Description

Product Overview

The CyberPower MBP30A5 is a 30A maintenance bypass panel designed for reliable power distribution and UPS system maintenance in rack-mounted environments. This hot-swappable PDU provides a seamless transition between normal and bypass modes, ensuring continuous power availability during UPS servicing or failure scenarios.

Engineered for single-phase 120V AC systems, the panel features five NEMA 5-20R outlets to support multiple connected devices. Its compact 1U rack-mount design optimizes space in standard server cabinets, while the included 6-foot utility cord and 3.3-foot UPS cord facilitate flexible installation. The black finish and RoHS compliance align with modern data center aesthetics and environmental standards.

This section brings together practical product details such as PDU Type, Phase, Plug/Connector Type, Input Voltage, so buyers can judge configuration, deployment fit, and day-to-day suitability with less guesswork.

Dimensions
Width
17" (431.80 mm)
Depth
3" (76.20 mm)
Height
1U
Weight
5.90 lb (2676.19 g)
Power Specifications
Input Current30 A
Input Voltage120 V AC
Output Voltage120 V AC
Connectors and Outlets
Input Plugs2 x NEMA L5-30R
Receptacles5 x NEMA 5-20R
Cord Length6 ft (1.83 m)
Physical Profile
Mount TypeRack-mountable
Rack Height1U
Weight5.90 lb (2676.19 g)

Technical Overview

This maintenance bypass panel operates with a 30A input current derated to 24A, handling an input voltage range of 100-120V AC. The hot-swappable architecture allows for safe removal and replacement of connected UPS units without interrupting power to downstream equipment. Two NEMA L5-30R input plugs accommodate both utility and UPS output connections, providing redundancy and operational flexibility.

LED indicators display Normal (green) and Bypass (red) modes, offering clear visual status at a glance. The panel's electrical design maintains stable 120V AC output across all five NEMA 5-20R receptacles, supporting standard North American power devices. Phase synchronization and voltage regulation ensure compatibility with sensitive IT hardware during mode transitions.

This section brings together practical product details such as PDU Type, Phase, Plug/Connector Type, Input Voltage, so buyers can judge configuration, deployment fit, and day-to-day suitability with less guesswork.

Input Voltage Range100-120V AC
Outlet Count5
Rack Space1U
Hot-swappableSingle PhaseNEMA Compliant

Key Product Advantages

The MBP30A5 delivers critical maintenance capabilities for UPS-protected environments, combining robust power handling with intuitive operation. Its design prioritizes safety and continuity, enabling technicians to service or replace UPS systems without powering down connected equipment.

These strengths make the product easier to deploy and manage in real environments, especially where reliability, usability, and day-to-day operational continuity matter. Notable benefits include Zero-Downtime Maintenance, Rack-Optimized Form Factor.

Zero-Downtime Maintenance

Switch between normal and bypass modes seamlessly, maintaining power to connected devices during UPS servicing or failure events.

  • Hot-swappable design
  • LED mode indicators
  • Manual bypass switching

Rack-Optimized Form Factor

Occupies only 1U of rack space with dimensions of 17"W x 2"H x 3"D, fitting standard 19-inch server cabinets efficiently.

  • Includes mounting brackets
  • Black finish for professional appearance
  • Lightweight at 5.9 lbs

Deployment / Use Cases

This maintenance bypass panel is engineered for data centers, server rooms, and network closets where UPS systems require periodic maintenance or emergency replacement. It serves as a critical component in power continuity plans, allowing IT staff to perform UPS servicing during business hours without disrupting operations.

Typical deployments include supporting rack-mounted servers, network switches, storage arrays, and telecommunications equipment. The panel is particularly valuable in environments with redundant power architectures, where it can be integrated into A/B power feeds to maintain uptime during UPS maintenance windows. Its NEMA 5-20R outlets accommodate standard IT power cords, making it compatible with most North American data center equipment.

Data Center Maintenance

Enable scheduled UPS servicing without powering down critical servers and network infrastructure, maintaining business continuity.

Emergency UPS Replacement

Provide immediate bypass capability during UPS failure events, keeping systems operational while replacements are installed.

Physical Profile

The panel features a compact black chassis measuring 17 inches wide, 2 inches high, and 3 inches deep, occupying exactly 1U of vertical rack space. This slim profile maximizes cabinet density while providing full front-panel access to all outlets and indicators. The included rack-mount brackets and mounting hardware support secure installation in standard 19-inch racks, with weight distribution optimized for stable mounting. The black powder-coat finish resists scratches and maintains a professional appearance in data center environments.

Color
Black
Dimensions
Width
17" (431.80 mm)
Depth
3" (76.20 mm)
Height
1U
Weight
5.90 lb (2676.19 g)
Length
6 ft (1.83 m)

What's in the Box

The package includes all necessary components for immediate deployment and installation.

