APC by Schneider Electric APDU9966 NetShelter 9000 Switched Rack PDU - 17. 3kW - 208V - 32 Outlets - 12x C19/C21 - 20x C13/C15 - ZeroU - SNMP Redfish
Manufacturer: APC by Schneider Electric
FleetNetwork servicesServices FleetNetwork
Business volume discounts
Technical guidance
Preparation & staging
QC · ON · AB · BC
Order with confidenceCommander en confiance
TLS encrypts payment data in transit.Les données de paiement sont chiffrées en transit par TLS.
Tracked delivery across Canada.Livraison avec suivi au Canada. Returns policyPolitique de retour
A Canadian business since 2007.Une entreprise québécoise depuis 2007. 1-844-836-8268
Product Features
FLEETNETWORK POWER EXPERTS
A power solution built around your project.
Warehouses, server rooms, multi-site networks and healthcare facilities: get personalized advice and a quote. When needed, we involve the manufacturer to validate the configuration with you.
Critical medical and life-safety applications require dedicated validation and approved equipment.
Loading your contact form...
Technical Overview
The PDU operates on a three-phase 208V AC input and delivers the same 208V output, ensuring consistent voltage for connected equipment. It accepts power via an IEC 60309 60A 3P+PE connector and distributes it through a total of 32 outlets: 12 high-power IEC C19/C21 outlets and 20 standard IEC C13/C15 outlets. This mix accommodates a wide range of server and network device power cords.
Network management is facilitated through an integrated RJ-45 port, supporting industry-standard SNMP and Redfish interfaces for integration into existing data center infrastructure management (DCIM) systems. The unit's physical design is optimized for side-mount installation in racks, with a compact profile that does not consume rack unit (U) space.
This section brings together practical product details such as PDU Type, Phase, Plug/Connector Type, Input Voltage, so buyers can judge configuration, deployment fit, and day-to-day suitability with less guesswork.
Key Product Advantages
This PDU combines high power capacity with intelligent management in a space-saving form factor, addressing critical needs in modern data centers.
High-Density Power Distribution
With 17.3 kW capacity and 32 outlets, the unit efficiently powers multiple high-demand devices from a single power source, reducing cable clutter and simplifying power infrastructure.
- 17.3 kW/17.3 kVA power rating
- 32 total outlets (12 C19/C21, 20 C13/C15)
- 208V three-phase input and output
Intelligent Remote Management
SNMP and Redfish support allows for remote monitoring of power consumption, outlet-level control, and integration with data center management software for proactive power management.
- Outlet-level switching and monitoring
- SNMP and Redfish protocol support
- Network management via RJ-45
Rack Space Optimization
The ZeroU side-mount design installs vertically without consuming rack units, maximizing space for servers, switches, and other IT equipment within the rack enclosure.
- ZeroU mounting preserves rack space
- Side placement for easy cable access
- Compact dimensions: 4.37"W x 2.99"D
Deployment / Use Cases
The APC NetShelter 9000 Switched PDU is designed for environments where reliable, manageable, and high-capacity power distribution is essential. Its robust power handling and remote management features make it ideal for centralized power control in server racks and data center cabinets.
Typical deployments include enterprise data centers, colocation facilities, and high-density server rooms where multiple high-power devices like blade servers, storage systems, and network switches require dedicated, monitored power sources. The side-mount ZeroU installation is particularly beneficial in fully populated racks where every rack unit is allocated to revenue-generating equipment.
Data Center Server Racks
Provide centralized, switched power to multiple servers and storage units within a single rack, with remote management for load balancing and outage prevention.
Network Equipment Cabinets
Power high-density switches, routers, and other networking gear while enabling remote reboot capabilities for individual devices via outlet-level control.
Physical Profile
The PDU features a slim, vertical design with dimensions of 72.17" height, 4.37" width, and 2.99" depth, allowing it to mount neatly along the side of a standard rack. Its side placement facilitates straightforward cable routing and management. The unit includes a 6-foot (1.82 m) input power cord and has an approximate weight of 30.86 lb (13,997.86 g). The construction complies with RoHS environmental standards.
- Width
- 4.37" (111 mm)
- Depth
- 2.99" (76 mm)
- Height
- 72.17" (1833 mm)
- Weight
- 30.86 lb (13997.86 g)
- Length
- 6 ft (1.82 m)
What's in the Box
The package includes all necessary components for installation and operation.
