CyberPower CPS-1215RM Basic Rack PDU - Single Phase 1.80 kVA - 15A - 10 Outlets - 1U Horizontal - 15 ft Cord - 3-Year Warranty
Business volume discounts
Technical guidance
Preparation & staging
QC · ON · AB · BC
Product Features
Technical Overview
The CPS-1215RM operates on single-phase power with an input voltage range of 100-125 V AC and nominal input voltage of 120 V AC. The 15A input current supports the 1.80 kVA power rating, providing sufficient capacity for multiple rack-mounted servers, networking equipment, or storage devices.
Output voltage remains stable between 100-120 V AC, ensuring compatible power delivery to connected equipment. The unit incorporates both overload protection and short circuit protection mechanisms to safeguard connected devices from power anomalies that could cause damage or downtime.
Relevant factors for this section include PDU Type, Phase, Plug/Connector Type, Input Voltage. When those points are considered together, they give buyers a clearer picture of how the product is equipped, how it fits into deployment, and what kind of day-to-day role it is meant to support.
A strong technical summary explains how the product's interfaces, hardware profile, and operating characteristics work together in real deployment. Buyers often need this context to confirm compatibility with existing devices, expected performance in daily use, and whether installation will be straightforward for IT staff or end users.
Key Product Advantages
The CPS-1215RM combines essential power distribution features with rack-optimized design for efficient data center deployment. Its straightforward approach to power management eliminates complexity while maintaining reliability for critical IT infrastructure.
Rack-Optimized Design
The 1U horizontal form factor maximizes rack space utilization while providing 10 outlets for equipment connectivity. The 15 ft power cord offers installation flexibility within standard rack configurations.
- 1U rack height
- Horizontal mounting
- 17.25" width fits standard racks
Essential Power Protection
Built-in overload and short circuit protection mechanisms prevent damage to connected equipment from power anomalies. The cord retention trays maintain secure connections to avoid accidental disconnections.
- Overload protection
- Short circuit protection
- Cord retention system
Reliable Power Delivery
With 1.80 kVA capacity and stable 100-120 V AC output, the PDU ensures consistent power to all connected devices. The single-phase design simplifies installation and compatibility with standard power sources.
- 1.80 kVA capacity
- Stable voltage output
- Single-phase operation
Deployment / Use Cases
The CPS-1215RM Basic Rack PDU serves as a foundational power distribution solution for various IT environments requiring reliable, straightforward power management. Its design prioritizes compatibility with standard rack infrastructure and common North American power requirements.
In data center deployments, this PDU efficiently distributes power to multiple rack-mounted servers, network switches, and storage arrays. The 10-outlet configuration supports typical equipment densities in 1U to 4U rack spaces, while the 15 ft cord accommodates various rack placement scenarios relative to power sources.
Server Rack Power Distribution
Ideal for distributing power to multiple servers within a single rack enclosure. The 10 outlets support typical server configurations with room for networking equipment.
- Server power distribution
- Network equipment support
- Rack-optimized layout
Network Closet Infrastructure
Suitable for network closets and telecommunications rooms where space is limited but reliable power distribution is essential. The compact 1U design maximizes usable space.
- Space-efficient design
- Network equipment compatibility
- Standard rack mounting
Physical Profile
The CPS-1215RM features a black finish with dimensions optimized for standard 19-inch rack mounting. Measuring 17.25" wide, 1.75" high, and 4.75" deep, the unit occupies minimal rack space while providing full functionality. The 5 lb weight ensures easy installation and stable mounting in rack environments.
The physical profile is practical for deployment planning because the dimensions and weight are clearly defined: 1U, 17.25" (438.15 mm), 4.75" (120.65 mm), 5 lb (2267.96 g). This helps confirm rack, shelf, desk, or cabinet fit before installation.
- Width
- 17.25" (438.15 mm)
- Depth
- 4.75" (120.65 mm)
- Height
- 1U
- Weight
- 5 lb (2267.96 g)
- Length
- 15 ft (4.57 m)
What's in the Box
The CPS-1215RM Basic Rack PDU ships complete with all necessary components for immediate deployment in rack environments.
