Product Features
Technical Overview
This Eaton 5PX G2 model operates as a line-interactive UPS, offering voltage regulation and battery backup without full double conversion. It accepts 120V AC input at 60Hz via a NEMA L6-20P plug and provides conditioned output through ten IEC receptacles: eight IEC 60320 C13 outlets and two higher-capacity IEC 60320 C19 outlets. This outlet mix supports a broad range of server, network, and storage equipment.
The sealed lead-acid battery is user-replaceable, supporting maintenance and lifecycle management. A USB HID-compliant port enables communication with connected systems for graceful shutdowns and monitoring via supported software. The unit carries ENERGY STAR 2.0 certification, reflecting its energy-efficient design that reduces operational costs and environmental impact.
This section brings together practical product details such as Plug/Connector Type, Receptacle Type, Receptacle Detail, Load Capacity (VA), so buyers can judge configuration, deployment fit, and day-to-day suitability with less guesswork.
Key Product Advantages
The 5PX G2 UPS combines robust power protection with rack-optimized design, making it a dependable choice for business continuity. Its intelligent features and scalable runtime options provide a future-ready foundation for critical infrastructure.
High-Density Outlet Configuration
Ten IEC outlets (8x C13, 2x C19) allow direct connection of multiple devices without external PDUs, simplifying cable management and reducing points of failure in rack deployments.
- Supports mixed equipment loads
- Eliminates need for additional power strips
Rack-Ready Design
The 2U form factor includes integrated four-post rail mounting hardware, ensuring secure installation in standard 19-inch racks. Tower pedestal feet are included for optional standalone use.
- Includes four-post rail kit
- Pedestal feet for flexibility
Environmental Compliance
Manufactured in compliance with REACH and RoHS regulations, the unit avoids hazardous substances and supports corporate sustainability initiatives alongside its ENERGY STAR certification.
- RoHS and REACH compliant
- Reduces environmental impact
Deployment / Use Cases
This UPS is engineered for environments where space efficiency and reliable power are non-negotiable. Its 3 kVA capacity and rack-mount design make it ideal for network closets, server rooms, and small data centers protecting consolidated IT loads.
Typical protected equipment includes rack-mounted servers, storage arrays, network switches, VoIP systems, and telecommunications gear. The 6-minute runtime at full load provides sufficient time for automated shutdown procedures or transfer to backup generators during extended outages. For longer runtime needs, external battery modules can be added without replacing the core unit.
Server & Network Infrastructure
Deploy in racks housing 1-2 standard servers plus associated networking and storage equipment, ensuring uninterrupted operation during brief power events and safe shutdown during prolonged outages.
Edge Computing & Remote Sites
Provide reliable power for IT equipment in branch offices, retail locations, or telecommunications cabinets where space is limited and uptime is critical for business operations.
Physical Profile
The UPS features a standard 19-inch rack width of 17.2 inches and a depth of 23.7 inches, compatible with most four-post server racks. Its 2U height (3.4 inches) conserves valuable vertical space. The black finish blends with typical rack equipment. At approximately 70 pounds, it requires proper handling during installation. The included four-post rail kit facilitates secure mounting, while the tower pedestal feet offer placement flexibility for temporary or standalone setups.
- Width
- 17.20" (436.88 mm)
- Depth
- 23.70" (601.98 mm)
- Height
- 3.40" (86.36 mm)
- Weight
- 69.90 lb (31706.11 g)
What's in the Box
The package includes all necessary components for immediate deployment in rack or tower configurations.
