Sidebar Sidebar Sidebar
sale
Sold out

Shipping included*

Eaton EVMAG332X G4 Managed PDU - 42 Outlets - 24x C13 - 18x C39 - 17. 3 kW/kVA - 3-Phase 230/415V AC - 0U Vertical Rack Mount

SKU: EVMAG332X
UPC: 786689795047
(No reviews) Write a Review
MSRP: $4,388.28
$4,388.28
$3,281.99
Save: $1,106.29 (25.21%)
Warranty Information: 3 Year
Condition: New
Width: 5.31 (cm)
Height: 1.23 (cm)
Depth: 5.21 (cm)

Ask for ETA! 🗨️

Logo cards
B2B Pricing

Business volume discounts

IT Experts

Technical guidance

IT Configuration

Preparation & staging

Canada Stock

QC · ON · AB · BC

Product Features

Description

Product Overview

The Eaton G4 EVMAG332X is a managed three-phase power distribution unit engineered for high-density data center and IT equipment deployments. This 42-outlet PDU delivers 17.3 kW/kVA of reliable power distribution with comprehensive monitoring and control capabilities through its integrated SNMP Gigabit network module.

Designed for vertical 0U rack mounting, this unit features a mix of 24 IEC C13 and 18 IEC C39 outlets to accommodate diverse server, networking, and storage power connections. The built-in LCD display provides at-a-glance status information, while three-phase 230/415V AC input support ensures compatibility with modern data center power infrastructure.

This section brings together practical product details such as PDU Type, Phase, Plug/Connector Type, Input Voltage, so buyers can judge configuration, deployment fit, and day-to-day suitability with less guesswork.

Power
17.30 kW
Power Capacity
230 V AC,415 V ACVertical
Power Capacity & Electrical
Power Rating17.30 kVA / 17.30 kW
Input Voltage230 V AC, 415 V AC
Input Current32 A
Outlets & Configuration
Total Outlets42
Receptacle Types24 x IEC 60320 C13, 18 x IEC 60320 C39
Plug Type532P6W
Management & Monitoring
PDU TypeManaged
Management InterfaceSNMP Gigabit Network Module G4
DisplayLCD Display
Physical Installation
Rack Height0U
Mounting OrientationVertical
Mount TypeRack-mountable, Button Mount

Technical Overview

This managed PDU operates on three-phase power with 230V AC and 415V AC input voltage options, delivering output voltages of 415V AC, 240V AC, and 208V AC. The 32A input current capacity supports the full 17.3 kW power rating, making it suitable for demanding IT environments.

Network management is enabled through the integrated G4 SNMP Gigabit module, providing remote monitoring, control, and alerting capabilities. Single pole overload protection safeguards connected equipment, while the 10-foot power cord offers flexible installation options.

This section brings together practical product details such as PDU Type, Phase, Plug/Connector Type, Input Voltage, so buyers can judge configuration, deployment fit, and day-to-day suitability with less guesswork.

A strong technical summary explains how the product's interfaces, hardware profile, and operating characteristics work together in real deployment. Buyers often need this context to confirm compatibility with existing devices, expected performance in daily use, and whether installation will be straightforward for IT staff or end users.

Power Capacity17.3 kW/kVA
Input Current32A
Cord Length10 ft (3.05 m)
Three PhaseManagedSNMPLCD Display

Key Product Advantages

The Eaton G4 EVMAG332X combines high outlet density with enterprise-grade management features, providing data center operators with both power distribution flexibility and operational visibility. The vertical 0U form factor maximizes rack space utilization while maintaining accessibility to all outlets.

High-Density Power Distribution

With 42 total outlets (24 C13 + 18 C39), this PDU supports extensive equipment deployments in a single rack unit, reducing cable clutter and simplifying power management.

  • 24 IEC 60320 C13 outlets
  • 18 IEC 60320 C39 outlets
  • Mixed outlet configuration

Enterprise Management Capabilities

The integrated SNMP Gigabit network module enables remote monitoring, power cycling, and alerting, allowing IT staff to manage power infrastructure alongside other network devices.