Highlights
- 17.3 kW (17.3 kVA) power capacity for high-density applications
- 32 total outlets: 12 IEC C19/C21 and 20 IEC C13/C15
- ZeroU side-mount design saves rack space
- Remote management via SNMP and Redfish protocols
- Three-phase 208V input and output voltage
- IEC 60309 60A 3P+PE input connector
- Outlet-level switching and monitoring capabilities
- Includes rack mounting brackets and serial configuration cable
- 3-year limited warranty
- RoHS compliant and environmentally friendly
Specifications
| Specifications | |
|---|---|
| Manufacturer | Schneider Electric SA |
| Manufacturer Part Number | APDU9966 |
| Brand Name | APC by Schneider Electric |
| Product Series | 9000 |
| Product Name | NetShelter 9000 32-Outlet PDU |
| Product Type | PDU |
| Technical Information | |
| PDU Type | Switched |
| Phase | Three Phase |
| Plug/Connector Type | IEC 60309 60A 3P+PE |
| Receptacle Type | IEC 60320 C19/C21,IEC 60320 C13/C15 |
| Receptacle Detail | 12 x IEC 60320 C19/C21,20 x IEC 60320 C13/C15 |
| Power Description | |
| Input Voltage | 208 V |
| Output Voltage | 208 V AC |
| Power Rating (VA) | 17.30 kVA |
| Power Rating (Watt) | 17.30 kW |
| Input Current | 60 A |
| Management | |
| Management | SNMP Redfish |
| Interfaces/Ports | |
| Network (RJ-45) | Yes |
| Physical Characteristics | |
| Mount Type | Rack-mountable |
| Placement | Side |
| Cord Length | 6 ft (1.82 m) |
| Height | 72.17" (1833 mm) |
| Width | 4.37" (111 mm) |
| Depth | 2.99" (76 mm) |
| Weight (Approximate) | 30.86 lb (13997.86 g) |
| Miscellaneous | |
| Package Contents | NetShelter 9000 32-Outlet PDU Installation guide Rack mounting brackets Safety guide Serial configuration cable |
| Country of Origin | India |
| Environmentally Friendly | Yes |
| Environmental Compliance | Restriction of Hazardous Substances (RoHS) |
| Warranty | |
| Limited Warranty | 3 Year |
User Manual
FAQ
What is the power capacity of this APC NetShelter PDU?
This PDU has a power rating of 17.3 kW (17.3 kVA) at 208V three-phase. It can handle high-power loads typical in data center environments, supporting multiple servers, storage systems, and networking equipment simultaneously from a single power source.
How many outlets does this PDU have and what types are they?
The unit provides 32 outlets total: 12 high-power IEC C19/C21 outlets and 20 standard IEC C13/C15 outlets. This mix accommodates a wide range of server and network device power cords, allowing flexible configuration for different equipment types within a rack.
What does 'ZeroU mounting' mean for this PDU?
ZeroU mounting means the PDU installs vertically along the side of a standard 19-inch rack without consuming any rack units (U) of vertical space. This design preserves all rack space for IT equipment like servers and switches, while the PDU's slim profile (4.37" wide) fits neatly alongside the rack frame.
How can I remotely manage this switched PDU?
The PDU includes an RJ-45 network port and supports SNMP and Redfish management protocols. This allows remote monitoring of power consumption, outlet-level control (on/off/reboot), and integration with data center infrastructure management (DCIM) software for centralized power management across multiple racks.
What input power connector does this PDU use?
It uses an IEC 60309 60A 3P+PE connector for three-phase 208V input power. This industrial-grade connector is common in data center power distribution systems and requires a compatible power source or upstream PDU for proper installation.
What is included in the box with this PDU?
The package contains the NetShelter 9000 32-Outlet PDU unit, an installation guide, rack mounting brackets for side installation, a safety guide, and a serial configuration cable for initial setup. All necessary hardware for mounting and basic configuration is provided.
What power capacity is listed for this UPS?
The listed power specification is 17.30 kVA, which helps position the unit for the right load level and installation role.
What voltage details are listed?
The listed power specification is 208 V, which helps position the unit for the right load level and installation role.