Sidebar Sidebar Sidebar
sale
Sold out

Shipping included*

Minuteman ED6KTF Endeavor 6000VA/6kW Tower UPS - Double Conversion Online - True Sine Wave - Hardwired - 5 Min Full Load Runtime

SKU: ED6KTF
UPC: 784755160058
(No reviews) Write a Review
MSRP: $7,213.69
$7,213.69
$4,208.99
Save: $3,004.70 (41.65%)
Warranty Information: 2 Year
Condition: New
Width: 24.89 (cm)
Height: 82.55 (cm)
Depth: 1.23 (cm)

Ask for ETA! 🗨️

Logo cards
B2B Pricing

Business volume discounts

IT Experts

Technical guidance

IT Configuration

Preparation & staging

Canada Stock

QC · ON · AB · BC

Product Features

Description

Product Overview

The Minuteman Endeavor ED6KTF is a 6000VA/6kW double conversion online UPS designed for demanding environments where clean, reliable power is non-negotiable. This tower-form factor unit delivers true online protection, continuously converting incoming AC power to DC and back to a clean AC output, isolating connected equipment from all common power problems including surges, sags, and frequency variations.

Engineered for mission-critical applications, it features a robust 6 kVA capacity capable of supporting high-end systems, network infrastructure, and sensitive electronics. The unit provides a 5-minute runtime at full load, offering sufficient time for graceful system shutdowns or transfer to generator power during extended outages. Its hardwired connection design ensures a secure, permanent installation for dedicated power circuits.

This section brings together practical product details such as Plug/Connector Type, Receptacle Type, Phase, Load Capacity (VA), so buyers can judge configuration, deployment fit, and day-to-day suitability with less guesswork.

Power
6 kVA
Power Capacity
120 V AC,230 V AC
Power Capacity & Runtime
Load Capacity (VA/Watt)6 kVA / 6 kW
Backup Runtime (Full Load)5 Minute
Backup Runtime (Half Load)14 Minute
Electrical Specifications
Input Voltage120 V AC, 230 V AC
Output Voltage240 V AC, 208 V AC, 230 V AC, 120 V AC
Waveform TypeTrue Sine Wave
Battery & Physical
Number of Batteries20
Battery ChemistryLead Acid
Form FactorTower
Warranty & Compliance
Limited Warranty2 Year
Environmental ComplianceRoHS 2

Technical Overview

This double conversion online UPS operates with a true sine wave output, ensuring compatibility with sensitive server power supplies, networking gear, and medical equipment that require pure AC power. The electrical design accepts a wide input voltage range from 110V AC to 300V AC, with specific nominal inputs at 120V and 230V AC, and delivers stable output at 120V, 208V, 230V, or 240V AC at 60 Hz.

The power system is built around 20 sealed, valve-regulated lead-acid batteries that are maintenance-free and non-spillable. A front-panel LCD display provides clear status indicators for AC input, battery condition, and any UPS faults, enabling quick operational assessment. The unit includes an 880-joule surge energy rating for additional protection against voltage spikes.

This section brings together practical product details such as Plug/Connector Type, Receptacle Type, Phase, Load Capacity (VA), so buyers can judge configuration, deployment fit, and day-to-day suitability with less guesswork.

Input Frequency60 Hz
Output Frequency60 Hz
Surge Protection880 J
Single PhaseHardwiredLCD Display

Key Product Advantages

The Endeavor ED6KTF distinguishes itself with industrial-grade double conversion technology that provides the highest level of power conditioning available. This makes it ideal for protecting sensitive loads where even minor power fluctuations can cause data corruption, hardware damage, or system downtime.

True Online Isolation

Continuous double conversion completely isolates connected equipment from raw utility power, eliminating transfer switches and providing zero transfer time during outages or fluctuations.

  • Clean output regardless of input quality
  • No break in power during grid failure

High-Capacity Design

With 6 kVA/6 kW of power capacity, this UPS can support multiple servers, storage arrays, or network racks simultaneously, making it suitable for small data center closets or server rooms.

