Shipping included*
Exclusions
Additional shipping fees may apply in rare circumstances for deliveries outside standard service areas. In most cases, this only potentially affects shipments to the Northwest Territories and Yukon, as well as certain heavy or oversized items.
Eaton EMI356-10 ePDU Metered PDU - 60 Outlets - 48x C13 - 12x C19 - 17. 3 kW - 230/400V AC - Three Phase - 0U Rack-Mount
Business volume discounts
Technical guidance
Preparation & staging
QC · ON · AB · BC
Product Features
Technical Overview
This Eaton ePDU features a robust electrical design with a 24 A input current and an output voltage range of 200-240 V AC, ensuring stable power delivery to connected devices. The unit includes circuit protection to safeguard against electrical faults, enhancing reliability in demanding operational settings.
Network management is facilitated through an RJ-45 port, enabling remote monitoring and control of power distribution. The PDU's metered capabilities provide detailed insights into power usage, helping organizations optimize energy efficiency and plan for capacity upgrades.
This section brings together practical product details such as PDU Type, Phase, Plug/Connector Type, Input Voltage, so buyers can judge configuration, deployment fit, and day-to-day suitability with less guesswork.
A strong technical summary explains how the product's interfaces, hardware profile, and operating characteristics work together in real deployment. Buyers often need this context to confirm compatibility with existing devices, expected performance in daily use, and whether installation will be straightforward for IT staff or end users.
Key Product Advantages
The Eaton EMI356-10 ePDU combines high outlet density with advanced monitoring features, making it an ideal solution for modern data centers. Its 60-outlet configuration includes 48 IEC C13 and 12 IEC C19 receptacles, accommodating a wide range of server, storage, and networking equipment without the need for additional PDUs.
High-Density Power Distribution
With 60 outlets in a compact 0U form factor, this PDU maximizes power availability in space-constrained racks, reducing clutter and simplifying cable management.
- 48 x IEC C13 outlets for standard equipment
- 12 x IEC C19 outlets for high-power devices
Remote Monitoring & Control
Network connectivity via RJ-45 allows IT staff to monitor power loads remotely, set alerts for thresholds, and manage power distribution without physical access to the rack.
- Real-time load monitoring
- Prevent overloads proactively
Deployment / Use Cases
This metered ePDU is designed for deployment in data centers, server rooms, and network closets where reliable power distribution and monitoring are critical. Its 17.3 kW capacity and three-phase input make it suitable for supporting high-density server racks, storage arrays, and networking gear in enterprise and colocation environments.
Typical use cases include powering multiple 1U or 2U servers, blade chassis, network switches, and storage systems within a single rack. The vertical 0U mounting saves valuable rack space for additional equipment, while the network management features integrate with existing data center infrastructure management (DCIM) tools for comprehensive oversight.
Data Center Racks
Ideal for consolidating power distribution in server racks, reducing the number of PDUs needed and improving airflow management.
- Supports high-power compute nodes
- Fits standard 19-inch racks
Network Operations Centers
Enables centralized power monitoring for critical network infrastructure, ensuring uptime and facilitating capacity planning.
- Remote load tracking
- Alerts for power anomalies
Physical Profile
The Eaton EMI356-10 ePDU features a vertical rack-mount design with a 0U height, mounting directly onto rack rails without consuming usable rack space. Its dimensions of 2.09 inches high, 4.10 inches wide, and 63.20 inches deep provide a slim profile that fits seamlessly into standard server racks. The unit weighs approximately 16.5 pounds, making it manageable for installation while remaining sturdy during operation. The vertical orientation optimizes cable routing and airflow, contributing to improved thermal management within the rack environment.
