CyberPower PDU13103 Basic 3-Phase PDU - 42 Outlets - 5. 7kW - 200-240V AC - 20A - NEMA L21-20P - 0U Vertical Rackmount - 10 ft Cord
Business volume discounts
Technical guidance
Preparation & staging
QC · ON · AB · BC
Product Features
Technical Overview
This PDU operates on a three-phase electrical system, accepting an input voltage range of 200-240V AC and delivering the same output range to connected equipment. The 5.70 kW power rating and 20A input current define its capacity for supporting multiple high-draw devices simultaneously. The outlet array consists of 36 IEC 60320 C13 receptacles and 6 IEC 60320 C19 receptacles, catering to standard server power cords and higher-current devices respectively.
Electrical protection is inherent in its basic design, providing reliable power distribution without voltage regulation or surge suppression. The unit is built for 50/60Hz operation, ensuring compatibility with common North American power grids. Its derated 16A operational current enhances safety and longevity under continuous load conditions.
This section brings together practical product details such as PDU Type, Phase, Plug/Connector Type, Input Voltage, so buyers can judge configuration, deployment fit, and day-to-day suitability with less guesswork.
Key Product Advantages
The PDU13103 excels in maximizing rack space efficiency while delivering substantial power capacity. Its 0U vertical mounting requires no rack units, preserving horizontal space for servers and switches. The 42-outlet configuration, with dedicated C19 ports for high-power equipment, supports dense deployments without requiring additional PDUs.
The 10-foot input cord offers installation flexibility, allowing the PDU to be positioned optimally within the rack. Adjustable mounting brackets accommodate various rack depths, while the vertical orientation improves cable management by keeping power cords organized along the rack's side. The basic, non-metered design ensures reliability with minimal points of failure, ideal for environments where simplicity and uptime are priorities.
High-Density Power Distribution
With 42 outlets in a compact vertical form, this PDU powers an entire rack of equipment, reducing clutter and the need for multiple power strips.
- 36 C13 outlets for standard servers
- 6 C19 outlets for high-power devices
- Consolidates power connections efficiently
Space-Saving Vertical Design
The 0U vertical mount installs on the rack's side posts, freeing all horizontal U-space for active equipment and improving airflow.
- No rack units consumed
- Fits standard 19-inch racks
- Keeps cables organized vertically
Deployment / Use Cases
This PDU is ideal for data centers, server rooms, and network closets where rack space is at a premium and basic, reliable power distribution is required. Its 3-phase input makes it suitable for commercial buildings with three-phase power infrastructure, supporting higher power loads than single-phase alternatives. The unit is commonly deployed in racks containing multiple servers, storage arrays, and networking switches that demand numerous power connections.
Telecom installations and broadcast facilities also benefit from its high outlet count and vertical form factor, allowing clean cable runs alongside equipment. The PDU13103 serves as a foundational power distribution layer in environments where advanced monitoring isn't necessary, but robust connectivity and space efficiency are essential. It's particularly valuable in colocation settings where rack density and power capacity directly impact operational costs.
Enterprise Data Center Racks
Deploy in full-height server racks to power blade chassis, SANs, and top-of-rack switches, leveraging the 5.7 kW capacity for high-density computing.
Network and Telecom Cabinets
Use in communication racks to distribute power to routers, switches, and patch panels, with the vertical mount preserving space for networking hardware.
Physical Profile
The PDU13103 features a slim, vertical design measuring 70.50" in height, 2.20" in width, and 2.20" in depth, allowing it to mount neatly on rack side rails without protruding. Its 0U rack height means it occupies no rack units horizontally, maximizing space for servers and other equipment. The unit weighs approximately 12.61 lb, making it manageable for installation while remaining sturdy enough for rack mounting.
Constructed in black to blend with typical rack hardware, it includes adjustable mounting brackets to fit various rack depths. The vertical orientation aids cable management by running power cords parallel to the rack frame, reducing clutter and improving airflow. The 10-foot input cord provides reach to distant power sources, accommodating flexible rack placement within the room.