  • SNMP protocol support
  • Gigabit network interface
  • Remote management capabilities

Data Center Optimized Design

Three-phase power support, vertical mounting orientation, and 0U rack height make this PDU ideal for modern data center environments where space and power efficiency are critical.

  • Three-phase operation
  • Vertical 0U mounting
  • Data center focused

Deployment / Use Cases

This managed PDU is specifically designed for data center environments where reliable, monitored power distribution is essential for server racks, networking equipment, and storage arrays. The three-phase power support makes it suitable for larger installations where single-phase PDUs would be insufficient.

IT equipment rooms, colocation facilities, and enterprise server racks benefit from the outlet density and management capabilities. The vertical mounting orientation keeps outlets accessible while minimizing the rack footprint, and the mixed outlet types accommodate both standard server power cords and higher-amperage equipment connections.

Server Rack Power Distribution

Ideal for high-density server deployments where multiple devices require reliable, monitored power in a single rack enclosure.

Network Equipment Closets

Provides managed power for switches, routers, and other networking gear with remote monitoring capabilities for distributed IT environments.

Physical Profile

The Eaton G4 EVMAG332X features a vertical form factor designed for 0U rack mounting with dimensions of 68.10" height × 2.09" width × 2.05" depth (1729.74 × 53.09 × 52.07 mm). The black finish matches standard rack equipment aesthetics, while the 19.40 lb (8.8 kg) weight ensures stable installation. Button mount hardware facilitates secure rack attachment, and the vertical orientation optimizes outlet accessibility in crowded rack environments.

Color
Black
Dimensions
Width
2.09" (53.09 mm)
Depth
2.05" (52.07 mm)
Height
0U
Weight
19.40 lb (8799.69 g)
Length
10 ft (3.05 m)
Dimensions68.10" H × 2.09" W × 2.05" D
Weight19.40 lb (8.8 kg)

What's in the Box

The package includes the G4 EVMAG332X 42-outlets PDU unit along with mounting buttons for secure rack installation.

Package contents include G4 EVMAG332X 42-Outlets PDU Mounting Buttons, G4 EVMAG332X 42-Outlets PDU. These included items support setup, installation, and immediate deployment without needing to source the core bundled accessories separately.

G4 EVMAG332X 42-Outlets PDU Mounting Buttons
G4 EVMAG332X 42-Outlets PDU
[custom-highlights]

Highlights

  • Managed three-phase PDU with 42 total outlets (24 C13 + 18 C39)
  • 17.3 kW/kVA power capacity with 32A input current rating
  • SNMP Gigabit network module for remote monitoring and control
  • Vertical 0U rack-mountable form factor with button mount hardware
  • Three-phase 230/415V AC input with multiple output voltage options
  • LCD display for local status monitoring and configuration
  • 10-foot power cord for flexible installation
  • Single pole overload protection for equipment safety
  • Black finish matching standard rack equipment aesthetics
  • 3-year limited warranty with TAA compliance
[/custom-highlights][custom-specifications]

Specifications

Specifications
ManufacturerEaton Corporation
Manufacturer Part NumberEVMAG332X
Brand NameEaton
Product SeriesG4
Product ModelEVMAG332X
Product NameG4 EVMAG332X 42-Outlets PDU
Product TypePDU
Technical Information
PDU TypeManaged
PhaseThree Phase
Plug/Connector Type532P6W
Receptacle TypeIEC 60320 C13,IEC 60320 C39
Receptacle Detail24 x IEC 60320 C13,18 x IEC 60320 C39
Protection TypeSingle Pole,Overload Protection
FeaturesLCD Display
Load Capacity (VA)17.30 kW
Load Capacity (Watt)17.30 kW
Power Description
Input Voltage230 V AC,415 V AC
Output Voltage415 V AC,240 V AC,208 V AC
Power Rating (VA)17.30 kVA
Power Rating (Watt)17.30 kW
Input Current32 A
Management
ManagementSNMP Gigabit Network Module G4
Interfaces/Ports
Network (RJ-45)Yes
Physical Characteristics
Color FamilyBlack
Product ColorBlack
Mounting OrientationVertical
Mount TypeRack-mountable,Button Mount
Form FactorVertical
Rack Height0U
Cord Length10 ft (3.05 m)
Height68.10" (1729.74 mm)
Width2.09" (53.09 mm)
Depth2.05" (52.07 mm)
Weight (Approximate)19.40 lb (8799.69 g)
Environmental Conditions
Minimum Operating Temperature32°F (0°C)
Maximum Operating Temperature140°F (60°C)
Minimum Storage Temperature-13°F (-25°C)
Maximum Storage Temperature149°F (65°C)
Miscellaneous
Package ContentsG4 EVMAG332X 42-Outlets PDU Mounting Buttons
Application/UsageData Center,IT Equipment
Country of OriginMorocco
TAA CompliantYes
Environmental ComplianceRestriction of Hazardous Substances (RoHS)
Warranty
Limited Warranty3 Year
[/custom-specifications][custom-user-manual]

