APC by Schneider Electric SYH4K6RMT-P1 APC Symmetra RM 4kVA UPS - Double Conversion Online - SNMP Manageable - 12. 2 Min Full Load - Rack-Mountable 10U
Business volume discounts
Technical guidance
Preparation & staging
QC · ON · AB · BC
Product Features
Technical Overview
This double conversion online UPS continuously converts incoming AC power to DC and back to AC, providing complete isolation from utility power issues. The 4 kVA capacity supports substantial loads, while the 208V AC input is optimized for commercial and data center environments. Output delivers both 120V and 208V AC at 60 Hz with pure sine wave quality, compatible with sensitive servers, networking gear, and storage systems.
The battery subsystem uses maintenance-free lead-acid chemistry with spill-proof design, typically recharging within 4 hours after use. Thermal management handles up to 1686 BTU/h dissipation, with operation supported in environments up to 104°F (40°C). Dataline protection via RJ-45 connectors safeguards connected network equipment from power surges.
This section brings together practical product details such as Plug/Connector Type, Receptacle Type, Receptacle Detail, Load Capacity (VA), so buyers can judge configuration, deployment fit, and day-to-day suitability with less guesswork.
Key Product Advantages
The Symmetra RM 4kVA combines enterprise-grade power protection with rack-optimized form factor, making it ideal for organizations needing reliable backup power in space-constrained environments. The mixed outlet configuration provides flexibility for connecting both standard and high-power equipment, while the comprehensive alarm and status indicators offer clear visibility into system health.
Double Conversion Technology
Provides complete power conditioning by continuously regenerating clean AC power, eliminating transfer time and protecting against all common power problems including blackouts, brownouts, surges, and frequency variations.
SNMP Management Capability
Enables remote monitoring, configuration, and shutdown commands through standard network management protocols, allowing IT staff to manage power infrastructure alongside other network devices.
Rack-Optimized Design
Engineered specifically for rack deployment with 10U height, standard 19" width, and included mounting brackets and support rails for secure installation in standard server racks.
Deployment / Use Cases
This UPS is particularly suited for environments requiring clean, reliable power for sensitive electronic equipment. The 208V input makes it compatible with standard commercial power distribution, while the 120V/208V output flexibility accommodates both North American standard equipment and higher-voltage devices.
Ideal for small to medium server rooms, the 4 kVA capacity can support multiple rack-mounted devices with sufficient runtime for either continued operation during brief outages or controlled shutdown procedures during extended power failures. The SNMP management capability integrates with existing network monitoring systems, providing alerts and enabling remote power management.
Data Center Rack Deployment
Protect rack-mounted servers, switches, and storage arrays in data center environments where space efficiency and high-density power protection are critical requirements.
Network Closet Power Backup
Ensure continuous operation of networking equipment, VoIP systems, and security appliances in distributed network closets and telecommunications rooms.
Physical Profile
The black rack-mountable enclosure occupies 10U of vertical rack space with dimensions of 17.52" height × 19.02" width × 28.74" depth (445 × 483 × 730 mm). Weighing approximately 324.67 pounds, this substantial unit requires proper rack reinforcement and consideration of floor loading in deployment planning. The included rack mounting brackets and support rails facilitate secure installation in standard 19" server racks.
- Width
- 19.02" (483 mm)
- Depth
- 28.74" (730 mm)
- Height
- 10U
- Weight
- 324.67 lb (147267.83 g)
- Length
- 10 ft (3048 mm)
What's in the Box
The package includes the Symmetra RM 4kVA UPS unit along with all necessary installation and documentation components for immediate deployment.