Highlights
- 1.80 kVA power capacity for reliable equipment support
- 10 NEMA 5-15R outlets for multiple device connections
- 15A input current with 100-125 V AC input range
- 1U horizontal rack-mountable design saves space
- 15 ft power cord provides installation flexibility
- Overload and short circuit protection safeguards equipment
- Cord retention trays prevent accidental disconnections
- UL Listed for safety compliance
- 3-year manufacturer warranty with technical support
- Black finish complements standard rack aesthetics
Specifications
| Specifications | |
|---|---|
| Manufacturer | CyberPower Systems, Inc |
| Manufacturer Part Number | CPS-1215RM |
| Brand Name | CyberPower |
| Product Model | CPS-1215RM |
| Product Name | CPS1215RM Single Phase 100 - 120 VAC 15A Basic |
| Product Condition | New |
| Product Type | PDU |
| Technical Information | |
| PDU Type | Basic |
| Phase | Single Phase |
| Plug/Connector Type | NEMA 5-15P |
| Receptacle Type | NEMA 5-15R |
| Receptacle Detail | 10 x NEMA 5-15R |
| Protection Type | Overload Protection,Short Circuit Protection |
| Locking Receptacles | Cord Retention Tray |
| Power Description | |
| Input Voltage | 120 V AC |
| Input Voltage Range | 100 V AC - 125 V AC |
| Output Voltage Range | 100 V AC - 120 V AC |
| Power Rating (VA) | 1.80 kVA |
| Input Current | 15 A |
| Physical Characteristics | |
| Color Family | Black |
| Product Color | Black |
| Mounting Orientation | Horizontal |
| Mount Type | Rack-mountable,Rail-mountable |
| Form Factor | Rack |
| Rack Height | 1U |
| Cord Length | 15 ft (4.57 m) |
| Height | 1.75" (44.45 mm) |
| Width | 17.25" (438.15 mm) |
| Depth | 4.75" (120.65 mm) |
| Weight (Approximate) | 5 lb (2267.96 g) |
| Environmental Conditions | |
| Minimum Operating Temperature | 32°F (0°C) |
| Maximum Operating Temperature | 104°F (40°C) |
| Minimum Storage Temperature | 5°F (-15°C) |
| Maximum Storage Temperature | 113°F (45°C) |
| Miscellaneous | |
| Package Contents | CPS1215RM Warranty Card/Manual |
| Application/Usage | Data Center |
| Country of Origin | China |
| UL Listed | Yes |
| Warranty | |
| Limited Warranty | 3 Year |
| Additional Warranty Information | CyberPower stands behind its products with an industry-leading 3 year warranty. CyberPower also offers a #1 rated technical support team that will assist you with product, installation, or warranty concerns --- Free of Charge. |
User Manual
FAQ
What is the power capacity of the CPS-1215RM PDU?
The CyberPower CPS-1215RM delivers 1.80 kVA (kilovolt-ampere) power capacity with a 15A input current. This capacity supports multiple rack-mounted devices simultaneously, making it suitable for standard server rack configurations. The single-phase design operates within a 100-125 V AC input range with stable 100-120 V AC output to connected equipment.
How many outlets does this rack PDU provide?
This PDU features 10 NEMA 5-15R outlets, which accommodate standard North American plugs. All outlets receive power from the single-phase input and are protected by overload and short circuit mechanisms. The outlet configuration supports typical densities of rack-mounted servers, network switches, and other IT equipment in data center environments.
What rack mounting options are available?
The CPS-1215RM is designed for horizontal 1U rack mounting in standard 19-inch racks. The unit measures 17.25 inches wide to fit standard rack widths, with a height of 1.75 inches (1U) and depth of 4.75 inches. It supports both rack-mountable and rail-mountable installation methods for flexible deployment in various rack configurations.
What protection features does this PDU include?
This basic rack PDU incorporates overload protection and short circuit protection to safeguard connected equipment. The overload protection prevents damage from excessive current draw, while short circuit protection responds to fault conditions. Additionally, cord retention trays help maintain secure connections to prevent accidental disconnections that could interrupt power to critical devices.
What is the length of the power cord?
The CPS-1215RM includes a 15 ft (4.57 m) power cord with a NEMA 5-15P plug. This length provides flexibility in rack placement relative to power sources in data center environments. The cord is permanently attached to the PDU and designed to handle the full 15A current capacity of the unit without voltage drop issues.
What warranty coverage is provided?
CyberPower provides a 3-year limited warranty for the CPS-1215RM Basic Rack PDU. The warranty covers manufacturing defects and includes access to CyberPower's technical support team for product, installation, or warranty concerns at no additional charge. The unit is also UL Listed, indicating compliance with safety standards for electrical equipment.