  • Supports high-density equipment loads
  • Scalable for growing power requirements

Industrial Durability

Built for 24/7 operation with a maximum operating temperature of 104°F (40°C) and robust battery construction designed for reliable performance in controlled environments.

  • VRLA battery technology
  • Wide operating temperature range

Deployment / Use Cases

This UPS is engineered for environments where power quality directly impacts operational continuity and data integrity. Its capacity and runtime make it suitable for protecting consolidated infrastructure where multiple critical systems share a power circuit.

Primary deployment scenarios include small to medium server rooms, network closets supporting VoIP systems and distributed antenna systems (DAS), security and surveillance command centers, and educational or medical facilities with sensitive diagnostic equipment. The hardwired installation makes it ideal for permanent integration into electrical panels serving dedicated equipment circuits.

Data Center & Server Room

Provides clean power to rack-mounted servers, network switches, and storage systems, with sufficient runtime for orderly shutdown or generator start-up sequences.

Critical Infrastructure Support

Protects VoIP phone systems, security system controllers, and distributed antenna systems that must remain operational during power disturbances to maintain communication and monitoring capabilities.

Data CenterNetwork ClosetSecurity SystemVoIPMission Critical

Physical Profile

The ED6KTF features a substantial tower design with dimensions of 32.50" H × 9.80" W × 22.10" D (825.5 × 248.92 × 561.34 mm) and a weight of approximately 237 lb (107.5 kg). Its black finish suits professional IT environments, and the substantial weight requires proper placement consideration—typically on reinforced flooring or in dedicated equipment rooms. The form factor is designed for standalone placement rather than rack mounting, with accessibility to the front LCD panel and connection points.

Color
Black
Dimensions
Width
9.80" (248.92 mm)
Height
32.50" (825.50 mm)
Weight
237 lb (107501.39 g)
Length
22.10" (561.34 mm)
[custom-highlights]

Highlights

  • 6000VA/6000W double conversion online UPS for maximum power protection
  • True sine wave output compatible with sensitive server and network equipment
  • 5-minute runtime at full load (14 minutes at half load) for graceful shutdowns
  • Hardwired input and output connections for permanent, secure installation
  • Accepts 120V or 230V AC input, outputs 120V/208V/230V/240V AC
  • Front-panel LCD display with AC input, battery, and fault status indicators
  • 20 sealed, maintenance-free lead-acid batteries (VRLA technology)
  • 2-year limited warranty and RoHS 2 environmental compliance
  • Industrial-grade construction with 104°F (40°C) maximum operating temperature
  • Ideal for data centers, network closets, security systems, and VoIP infrastructure
[/custom-highlights][custom-specifications]

Specifications

Specifications
ManufacturerPara Systems, Inc
Manufacturer Part NumberED6KTF
Brand NameMinuteman
Product LineEndeavor
Product ModelED6KTF
Product NameEndeavor ED6KTF 6000VA Tower UPS
Product TypeDouble Conversion Online UPS
Technical Information
Plug/Connector TypeHardwired
Receptacle TypeHardwired
PhaseSingle Phase
Application/UsageData Center,Network Closet,Security System,High-end System,Education,Network,Distributed Antenna System (DAS),Telephone,VoIP,Mission Critical Equipment
Power Description
Load Capacity (VA)6 kVA
Load Capacity (Watt)6 kW
Input Voltage120 V AC,230 V AC
Input Voltage Range208 V AC - 240 V AC,0 V AC - 300 V AC,110 V AC - 300 V AC
Output Voltage240 V AC,208 V AC,230 V AC,120 V AC
Input Frequency60 Hz
Output Frequency60 Hz
Waveform TypeTrue Sine Wave
Surge Energy Rating880 J
Display & Graphics
DisplayLCD
Controls/Indicators
Status IndicatorsLCD Display: AC Input Status Battery Status UPS Fault Indication
Battery Information
Number of Batteries20
Battery CharacteristicsSealed, Non-spillable, Maintenance-free, Valve-regulated
Battery ChemistryLead Acid
Backup/Run Time (Full Load)5 Minute
Backup/Run Time (Half Load)14 Minute
Environmental Conditions
Storage Temperature5°F (-15°C) - 140°F (60°C)
Maximum Operating Temperature104°F (40°C)
Physical Characteristics
Product ColorBlack
Height32.50" (825.50 mm)
Width9.80" (248.92 mm)
Length22.10" (561.34 mm)
Weight (Approximate)237 lb (107501.39 g)
Miscellaneous
Environmentally FriendlyYes
Environmental ComplianceRestriction of Hazardous Substances (RoHS) 2
Warranty
Limited Warranty2 Year
[/custom-specifications][custom-user-manual]

