Product Features
Technical Overview
This double conversion online UPS provides full isolation from raw utility power, continuously regenerating clean AC output regardless of input quality. It accepts 120V AC input with a wide 0-160V AC range and delivers regulated output at 120V, 110V, or 127V AC, supporting both 50Hz and 60Hz frequencies. The true sine wave output is essential for powering active PFC power supplies found in modern servers and networking gear without risk of shutdown or damage.
The unit incorporates a built-in bypass switch and cold start function, allowing manual operation and startup without utility power when required. Battery runtime is rated at 3 minutes under full 2700W load and extends to 10 minutes at half load, providing sufficient time for orderly system shutdown or generator transfer.
Key Product Advantages
The Encompass RTXL series combines high power density with deployment versatility, making it an ideal choice for IT closets, server rooms, and edge computing locations. Its 2U rack height maximizes power capacity within minimal vertical space, while the tower and compact form options accommodate environments without rack infrastructure.
Critical Load Protection
With 3 kVA capacity and true sine wave output, this UPS safeguards sensitive electronics from harmonics, voltage fluctuations, and complete blackouts, preventing data corruption and hardware failure.
- Pure power conditioning
- Active PFC compatibility
- Voltage regulation
Operational Resilience
Features like hot-swappable batteries, a built-in bypass switch, and remote management capabilities minimize downtime and simplify maintenance during extended outages or battery replacement.
- No downtime battery swaps
- Remote monitoring
- Manual bypass option
Installation Flexibility
The rack/tower/compact design adapts to diverse physical environments, from standardized data centers to distributed network racks and equipment rooms.
- 2U rack mount
- Tower conversion
- Compact footprint
Deployment / Use Cases
This UPS is designed for environments where power quality and continuity are non-negotiable. Its 3000VA capacity and robust outlet configuration—featuring six NEMA 5-15/20R and one NEMA L5-30R receptacle—support a mix of server, networking, and peripheral devices.
In medical and healthcare settings, it ensures life-critical monitoring and diagnostic equipment remain operational through brief utility interruptions. For VoIP phone systems and security installations, it maintains communication and surveillance uptime. Government and edge computing deployments benefit from its TAA compliance and ability to operate in varied environmental conditions, with a specified range from 32°F to 104°F and 10-90% humidity.
This section brings together practical product details such as Plug/Connector Type, Receptacle Type, Receptacle Detail, Load Capacity (VA), so buyers can judge configuration, deployment fit, and day-to-day suitability with less guesswork.
Physical Profile
The unit measures 3.50" (H) x 18.90" (W) x 23.70" (D), occupying two rack units (2U) of vertical space in a standard 19-inch rack. Its weight of approximately 65.7 pounds reflects a robust internal construction with ample battery capacity. The compact tower form is practical for standalone use, while integrated mounting hardware facilitates secure rack installation. The design supports operation at elevations up to 9842 feet, accommodating high-altitude deployments.
- Width
- 18.90" (480.06 mm)
- Height
- 3.50" (88.90 mm)
- Weight
- 65.70 lb (29801.02 g)
- Length
- 10 ft (3.05 m)
Highlights
- 3000VA / 2700W double conversion online UPS for maximum power protection
- 2U rack-mountable design with tower and compact deployment options
- True sine wave output ensures compatibility with sensitive server and network equipment
- 3-minute runtime at full load, 10 minutes at half load for orderly shutdown
- Hot-swappable, maintenance-free lead-acid batteries for easy replacement
- LCD display with network management via RS-232, SNMP, and network card
- Six NEMA 5-15/20R and one NEMA L5-30R outlets for versatile device connectivity
- ENERGY STAR 2.0 certified and TAA compliant for government and commercial use
- Wide input voltage range (0-160V AC) and 50/60Hz output frequency support
- Full three-year warranty including battery coverage
Specifications
| Specifications | |
|---|---|
| Manufacturer | Para Systems, Inc |
| Manufacturer Part Number | EC3000RTXL2UNC |
| Brand Name | Minuteman |
| Product Line | Encompass |
