Product Features
Technical Overview
This switched PDU operates with 208V three-phase power, accepting input voltages from 200V to 240V AC. The 60A input current supports the full 17.3kW power rating, making it suitable for power-intensive server and networking equipment racks.
The outlet configuration includes 21 IEC C13/C15 outlets and 21 IEC C13/C15/C19/C21 outlets, providing flexibility for various equipment power cords. Network management capabilities allow for individual outlet control, power monitoring, and environmental sensing integration.
This section brings together practical product details such as PDU Type, Phase, Plug/Connector Type, Input Voltage, so buyers can judge configuration, deployment fit, and day-to-day suitability with less guesswork.
A strong technical summary explains how the product's interfaces, hardware profile, and operating characteristics work together in real deployment. Buyers often need this context to confirm compatibility with existing devices, expected performance in daily use, and whether installation will be straightforward for IT staff or end users.
Key Product Advantages
This PDU combines high power capacity with intelligent management features for modern data center environments. The switched design provides granular control over power distribution, while the extensive outlet count supports dense equipment configurations.
These strengths make the product easier to deploy and manage in real environments, especially where reliability, usability, and day-to-day operational continuity matter. Notable benefits include Network Management, High-Density Power.
Network Management
Full-featured network management capability enables remote monitoring and control of individual outlets, power measurements, and environmental conditions.
- Interactive LCD display
- Active power measurements (volts, amps, kW, kWh)
- Remote outlet switching
High-Density Power
With 42 outlets and 17.3kW capacity, this PDU supports multiple servers, switches, and storage devices in a single rack installation.
- 42 total outlets
- 17.3kW power rating
- Three-phase 208V power
Deployment / Use Cases
This switched rack PDU is engineered for data center environments requiring reliable power distribution with management capabilities. The three-phase power and high outlet count make it ideal for server racks housing multiple compute nodes, storage arrays, and networking equipment.
Enterprise IT departments can deploy this PDU in colocation facilities, corporate data centers, or server rooms where remote power management and monitoring are essential. The vertical mounting design and 0U rack height allow for efficient use of rack space alongside equipment.
This section brings together practical product details such as PDU Type, Phase, Plug/Connector Type, Input Voltage, so buyers can judge configuration, deployment fit, and day-to-day suitability with less guesswork.
Data Center Server Racks
Power multiple servers, switches, and storage devices in high-density rack configurations with managed power distribution.
Network Equipment Cabinets
Provide reliable power to networking gear with the ability to remotely reboot individual devices when needed.
Physical Profile
The PDU features a vertical mounting design with a 0U rack height, allowing installation along the side of standard 19-inch racks without consuming rack unit space. The black finish matches typical data center equipment, while the compact 2.20" width and 2.95" depth ensure minimal intrusion into the rack workspace.
- Width
- 2.20" (56 mm)
- Depth
- 2.95" (75 mm)
- Height
- 0U
- Weight
- 24.47 lb (11099.41 g)
- Length
- 5.9 ft (1.80 m)
Highlights
- 17.3kW power capacity for high-density rack deployments
- 42 total outlets with mixed IEC C13/C15 and C13/C15/C19/C21 configurations
- Three-phase 208V power with 60A input current
- Switched PDU architecture for remote outlet control
- Network management with interactive LCD display
- Active power measurements including volts, amps, kW, and kWh
- Vertical mounting with 0U rack height design
- IEC 60309 60A 3P+PE input connector
- 3-year APC warranty for reliable operation
- TAA compliant and environmentally friendly construction
Specifications
| Specifications | |
|---|---|
| Manufacturer | Schneider Electric SA |
| Manufacturer Part Number | APDU10452SW |
| Brand Name | APC by Schneider Electric |
| Product Line | NetShelter |
| Product Name | NetShelter 42-Outlets PDU |
| Product Type | PDU |
| Technical Information | |
| PDU Type | Switched |
| Phase | Three Phase |
| Plug/Connector Type | IEC 60309 60A 3P+PE |
| Receptacle Type | IEC 60320 C13/C15/C19/C21,IEC 60320 C13/C15 |
| Receptacle Detail | 21 x IEC 60320 C13/C15,21 x IEC 60320 C13/C15/C19/C21 |
| Power Description | |
| Input Voltage | 208 V |
| Input Voltage Range | 200 V AC - 240 V AC |
| Output Voltage | 208 V AC |
| Power Rating (VA) | 17.30 kVA |
| Power Rating (Watt) | 17.30 kW |
| Input Current | 60 A |
| Physical Characteristics | |
| Color Family | Black |
| Product Color | Black |
| Mounting Orientation | Vertical |
| Form Factor | Rack |
| Placement | Side |
| Rack Height | 0U |
| Cord Length | 5.9 ft (1.80 m) |
| Height | 71.89" (1826 mm) |
| Width | 2.20" (56 mm) |
| Depth | 2.95" (75 mm) |
| Weight (Approximate) | 24.47 lb (11099.41 g) |
| Miscellaneous | |
| Country of Origin | United States |
| TAA Compliant | Yes |
| Environmentally Friendly | Yes |
| Environmental Compliance | Waste Electrical and Electronic Equipment Directive (WEEE),Restriction of Hazardous Substances (RoHS),China Restriction of Hazardous Substances (China RoHS),Registration, Evaluation, Authorization and Restriction of Chemicals (REACH) |
| Warranty | |
| Limited Warranty | 3 Year |
User Manual
FAQ
What is the power capacity of this APC NetShelter PDU?
This PDU delivers 17.3kW (17.30 kVA) of power capacity, supporting high-density server and networking equipment in rack environments. The three-phase 208V configuration with 60A input current provides robust power distribution for demanding data center applications.
How many outlets does this rack PDU provide and what types are they?
The PDU features 42 total outlets: 21 IEC C13/C15 outlets and 21 IEC C13/C15/C19/C21 outlets. This mixed configuration accommodates both standard equipment power cords and higher-power devices requiring C19 or C21 connections, providing flexibility for diverse rack deployments.
What input connector type does this PDU use?
This PDU uses an IEC 60309 60A 3P+PE input connector for three-phase power delivery. The connector ensures secure attachment to three-phase power sources commonly found in data center environments, supporting the 208V input voltage requirement.
Is this a switched or basic PDU?
This is a switched PDU, meaning it provides network management capabilities for remote monitoring and control. Features include individual outlet switching, active power measurements, and an interactive LCD display for local management and status viewing.
How is this PDU mounted in a rack?
The PDU is designed for vertical mounting along the side of standard 19-inch racks with a 0U rack height. This mounting orientation conserves rack unit space for equipment while providing accessible power distribution. The unit includes mounting hardware for secure installation.
What warranty coverage does this APC PDU include?
This PDU includes a 3-year limited warranty from APC by Schneider Electric. The warranty covers defects in materials and workmanship, providing assurance of reliable performance in data center and enterprise environments.
What power capacity is listed for this UPS?
The listed power specification is 17.30 kVA, which helps position the unit for the right load level and installation role.
What voltage details are listed?
The listed power specification is 208 V, which helps position the unit for the right load level and installation role.