User Manual

This section contains official documentation provided by the manufacturer, including product manuals, brochures, and supplementary materials.
[/custom-user-manual][custom-faq]

FAQ

What types of outlets does this Eaton PDU provide?

The Eaton G4 EVMAG332X PDU provides 42 total outlets with a mixed configuration: 24 IEC 60320 C13 outlets and 18 IEC 60320 C39 outlets. This combination accommodates both standard server power cords (C13) and higher-amperage equipment connections (C39), offering flexibility for diverse IT equipment deployments in data center environments.

What is the power capacity of this managed PDU?

This managed PDU has a power rating of 17.30 kVA (17.30 kW), making it suitable for high-density server racks and networking equipment. The 32A input current supports this capacity across three-phase 230/415V AC input, providing robust power distribution for demanding IT environments while maintaining efficiency and reliability.

How is this PDU managed and monitored?

The Eaton G4 EVMAG332X includes an integrated SNMP Gigabit Network Module G4 for comprehensive management. This enables remote monitoring, power control, and alerting through standard network management protocols. Additionally, a local LCD display provides at-a-glance status information, giving administrators both local and remote visibility into power distribution and utilization.

What rack mounting options are available?

This PDU is designed for vertical 0U rack mounting using the included button mount hardware. The vertical orientation optimizes outlet accessibility while minimizing the rack footprint, and the 0U height means it doesn't consume valuable rack unit space. The mounting buttons ensure secure installation in standard 19-inch racks commonly used in data centers.

What input voltages does this three-phase PDU support?

The Eaton G4 EVMAG332X supports three-phase input voltages of 230 V AC and 415 V AC, making it compatible with various data center power infrastructures. It delivers output voltages of 415 V AC, 240 V AC, and 208 V AC to accommodate different equipment requirements, providing flexibility in mixed-environment deployments.

What protection features are included?

This managed PDU includes single pole overload protection to safeguard connected equipment from power anomalies. The protection system monitors power distribution and can help prevent damage to sensitive IT equipment. Combined with the managed capabilities, this provides both proactive monitoring and reactive protection for critical infrastructure.

What power capacity is listed for this UPS?

The listed power specification is 17.30 kW, which helps position the unit for the right load level and installation role.

What voltage details are listed?

The listed power specification is 230 V AC,415 V AC, which helps position the unit for the right load level and installation role.

[/custom-faq]
Volume Discounts
Qty Price Available
Match Price Request

Found a lower price? Send us the link and we will do our best to match or beat it.

Request received. We will reply within 24 hours.
Fleet Network
Wholesale & B2B
Partner with Us

Looking to buy in bulk? We offer competitive pricing, dedicated support, and custom solutions for businesses of all sizes.

Volume Discounts

Tiered pricing structure designed to maximize your margins as you grow.

Dedicated Account Manager

Direct access to a specialist who understands your business needs.

Fast & Reliable Shipping

Priority processing and discounted shipping rates for bulk orders.

Request a Quote
Thank you!
Your request has been sent successfully.
Eaton EVMAG332X G4 Managed PDU - 42 Outlets - 24x C13 - 18x C39 - 17. 3 kW/kVA - 3-Phase 230/415V AC - 0U Vertical Rack Mount
MSRP: $4,388.28
$4,388.28
$3,281.99
Save: $1,106.29 (25.21%)
Out of stock