- Width
- 2.20" (55.88 mm)
- Depth
- 2.20" (55.88 mm)
- Height
- 0U
- Weight
- 12.61 lb (5720 g)
What's in the Box
The package includes the PDU13103 42-outlet power distribution unit and adjustable mounting brackets for secure rack installation. All necessary hardware for mounting is provided, ensuring quick deployment in standard 19-inch rack environments.
Highlights
- Basic 3-phase PDU with 5.7 kW power capacity
- 42 total outlets: 36 IEC C13 and 6 IEC C19 receptacles
- 200-240V AC input range with 20A NEMA L21-20P plug
- 0U vertical rackmount design saves horizontal rack space
- Vertical mounting orientation for improved cable management
- 10-foot input cord for flexible installation
- RoHS compliant and environmentally friendly
- Backed by a 3-year limited warranty
Specifications
| Specifications | |
|---|---|
| Manufacturer | CyberPower Systems, Inc |
| Manufacturer Part Number | PDU13103 |
| Brand Name | CyberPower |
| Product Model | PDU13103 |
| Product Name | PDU13103 3 Phase 200 - 240 VAC 20A Basic |
| Product Type | PDU |
| Technical Information | |
| PDU Type | Basic |
| Phase | Three Phase |
| Plug/Connector Type | NEMA L21-20P |
| Receptacle Type | IEC 60320 C13,IEC 60320 C19 |
| Receptacle Detail | 36 x IEC 60320 C13,6 x IEC 60320 C19 |
| Power Description | |
| Input Voltage | 230 V AC |
| Input Voltage Range | 200 V AC - 240 V AC |
| Output Voltage | 200 V AC,240 V AC |
| Output Voltage Range | 200 V AC - 240 V AC |
| Power Rating (Watt) | 5.70 kW |
| Input Current | 20 A |
| Physical Characteristics | |
| Color Family | Black |
| Product Color | Black |
| Mounting Orientation | Vertical |
| Mount Type | Rack-mountable |
| Rack Height | 0U |
| Height | 70.50" (1790.70 mm) |
| Width | 2.20" (55.88 mm) |
| Depth | 2.20" (55.88 mm) |
| Weight (Approximate) | 12.61 lb (5720 g) |
| Miscellaneous | |
| Package Contents | PDU13103 42-Outlets PDU Adjustable Mounting Brackets |
| Environmentally Friendly | Yes |
| Environmental Compliance | Restriction of Hazardous Substances (RoHS) |
| Warranty | |
| Limited Warranty | 3 Year |
User Manual
FAQ
What is the power capacity of the CyberPower PDU13103?
The PDU13103 has a power rating of 5.70 kW (5700 watts). This capacity supports multiple high-draw devices simultaneously, making it suitable for dense server racks and networking equipment in data center environments.
How many outlets does this PDU have and what types are they?
This PDU features 42 outlets total: 36 IEC 60320 C13 receptacles for standard server and network gear power cords, and 6 IEC 60320 C19 receptacles for higher-current devices like some servers and storage arrays. This mix accommodates a wide range of equipment in a rack.
What type of electrical input does the PDU13103 require?
The PDU requires a three-phase 200-240V AC input with a 20A NEMA L21-20P plug. It operates on 50/60Hz power, making it compatible with standard commercial and data center power infrastructures in North America.
How is this PDU mounted in a rack?
It uses a 0U vertical mounting design, meaning it installs on the side rails of a standard 19-inch rack without consuming any horizontal rack units. The included adjustable mounting brackets secure it vertically, preserving all U-space for servers and switches.
What is the length of the power cord?
The input power cord is 10 feet long, providing flexibility in rack placement relative to power sources. This length helps accommodate various data center layouts and reduces the need for extension cords.
Does this PDU include any warranty or environmental certifications?
Yes, it comes with a 3-year limited warranty from CyberPower. It is also RoHS (Restriction of Hazardous Substances) compliant and marked as environmentally friendly, meeting modern regulatory standards for electronic equipment.
What power capacity is listed for this UPS?
The listed power specification is 5.70 kW, which helps position the unit for the right load level and installation role.
What voltage details are listed?
The listed power specification is 230 V AC, which helps position the unit for the right load level and installation role.