User Manual

This section contains official documentation provided by the manufacturer, including product manuals, brochures, and supplementary materials.
[/custom-user-manual][custom-faq]

FAQ

What type of UPS topology does the Minuteman ED6KTF use?

The Minuteman ED6KTF utilizes double conversion online topology, which is the highest level of UPS protection available. This technology continuously converts incoming AC power to DC and then back to clean AC output, completely isolating connected equipment from utility power issues like sags, surges, harmonics, and frequency variations. There is zero transfer time during outages since the load always runs on inverter power.

What is the power capacity and runtime of this UPS?

This UPS has a 6000VA/6000W power capacity. At full load (6 kW), it provides 5 minutes of battery runtime, which allows sufficient time for orderly system shutdowns or transfer to a backup generator. At half load (3 kW), the runtime extends to approximately 14 minutes. These runtimes are designed to bridge short power interruptions or provide critical minutes for controlled power management.

What input and output voltages does it support?

The ED6KTF accepts nominal input voltages of 120V AC and 230V AC, with a wide input range from 110V AC to 300V AC for flexibility. It outputs stable power at 120V AC, 208V AC, 230V AC, or 240V AC, all at 60 Hz. This multi-voltage capability makes it suitable for various electrical environments and equipment requirements.

Is the output waveform suitable for sensitive electronics?

Yes, this UPS produces a true sine wave output, which is essential for powering sensitive server power supplies, medical equipment, and advanced networking gear that require clean, utility-grade AC power. True sine wave prevents compatibility issues, overheating, and potential damage that can occur with simulated or stepped approximations.

How is the UPS connected to power and equipment?

The ED6KTF features hardwired connections for both input and output, meaning it is designed for permanent installation by a qualified electrician. It connects directly to your electrical circuit rather than using standard plugs, providing a secure, dedicated power path. This is typical for high-capacity UPS units installed in server rooms or data centers.

What type of batteries does it use and how many?

This UPS contains 20 sealed, valve-regulated lead-acid (VRLA) batteries that are maintenance-free and non-spillable. These industrial-grade batteries provide the energy storage for runtime during outages. The VRLA design is safe for indoor use, requires no watering, and is housed within the unit's tower enclosure.

What power capacity is listed for this UPS?

The listed power specification is 6 kVA, which helps position the unit for the right load level and installation role.

What voltage details are listed?

The listed power specification is 120 V AC,230 V AC, which helps position the unit for the right load level and installation role.

[/custom-faq]
Volume Discounts
Qty Price Available
Match Price Request

Found a lower price? Send us the link and we will do our best to match or beat it.

Request received. We will reply within 24 hours.
Fleet Network
Wholesale & B2B
Partner with Us

Looking to buy in bulk? We offer competitive pricing, dedicated support, and custom solutions for businesses of all sizes.

Volume Discounts

Tiered pricing structure designed to maximize your margins as you grow.

Dedicated Account Manager

Direct access to a specialist who understands your business needs.

Fast & Reliable Shipping

Priority processing and discounted shipping rates for bulk orders.

Request a Quote
Thank you!
Your request has been sent successfully.
Minuteman ED6KTF Endeavor 6000VA/6kW Tower UPS - Double Conversion Online - True Sine Wave - Hardwired - 5 Min Full Load Runtime
MSRP: $7,213.69
$7,213.69
$4,208.99
Save: $3,004.70 (41.65%)
Out of stock