- Width
- 4.10" (104.14 mm)
- Depth
- 63.20" (1605.28 mm)
- Height
- 0U
- Weight
- 16.50 lb (7484.27 g)
Highlights
- 60 total outlets: 48 IEC C13 and 12 IEC C19 for versatile device connectivity
- 17.3 kW power rating with three-phase 230/400V AC input for high-density loads
- Metered functionality with network monitoring via RJ-45 for remote power management
- 0U vertical rack-mount design saves space in standard server racks
- Circuit protection enhances reliability and safeguards connected equipment
- Output voltage range of 200-240 V AC ensures stable power delivery
- Manufactured in the United States and TAA compliant for government contracts
- Backed by a 3-year limited warranty for long-term peace of mind
Specifications
| Specifications | |
|---|---|
| Manufacturer | Eaton Corporation |
| Manufacturer Part Number | EMI356-10 |
| Brand Name | Eaton |
| Product Line | ePDU |
| Product Name | ePDU 60-Outlets PDU |
| Product Type | PDU |
| Technical Information | |
| PDU Type | Metered |
| Phase | Three Phase |
| Plug/Connector Type | 309-532P6W |
| Plug/Connector Detail | 1 x 309-532P6W |
| Receptacle Type | IEC 60320 C13,IEC 60320 C19 |
| Receptacle Detail | 48 x IEC 60320 C13,12 x IEC 60320 C19 |
| Protection Type | Circuit Protection |
| Power Description | |
| Input Voltage | 230 V AC,400 V AC |
| Output Voltage Range | 200 V AC - 240 V AC |
| Power Rating (Watt) | 17.30 kW |
| Input Current | 24 A |
| Interfaces/Ports | |
| Network (RJ-45) | Yes |
| Physical Characteristics | |
| Mounting Orientation | Vertical |
| Mount Type | Rack-mountable |
| Rack Height | 0U |
| Height | 2.09" (53.09 mm) |
| Width | 4.10" (104.14 mm) |
| Depth | 63.20" (1605.28 mm) |
| Weight (Approximate) | 16.50 lb (7484.27 g) |
| Miscellaneous | |
| Country of Origin | United States |
| TAA Compliant | Yes |
| Warranty | |
| Limited Warranty | 3 Year |
User Manual
FAQ
What is the total power capacity of this Eaton ePDU?
The Eaton EMI356-10 ePDU has a power rating of 17.30 kW (17,300 watts). This high capacity supports demanding loads in data center environments, making it suitable for powering multiple servers, storage devices, and networking equipment within a single rack.
How many outlets does this PDU have, and what types are included?
This PDU features 60 outlets total: 48 IEC 60320 C13 receptacles and 12 IEC 60320 C19 receptacles. The C13 outlets are standard for most IT equipment, while the C19 outlets accommodate higher-power devices such as servers or UPS units, providing flexibility for diverse hardware configurations.
What input voltages does this Eaton ePDU support?
The Eaton EMI356-10 ePDU supports three-phase input voltages of 230 V AC and 400 V AC. This dual-voltage capability allows it to integrate with various power infrastructures, ensuring compatibility in different data center setups and regions.
How is this PDU mounted in a server rack?
This PDU is designed for vertical rack mounting with a 0U height, meaning it mounts directly onto the rack rails without consuming any usable rack units (U). Its slim profile of 2.09 inches high by 4.10 inches wide fits neatly alongside equipment, optimizing space and improving cable management.
What network management features does this metered ePDU offer?
The Eaton EMI356-10 ePDU includes an RJ-45 port for network connectivity, enabling remote monitoring and control. This allows IT administrators to track real-time power consumption, set load alerts, and manage power distribution via network-based tools, enhancing operational efficiency and preventing overloads.
What warranty coverage is provided with this Eaton ePDU?
Eaton provides a 3-year limited warranty for the EMI356-10 ePDU. This warranty covers defects in materials and workmanship, offering reliable support for long-term use in critical power distribution applications. The product is also TAA compliant, making it suitable for government and institutional procurement.
What power capacity is listed for this UPS?
The listed power specification is 17.30 kW, which helps position the unit for the right load level and installation role.
What voltage details are listed?
The listed power specification is 230 V AC,400 V AC, which helps position the unit for the right load level and installation role.