Shipping included*
Exclusions
Additional shipping fees may apply in rare circumstances for deliveries outside standard service areas. In most cases, this only potentially affects shipments to the Northwest Territories and Yukon, as well as certain heavy or oversized items.
Eaton EMA115-10 ePDU G3 Managed 36U Rack PDU - Switched - 3. 84 kW - 16A - 24 Outlets - 21xC13 - 3xC19 - NEMA L6-20P/C20 Input
Business volume discounts
Technical guidance
Preparation & staging
QC · ON · AB · BC
Product Features
Technical Overview
This ePDU operates as a switched PDU type, providing granular control over power distribution. The input accepts a NEMA L6-20P or IEC C20 plug, delivering power through a single-phase configuration. Output voltage matches the input at 120V or 230V AC, with an input voltage range of 120-230V AC for stable operation across different power infrastructures.
Network connectivity is enabled via an RJ-45 port, allowing integration into existing management systems for real-time monitoring and remote rebooting of connected devices. The unit's 3.84 kW power rating ensures it can handle high-density server racks without performance degradation.
This section brings together practical product details such as PDU Type, Plug/Connector Type, Plug/Connector Detail, Input Voltage, so buyers can judge configuration, deployment fit, and day-to-day suitability with less guesswork.
A strong technical summary explains how the product's interfaces, hardware profile, and operating characteristics work together in real deployment. Buyers often need this context to confirm compatibility with existing devices, expected performance in daily use, and whether installation will be straightforward for IT staff or end users.
Key Product Advantages
The EMA115-10 combines high power capacity with intelligent management features that optimize data center efficiency and reliability. Its switched design prevents potential overloads by allowing administrators to monitor current draw per outlet and remotely power cycle equipment without physical access.
Remote Power Management
Control individual outlets via network interface for load balancing, reducing extra costs from over-provisioning and minimizing downtime through remote rebooting capabilities.
- Outlet-level monitoring
- Remote power cycling
- Load balancing tools
High-Density Compatibility
With 24 outlets in a 36U form factor, this PDU supports dense server deployments while maintaining clean cable management through vertical mounting.
- 24-outlet capacity
- Vertical space efficiency
- Mixed connector types
Deployment / Use Cases
This managed PDU is engineered for environments where power control and monitoring are critical to operations. Data centers benefit from its ability to manage power distribution across server racks, while network operations centers use the remote management features to maintain uptime for critical infrastructure.
Enterprise server rooms deploying high-density blade servers or storage arrays will appreciate the 3.84 kW capacity and C19 outlets for power-hungry equipment. The vertical 36U mounting makes it ideal for standard server racks where horizontal space is limited, providing full-height power distribution without consuming valuable equipment U-space.
This section brings together practical product details such as PDU Type, Plug/Connector Type, Plug/Connector Detail, Input Voltage, so buyers can judge configuration, deployment fit, and day-to-day suitability with less guesswork.
Physical Profile
Designed for vertical rack mounting, this PDU occupies 36U of rack height with dimensions of 63.10" (1602.74 mm) height, 2.05" (52.07 mm) width, and 2.09" (53.09 mm) depth. The slim profile maximizes equipment space while providing full-length power distribution. Vertical orientation improves cable management and airflow compared to horizontal PDUs.
The physical profile is practical for deployment planning because the dimensions and weight are clearly defined: 36U, 2.05" (52.07 mm), 2.09" (53.09 mm). This helps confirm rack, shelf, desk, or cabinet fit before installation.
- Width
- 2.05" (52.07 mm)
- Depth
- 2.09" (53.09 mm)
- Height
- 36U
What's in the Box
The package includes the complete PDU system with necessary components for installation and maintenance.