Maintenance Bypass MBP30A5 6-ft. utility cord 3.3-ft. UPS cord
2 x Rackmount Brackets
4 x Flat Head Screws M4X8L
4 x Pan Head Screws M5X12L User Manual Registration Card
Maintenance Bypass MBP30A5
[custom-highlights]

Highlights

  • 30A maintenance bypass panel with hot-swappable design
  • Five NEMA 5-20R outlets for multiple device connections
  • 1U rack-mount form factor for space-efficient installation
  • 120V AC input with 100-120V AC operating range
  • Includes 6-foot utility cord and 3.3-foot UPS cord
  • LED indicators for Normal (green) and Bypass (red) modes
  • Black finish with RoHS environmental compliance
  • Three-year limited warranty for long-term reliability
[/custom-highlights][custom-specifications]

Specifications

Specifications
ManufacturerCyberPower Systems, Inc
Manufacturer Part NumberMBP30A5
Brand NameCyberPower
Product SeriesMaintenance Bypass
Product ModelMBP30A5
Product NameMBP30A5 120 VAC 30A Maintenance Bypass
Product TypePDU
Technical Information
PDU TypeHot-swappable
PhaseSingle Phase
Plug/Connector TypeNEMA L5-30R
Plug/Connector Detail2 x NEMA L5-30R
Receptacle TypeNEMA 5-20R
Receptacle Detail5 x NEMA 5-20R
Power Description
Input Voltage120 V AC
Input Voltage Range100 V AC - 120 V AC
Output Voltage120 V AC
Input Current30 A
Physical Characteristics
Color FamilyBlack
Product ColorBlack
Mount TypeRack-mountable
Rack Height1U
Cord Length6 ft (1.83 m)
Height2" (50.80 mm)
Width17" (431.80 mm)
Depth3" (76.20 mm)
Weight (Approximate)5.90 lb (2676.19 g)
Miscellaneous
Package ContentsMaintenance Bypass MBP30A5 6-ft. utility cord 3.3-ft. UPS cord 2 x Rackmount Brackets 4 x Flat Head Screws M4X8L 4 x Pan Head Screws M5X12L User Manual Registration Card
Energy StarNo
Country of OriginChina
Environmentally FriendlyYes
Environmental ComplianceRestriction of Hazardous Substances (RoHS)
Warranty
Limited Warranty3 Year
[/custom-specifications][custom-user-manual]

User Manual

This section contains official documentation provided by the manufacturer, including product manuals, brochures, and supplementary materials.
[/custom-user-manual][custom-faq]

FAQ

What is the purpose of a maintenance bypass panel?

A maintenance bypass panel allows technicians to service or replace a UPS system without interrupting power to connected equipment. It provides a manual switching mechanism that bypasses the UPS, routing utility power directly to downstream devices during maintenance windows or UPS failure events.

What input connectors does the MBP30A5 use?

The panel features two NEMA L5-30R input plugs. One connects to utility power, while the other connects to the UPS output. This dual-input design enables seamless switching between normal UPS-protected power and direct utility bypass modes.

How many devices can I connect to this panel?

The MBP30A5 provides five NEMA 5-20R outlets, supporting up to five standard North American power devices simultaneously. Each outlet delivers 120V AC power, compatible with servers, switches, and other rack-mounted IT equipment.

What rack space does this panel require?

This panel occupies 1U of vertical rack space with dimensions of 17 inches wide, 2 inches high, and 3 inches deep. It includes mounting brackets and hardware for installation in standard 19-inch server racks, making it ideal for space-constrained data center environments.

What safety features are included?

The panel includes LED indicators that clearly show Normal (green) and Bypass (red) operational modes. Its hot-swappable design allows safe disconnection of UPS units, while the derated 24A operation provides headroom for stable power delivery. All components meet RoHS environmental standards.

What is included in the package?

The package contains the MBP30A5 maintenance bypass panel, a 6-foot utility cord, a 3.3-foot UPS cord, two rackmount brackets, mounting screws (four M4X8L flat head and four M5X12L pan head), a user manual, and a registration card for warranty activation.

What power capacity is listed for this UPS?

Power specifications help show where CyberPower MBP30A5 MBP30A5120V 30A Maintenance Bypass Panel - 5 Outlets - 6ft Cord - NEMA L5-30P - 1U Rack Mount fits best, including the kind of load level, electrical environment, and backup role it is intended to support.

What runtime or backup profile is mentioned?

CyberPower MBP30A5 MBP30A5120V 30A Maintenance Bypass Panel - 5 Outlets - 6ft Cord - NEMA L5-30P - 1U Rack Mount should be evaluated around its backup-runtime profile, power capacity, and outlet layout so buyers can judge whether it fits workstation, networking, or edge-protection needs.

[/custom-faq]
Volume Discounts
Qty Price Available
Match Price Request

Found a lower price? Send us the link and we will do our best to match or beat it.

Request received. We will reply within 24 hours.
Fleet Network
Wholesale & B2B
Partner with Us

Looking to buy in bulk? We offer competitive pricing, dedicated support, and custom solutions for businesses of all sizes.

Volume Discounts

Tiered pricing structure designed to maximize your margins as you grow.

Dedicated Account Manager

Direct access to a specialist who understands your business needs.

Fast & Reliable Shipping

Priority processing and discounted shipping rates for bulk orders.

Request a Quote
Thank you!
Your request has been sent successfully.
CyberPower MBP30A5 30A Maintenance Bypass Panel - 5 Outlets - 1U Rack Mount - 120V AC - 6ft Cord
MSRP: $596.99
$596.99
$542.99
Save: $54.00 (9.05%)
Out of stock