Shipping included*
Exclusions
Additional shipping fees may apply in rare circumstances for deliveries outside standard service areas. In most cases, this only potentially affects shipments to the Northwest Territories and Yukon, as well as certain heavy or oversized items.
Eaton 9PX3K3UG2 9PX G2 3000VA Rack/Tower UPS - 3 kVA/3 kW - 3U - 230V AC Input - Pure Sine Wave
Business volume discounts
Technical guidance
Preparation & staging
QC · ON · AB · BC
Product Features
Technical Overview
This UPS employs a double-conversion online topology, continuously conditioning incoming power to deliver a stable, isolated output. It achieves high operational efficiency, rated at 96.1% in AC mode and 98.3% in Eco mode, helping to reduce energy costs and thermal load.
The system integrates advanced battery management (ABM+) to prolong battery life and supports hot-swappable, valve-regulated lead-acid batteries. A comprehensive LCD display and LED indicators provide clear system status, while multiple communication ports—including serial, USB, and an EPO port—enable integration into broader facility management systems.
This section brings together practical product details such as Plug/Connector Type, Receptacle Type, Receptacle Detail, Load Capacity (VA), so buyers can judge configuration, deployment fit, and day-to-day suitability with less guesswork.
A strong technical summary explains how the product's interfaces, hardware profile, and operating characteristics work together in real deployment. Buyers often need this context to confirm compatibility with existing devices, expected performance in daily use, and whether installation will be straightforward for IT staff or end users.
Key Product Advantages
The 9PX G2 series is built for reliability and manageability in demanding IT infrastructures. Its design prioritizes uptime, equipment protection, and operational transparency for administrators.
High-Capacity Power Protection
With 3000VA/3000W capacity, this UPS can support multiple servers, network switches, and storage arrays, providing a critical buffer against power outages and anomalies.
- 3 kVA/3 kW load capacity
- 230V AC input with 15.30A current
- Configurable output voltage range
Intelligent Battery Management
Advanced Battery Management (ABM+) technology optimizes charging cycles and monitors battery health, while hot-swappable design allows for maintenance without system downtime.
- Hot-swappable battery modules
- 3-hour typical recharge time
- Valve-regulated lead-acid chemistry
Comprehensive Monitoring & Control
An LCD interface, network management card support, and multiple alarm conditions give IT staff full visibility and control over power status and UPS health.
- LCD display with status indicators
- Support for Network-M3, INDGW-M2, Relay-MS cards
- Audible alarms for power events
Deployment / Use Cases
This UPS is engineered for environments where power continuity directly impacts business operations and data integrity. Its rack/tower versatility and robust power rating make it a fit for centralized and distributed IT deployments.
In a data center, it can be integrated into a 3U rack space to protect a blade enclosure or a cluster of servers. For edge computing locations or network closets, the tower configuration offers a standalone power solution for switches, routers, and security appliances.
Data Center & Server Room Backup
Provides clean, uninterrupted power to server racks, storage arrays, and core network equipment, safeguarding against data loss and hardware damage during outages.
Edge & Network Infrastructure Support
Ideal for remote offices, retail locations, or healthcare facilities where IT equipment must remain operational through brief power interruptions.
Physical Profile
The unit features a compact 3U rack-mount footprint with dimensions of 5.10" H x 17.30" W x 27" D (129.54 mm x 439.42 mm x 685.80 mm), optimized for standard 19-inch equipment racks. Tower support stands are included for standalone use. With a weight of approximately 98.30 lb (44.6 kg), it is designed for stable installation in both configurations.
- Width
- 17.30" (439.42 mm)
- Depth
- 27" (685.80 mm)
- Height
- 5.10" (129.54 mm)
- Weight
- 98.30 lb (44588.13 g)
- Length
- 10 ft (3.05 m)
What's in the Box
The package includes all necessary components for immediate deployment in rack or tower mode, along with essential connectivity and management accessories.