Highlights
- 4 kVA double conversion online UPS with pure sine wave output
- 12.2 minutes runtime at full load, 28.7 minutes at half load
- SNMP manageable for remote monitoring and control
- 14 total outlets: 12 × NEMA 5-20R and 2 × NEMA L6-20R
- 208V AC input with 120V/208V AC output flexibility
- Rack-mountable 10U design with included mounting hardware
- Maintenance-free lead-acid battery with spill-proof design
- Dataline protection via RJ-45 connectors
- Comprehensive alarms for low battery and on-battery status
- 2-year limited warranty with optional extended coverage
Specifications
| Specifications | |
|---|---|
| Manufacturer | Schneider Electric SA |
| Manufacturer Part Number | SYH4K6RMT-P1 |
| Brand Name | APC by Schneider Electric |
| Product Line | Symmetra |
| Product Series | RM |
| Product Name | Symmetra RM 4kVA UPS |
| Product Type | Double Conversion Online UPS |
| Technical Information | |
| Plug/Connector Type | NEMA L6-30P (30A Twist-Lock),Hard Wire 3-wire |
| Receptacle Type | NEMA L6-30P 30A |
| Receptacle Detail | 12 x NEMA 5-20R,2 x NEMA L6-20R |
| Number of Battery & Surge Outlets | 14 |
| Dataline Protection | RJ-45 |
| Cord Length | 10 ft (3048 mm) |
| Power Description | |
| Load Capacity (VA) | 4 kVA |
| Input Voltage | 208 V AC |
| Output Voltage | 120 V AC,208 V AC |
| Output Frequency | 60 Hz |
| Waveform Type | Sine Wave |
| Management | |
| Network Management | SNMP Manageable |
| Alarm | Low Battery,On Battery |
| Controls/Indicators | |
| Status Indicators | Overload Replace Battery |
| Battery Information | |
| Battery Characteristics | Spill-proof/Maintenance-free |
| Battery Chemistry | Lead Acid |
| Backup/Run Time (Full Load) | 12.20 Minute |
| Backup/Run Time (Half Load) | 28.70 Minute |
| Typical Battery Recharge Time | 4 Hour |
| Environmental Conditions | |
| Maximum Operating Temperature | 104°F (40°C) |
| Thermal Dissipation | 1686 BTU/h |
| Physical Characteristics | |
| Product Color | Black |
| Form Factor | Rack-mountable |
| Rack Height | 10U |
| Height | 17.52" (445 mm) |
| Width | 19.02" (483 mm) |
| Depth | 28.74" (730 mm) |
| Weight (Approximate) | 324.67 lb (147267.83 g) |
| Miscellaneous | |
| Package Contents | Symmetra RM 4kVA UPS CD with software Rack mounting brackets Rack mounting support rails User manual |
| Environmentally Friendly | Yes |
| Warranty | |
| Limited Warranty | 2 Year |
| Additional Warranty Information | 2 years repair or replace, optional on-site warranties available, optional extended warranties available |
User Manual
FAQ
What is the power capacity of this APC Symmetra RM UPS?
This UPS provides 4 kVA (kilovolt-ampere) of power capacity, which represents the maximum load it can support. This capacity is suitable for protecting multiple servers, networking equipment, or storage devices in a rack-mounted configuration, with the actual supported wattage depending on the power factor of connected equipment.
How long will this UPS run at full load during a power outage?
At full load (4 kVA), the UPS provides 12.2 minutes of runtime from its internal batteries. This duration allows sufficient time for either continued operation during brief outages or for initiating and completing graceful shutdown procedures for protected equipment to prevent data loss or hardware damage.
What types of outlets does this UPS have and how many?
The unit includes 14 total outlets with mixed configurations: 12 NEMA 5-20R outlets (standard 120V, 20A) and 2 NEMA L6-20R outlets (208V, 20A twist-lock). This combination provides flexibility for connecting both standard office equipment and higher-power devices that require 208V power in data center or commercial environments.
Can this UPS be managed remotely?
Yes, this UPS features SNMP (Simple Network Management Protocol) manageability, allowing integration with network management systems for remote monitoring, configuration, and control. This enables IT staff to receive alerts, check status, and initiate shutdown commands from anywhere on the network, facilitating proactive power management.
What rack space does this UPS require for installation?
The UPS occupies 10U (unit) of vertical space in a standard 19" server rack, with dimensions of 17.52" height × 19.02" width × 28.74" depth. It includes rack mounting brackets and support rails for secure installation. The substantial weight of 324.67 pounds requires proper rack reinforcement and consideration of floor loading capacity.
What input voltage does this UPS require?
This UPS requires 208V AC input power, which is standard in commercial and data center power distribution systems in North America. The input connects via a NEMA L6-30P plug or can be hardwired for permanent installation, providing compatibility with typical three-phase power distribution found in enterprise environments.
What power capacity is listed for this UPS?
The listed power specification is 4 kVA, which helps position the unit for the right load level and installation role.
How many outlets are available?
The product includes 14, which helps buyers understand how many connected devices it can support in its intended deployment.