| Product Series | RTXL |
| Product Model | EC3000RTXL2UNC |
| Product Name | Encompass RTXL EC3000RTXL2UNC 3000VA Rack/Tower/Compact UPS |
| Product Type | Double Conversion Online UPS |
| Technical Information | |
| Plug/Connector Type | NEMA L5-30P |
| Receptacle Type | NEMA 5-15/20R,NEMA L5-30R |
| Receptacle Detail | 6 x NEMA 5-15/20R,1 x NEMA L5-30R |
| Cord Length | 10 ft (3.05 m) |
| Application/Usage | Medical,Network,Server,VoIP Phone System,IP Phone,Security,Edge Computing,Government,Security System,Audio/Video Equipment,Equipment,Hospital |
| Features | Cold Start Function,Built-in Bypass Switch |
| Power Description | |
| Load Capacity (VA) | 3 kVA |
| Load Capacity (Watt) | 2.70 kW |
| Input Voltage | 120 V AC |
| Input Voltage Range | 0 V AC - 160 V AC |
| Output Voltage | 120 V AC,110 V AC,127 V AC |
| Input Frequency | 50 Hz,60 Hz |
| Output Frequency | 50 Hz,60 Hz |
| Waveform Type | True Sine Wave |
| Output Power Factor | 0.9 |
| Display & Graphics | |
| Display | LCD |
| Management | |
| Network Management | RS-232,SNMP,Network Card |
| Interfaces/Ports | |
| Serial Port | Yes |
| USB | Yes |
| EPO Port | Yes |
| Battery Information | |
| Battery Characteristics | Sealed, Non-spillable, Maintenance-free, Valve-regulated |
| Battery Chemistry | Lead Acid |
| Backup/Run Time (Full Load) | 3 Minute |
| Backup/Run Time (Half Load) | 10 Minute |
| Hot Swappable | Yes |
| Replaceable Battery | Yes |
| Environmental Conditions | |
| Maximum Operating Elevation | 9842.52 ft (3000000 mm) |
| Operating Humidity | 10% - 90% |
| Minimum Operating Temperature | 32°F (0°C) |
| Maximum Operating Temperature | 104°F (40°C) |
| Physical Characteristics | |
| Height | 3.50" (88.90 mm) |
| Width | 18.90" (480.06 mm) |
| Length | 23.70" (601.98 mm) |
| Rack Height | 2U |
| Form Factor | Rack/Tower/Compact |
| Weight (Approximate) | 65.70 lb (29801.02 g) |
| Miscellaneous | |
| Energy Star | Yes |
| TAA Compliant | Yes |
| Energy Efficiency Certification | ENERGY STAR 2.0 |
| Environmental Compliance | Restriction of Hazardous Substances (RoHS) 2,Restriction of Hazardous Substances (RoHS) |
| Warranty | |
| Limited Warranty | 3 Year |
| Additional Warranty Information | Full 3-year warranty which includes batteries. |
FAQ
What is the power capacity of this Minuteman UPS?
This Minuteman Encompass RTXL UPS provides 3000VA (3 kVA) of apparent power and 2700 watts of real power capacity. It uses double conversion online topology to deliver clean, regulated power, making it suitable for protecting critical servers, network gear, and medical equipment from power disturbances.
How long will this UPS run on battery during a power outage?
At its maximum rated load of 2700 watts, the battery runtime is 3 minutes. When supporting a reduced load of approximately 1350 watts (half load), the runtime extends to 10 minutes. This provides sufficient time for connected systems to perform a graceful shutdown or for backup generators to engage.
What types of power outlets does this UPS have?
The unit includes six NEMA 5-15/20R receptacles (standard 15A/20A 125V) and one NEMA L5-30R receptacle (30A 125V locking). This combination allows you to power a mix of servers, switches, and higher-draw equipment directly from the UPS without additional PDUs in many configurations.
Can this UPS be mounted in a standard server rack?
Yes, it is designed for 2U rack mounting in a standard 19-inch rack. The form factor is also described as rack/tower/compact, meaning it can be used as a standalone tower or in compact placements if rack mounting is not required, offering deployment flexibility.
What management and monitoring options are available?
Local management is provided via an LCD display on the unit. For remote monitoring and control, it includes an RS-232 serial port, support for SNMP, and compatibility with an optional network management card. A USB port and EPO (Emergency Power Off) port are also present for additional integration and safety functions.
What is the warranty coverage for this UPS?
Minuteman provides a full three-year warranty that includes the batteries. This comprehensive coverage protects against defects in materials and workmanship for the entire unit, including the sealed, maintenance-free lead-acid battery pack, for three years from the date of purchase.
What power capacity is listed for this UPS?
The listed power specification is 3 kVA, which helps position the unit for the right load level and installation role.
What voltage details are listed?