in deployment while maintaining the same detection reliability and compatibility with NetBotz monitoring systems.
What certifications does this sensor carry for government procurement?
The NBES0308 is TAA (Trade Agreements Act) and BAA (Buy American Act) compliant through the Commercial Off-The-Shelf (COTS) pathway. This certification makes it suitable for purchase by U.S. government agencies and institutions that require TAA/BAA compliance. The sensor is also manufactured in the United States, supporting domestic procurement requirements.
What is included in the package with the leak sensor?
The package contains the NetBotz Leak Rope Sensor itself along with cable ties for installation. The sensor includes the 20-foot orange detection cable with connection terminals, while the cable ties assist with securing the cable along floors, walls, or equipment racks during deployment. No additional mounting hardware or connectors are included beyond these items.
What warranty coverage does APC provide for this leak sensor?
APC provides a 2-year limited hardware warranty for the NBES0308 NetBotz Leak Rope Sensor. This warranty covers repair or replacement of defective units during the warranty period. The warranty supports the product's reliability in critical monitoring applications and provides assurance for long-term deployment in data center and network closet environments.