Highlights
- 3000VA/3000W double-conversion online UPS for high-density IT equipment
- Pure sine wave output ensures compatibility with sensitive servers and networking gear
- Flexible 3U rack-mount or tower deployment to suit data center and edge environments
- Hot-swappable battery design allows for maintenance without powering down connected loads
- Advanced Battery Management (ABM+) extends battery life and monitors health
- LCD display and support for multiple network management cards (Network-M3, INDGW-M2, Relay-MS)
- Configurable output voltages (200-250V AC) and frequencies (50/60 Hz) for global use
- Includes rack-mount hardware and tower stands for versatile installation
- Energy Star certified and RoHS compliant for energy efficiency and environmental safety
- Backed by a 3-year limited warranty from Eaton
Specifications
| Specifications | |
|---|---|
| Manufacturer | Eaton Corporation |
| Manufacturer Part Number | 9PX3K3UG2 |
| Brand Name | Eaton |
| Product Series | 9PX G2 |
| Product Model | 9PX3K3UG2 |
| Product Name | 9PX G2 9PX3K3UG2 3000VA Rack/tower UPS |
| Product Type | Double Conversion Online UPS |
| Technical Information | |
| Plug/Connector Type | NEMA L6-30P,Hardwired |
| Receptacle Type | NEMA L6-20R,NEMA L6-30R,Hardwired |
| Receptacle Detail | 2 x NEMA L6-20R,2 x NEMA L6-30R |
| Cord Length | 10 ft (3.05 m) |
| EMI/RFI Noise Filter | Yes |
| Phase | Single Phase |
| Efficiency Detail | 96.1% (AC Mode),98.3% (Eco Mode) |
| Application/Usage | Mission Critical Equipment,Network,IT Equipment,Data Center,Electronic,Edge Computing,Education,Government,Healthcare,Retail,Server,Switch,Network Equipment |
| Surge Suppression | Yes |
| Features | Audible Alarm,Advanced Battery Management (ABM+) |
| Power Description | |
| Load Capacity (VA) | 3 kVA |
| Load Capacity (Watt) | 3 kW |
| Input Voltage | 230 V AC |
| Input Current | 15.30 A |
| Output Voltage | 240 V AC,230 V AC,220 V AC,208 V AC,200 V AC,250 V AC |
| Output Frequency | 50 Hz,60 Hz |
| Waveform Type | Pure Sine Wave |
| Output Power Factor | 1 |
| Display & Graphics | |
| Display | LCD |
| Management | |
| Network Management | Network-M3 Card,INDGW-M2 Card,Relay-MS Card |
| Alarm | Utility Power Failure,Low Battery,Overload,UPS Fault,Battery Fault,Remote Shutdown |
| Controls/Indicators | |
| Status Indicators | LED Indicators |
| Interfaces/Ports | |
| Serial Port | Yes |
| USB | Yes |
| EPO Port | Yes |
| Battery Information | |
| DC System Voltage | 180 V DC |
| Battery Characteristics | Valve-regulated |
| Battery Chemistry | Lead Acid |
| Backup/Run Time (Full Load) | 7.50 Minute |
| Backup/Run Time (Half Load) | 18.50 Minute |
| Hot Swappable | Yes |
| Typical Battery Recharge Time | 3 Hour |
| Replaceable Battery | Yes |
| Environmental Conditions | |
| Minimum Operating Temperature | 32°F (0°C) |
| Maximum Operating Temperature | 104°F (40°C) |
| Thermal Dissipation | 471 BTU/h |
| Physical Characteristics | |
| Height | 5.10" (129.54 mm) |
| Width | 17.30" (439.42 mm) |
| Depth | 27" (685.80 mm) |
| Rack Height | 3U |
| Form Factor | Rack/Tower |
| Weight (Approximate) | 98.30 lb (44588.13 g) |
| Miscellaneous | |
| Package Contents | 9PX G2 9PX3K3UG2 3000VA Rack/tower UPS NETWORK-M3 Gigabit Network Card USB Cable RS-232 Cable Cable Gland for Hardwire Connection Rack-mounting Hardware Tower Support Stands Quick Start Guide |
| Energy Star | Yes |
| Country of Origin | Philippines |
| Environmental Compliance | Restriction of Hazardous Substances (RoHS) |
| Warranty | |
| Limited Warranty | 3 Year |
User Manual
FAQ
What is the power capacity of this Eaton UPS?
This Eaton 9PX G2 UPS has a load capacity of 3000 volt-amps (3 kVA) and 3000 watts (3 kW). This rating indicates it can support a substantial amount of IT equipment, such as multiple servers, network switches, and storage devices, providing reliable backup power during an outage.
How long will the UPS run on battery during a power failure?
The runtime depends on the connected load. At full load (3000W), the battery backup runtime is 7.50 minutes. At half load (1500W), the runtime extends to 18.50 minutes. These times provide a critical window for connected systems to perform orderly shutdowns or ride through short interruptions.
Can this UPS be installed in a server rack?
Yes, this UPS is designed for flexible installation. It has a 3U rack-mount form factor and includes all necessary rack-mounting hardware. It can also be used as a standalone tower using the included support stands, making it suitable for both data center racks and office environments.
What type of power output does this UPS provide?
The UPS delivers a pure sine wave output, which is essential for the safe and efficient operation of sensitive electronic equipment like servers, networking hardware, and medical devices. It ensures compatibility and prevents potential damage or instability that can occur with simulated sine wave outputs.
How is the UPS monitored and managed?
Management is facilitated through an onboard LCD display, LED status indicators, and support for optional network management cards like the Network-M3, INDGW-M2, or Relay-MS cards. It also includes serial and USB ports for local communication and an EPO (Emergency Power Off) port for safety integration.
What is included in the box with the UPS?
The package contains the 9PX G2 UPS unit, a NETWORK-M3 Gigabit Network Card, a USB cable, an RS-232 cable, a cable gland for hardwire connections, rack-mounting hardware, tower support stands, and a quick start guide. This allows for immediate deployment in either rack or tower configuration.
What power capacity is listed for this UPS?
The listed power specification is 3 kVA, which helps position the unit for the right load level and installation role.
What voltage details are listed?
The listed power specification is 230 V AC, which helps position the unit for the right load level and installation role.