Highlights
- 3 kVA / 3 kW line-interactive UPS for critical IT equipment protection
- 2U rack-mountable form factor with included four-post rail kit
- 6-minute runtime at full load (3000W) from internal batteries
- 10 output outlets: 8x IEC C13 and 2x IEC C19 for versatile connectivity
- 120V AC, 60Hz input via NEMA L6-20P plug
- LCD graphical display for clear status and configuration monitoring
- USER-replaceable sealed lead-acid battery for easy maintenance
- ENERGY STAR 2.0 certified for energy efficiency and cost savings
- Supports optional external battery modules for extended runtime
- 3-year limited warranty for long-term reliability assurance
Specifications
| Specifications | |
|---|---|
| Manufacturer | Eaton Corporation |
| Manufacturer Part Number | 5PX3000HRTG2 |
| Brand Name | Eaton |
| Product Series | 5PX G2 |
| Product Name | 5PX G2 UPS |
| Product Type | Line-interactive UPS |
| Technical Information | |
| Plug/Connector Type | NEMA L6-20P |
| Receptacle Type | IEC 60320 C13,IEC 60320 C19 |
| Receptacle Detail | 8 x IEC 60320 C13,2 x IEC 60320 C19 |
| Application/Usage | Server,Storage System,VoIP,Network Equipment,Switch,IT Equipment,Enterprise,Telecommunication,Retail Building,Bank,Business |
| Power Description | |
| Load Capacity (VA) | 3 kVA |
| Load Capacity (Watt) | 3 kW |
| Input Voltage | 120 V AC |
| Input Frequency | 60 Hz |
| Controls/Indicators | |
| Status Indicators | LCD Graphical Display |
| Interfaces/Ports | |
| USB (HID Compliant) Port | Yes |
| Battery Information | |
| Battery Characteristics | Sealed |
| Battery Chemistry | Lead Acid |
| Backup/Run Time (Full Load) | 6 Minute |
| Replaceable Battery | Yes |
| Physical Characteristics | |
| Product Color | Black |
| Height | 3.40" (86.36 mm) |
| Width | 17.20" (436.88 mm) |
| Depth | 23.70" (601.98 mm) |
| Rack Height | 2U |
| Form Factor | Rack-mountable |
| Weight (Approximate) | 69.90 lb (31706.11 g) |
| Miscellaneous | |
| Package Contents | 5PX G2 UPS Tower Pedestal Feet Four-post Rail Kit Quick Start Guide Safety Guide USB Cable RS-232 Cable 2 x IEC C13 to IEC C14 Jumper Cables |
| Energy Star | Yes |
| Country of Origin | Philippines |
| Environmentally Friendly | Yes |
| Environmental Compliance | Registration, Evaluation, Authorization and Restriction of Chemicals (REACH),Restriction of Hazardous Substances (RoHS) |
| Warranty | |
| Limited Warranty | 3 Year |
User Manual
FAQ
What is the power capacity of this Eaton UPS?
The Eaton 5PX G2 UPS provides 3 kVA (3000 volt-amps) and 3 kW (3000 watts) of power capacity. This rating indicates the maximum load it can support while providing battery backup and power conditioning. The unity power factor design ensures the full 3 kW is available for connected equipment, making it suitable for protecting servers, storage, and networking gear with similar power draws.
How long will this UPS run on battery power?
At its full rated load of 3 kW, the internal batteries provide approximately 6 minutes of runtime. This duration allows sufficient time for connected systems to perform graceful shutdowns via software or for an operator to initiate manual procedures during a power outage. Runtime increases significantly at lower loads, and optional external battery modules can be added to extend backup time for longer outages.
What types of equipment outlets does it have?
This UPS features ten IEC output receptacles: eight are standard IEC 60320 C13 outlets (commonly used for servers, switches, and monitors) and two are higher-current IEC 60320 C19 outlets (often used for power-hungry devices like some servers or PDUs). This mix supports direct connection of a variety of rack-mounted IT equipment without requiring additional power distribution units.
Is this UPS designed for rack mounting?
Yes, the Eaton 5PX G2 is a 2U rack-mountable UPS. It has a standard 19-inch width and includes a four-post rail kit in the box for secure installation in server racks. The unit can also be used as a tower with the included pedestal feet, offering deployment flexibility for environments where rack space is not immediately available.
What input power connection does it use?
The UPS requires a 120-volt AC, 60Hz power source and connects via a NEMA L6-20P plug. This is a locking 20-amp plug commonly used for higher-power equipment. Ensure your facility has a compatible 120V, 20A outlet (typically an L6-20R receptacle) available to power the unit. It is not designed for 208/240V input or other plug types without a separate adapter.
Can the battery be replaced by the user?
Yes, the sealed lead-acid battery is user-replaceable. This allows for easy maintenance and extends the operational life of the UPS without requiring a full unit replacement or professional service. Eaton provides guidance on compatible replacement battery packs. The unit's design facilitates safe battery swaps, supporting long-term reliability and lower total cost of ownership.
What power capacity is listed for this UPS?
The listed power specification is 3 kVA, which helps position the unit for the right load level and installation role.
What voltage details are listed?
The listed power specification is 120 V AC, which helps position the unit for the right load level and installation role.