Highlights
- Switched PDU with remote outlet management and monitoring
- 3.84 kW power capacity with 16A input current
- 24 total outlets: 21 IEC C13 and 3 IEC C19 receptacles
- Dual voltage input: 120V and 230V AC operation
- Vertical 36U rack-mountable design for space efficiency
- Network management via RJ-45 port for integration
- Built-in digital current meter for overload prevention
- 3-year limited warranty for reliable operation
Specifications
| Specifications | |
|---|---|
| Manufacturer | Eaton Corporation |
| Manufacturer Part Number | EMA115-10 |
| Brand Name | Eaton |
| Product Line | ePDU |
| Product Series | Managed |
| Product Model | EMA115-10 |
| Product Name | ePDU Managed EMA115-10 24-Outlets PDU |
| Product Type | PDU |
| Technical Information | |
| PDU Type | Switched |
| Plug/Connector Type | NEMA L6-20P,IEC 60320 C20 |
| Plug/Connector Detail | 1 x NEMA L6-20P,1 x IEC 60320 C20 |
| Receptacle Type | IEC 60320 C19,IEC 60320 C13 |
| Receptacle Detail | 3 x IEC 60320 C19,21 x IEC 60320 C13 |
| Power Description | |
| Input Voltage | 120 V AC,230 V AC |
| Input Voltage Range | 120 V AC - 230 V AC |
| Output Voltage | 120 V AC,230 V AC |
| Power Rating (Watt) | 3.84 kW |
| Input Current | 16 A |
| Interfaces/Ports | |
| Network (RJ-45) | Yes |
| Physical Characteristics | |
| Mounting Orientation | Vertical |
| Mount Type | Rack-mountable |
| Rack Height | 36U |
| Height | 63.10" (1602.74 mm) |
| Width | 2.05" (52.07 mm) |
| Depth | 2.09" (53.09 mm) |
| Miscellaneous | |
| Package Contents | ePDU Managed EMA115-10 24-Outlets PDU ePDU G3 Installation Spare Pack ePDU G3 Network Spare Part Pack |
| Country of Origin | China |
| Warranty | |
| Limited Warranty | 3 Year |
User Manual
FAQ
What is the power capacity of this Eaton ePDU?
The Eaton EMA115-10 delivers 3.84 kW of power capacity with a 16A input current. This capacity supports high-density server racks and power-hungry equipment while maintaining stable operation across both 120V and 230V AC input voltages.
How many outlets does this PDU have and what types?
This PDU features 24 total outlets: 21 IEC 60320 C13 receptacles and 3 IEC 60320 C19 receptacles. The C13 outlets are standard for most IT equipment, while the C19 outlets handle higher-power devices like servers and storage arrays.
What does 'switched management' mean for this PDU?
Switched management allows remote monitoring and control of individual outlets via the network interface. Administrators can view current draw per outlet, remotely power cycle equipment, implement load balancing, and set up power sequencing schedules without physical access to the rack.
What rack mounting options are available?
This PDU is designed for vertical rack mounting with a 36U height profile. It mounts directly into standard 19-inch server racks using included hardware, occupying the full height of the rack for optimal power distribution along the entire equipment column.
What input voltage does this PDU support?
The PDU accepts both 120V and 230V AC input with a range of 120-230V AC. It uses a NEMA L6-20P or IEC C20 input plug in a single-phase configuration, making it compatible with common North American and international power infrastructures.
What is included in the package with this PDU?
The package includes the ePDU Managed EMA115-10 24-Outlets PDU unit, an ePDU G3 Installation Spare Pack with mounting hardware, and an ePDU G3 Network Spare Part Pack for maintenance. All components necessary for installation and ongoing operation are provided.
What power capacity is listed for this UPS?
The listed power specification is 3.84 kW, which helps position the unit for the right load level and installation role.
What runtime or backup profile is mentioned?
Eaton ePDU G3 Managed 36U-A IN: L6-20P/C20 16A 1P OUT: 21xC13:3xC19 - Switched - NEMA L6-20P, IEC 60320 C20 - 3 x IEC 60320 C19, 21 x (EMA115-10) should be evaluated around its backup-runtime profile, power capacity, and outlet layout so buyers can judge whether it fits workstation, networking, or edge-protection needs.