Panduit P24E32G G6 24-Outlet PDU - Monitored & Switched - 17. 3 kW - 230V AC Input - 12x C13 & 12x C19 - Rack-Mountable
Business volume discounts
Technical guidance
Preparation & staging
QC · ON · AB · BC
Product Features
Technical Overview
This PDU operates on 230V AC input voltage with 60A input current, delivering 208V AC output to connected equipment. The unit features 24 total outlets configured as 12 IEC 60320 C13 receptacles and 12 IEC 60320 C19 receptacles, accommodating both standard and high-power server connections. Network connectivity via RJ-45 enables remote management and monitoring capabilities.
The onboard display provides at-a-glance status information, while the switched functionality allows individual outlet control for power cycling and load management. Environmental specifications include operation from 50°F to 140°F (10°C to 60°C) and storage from 24.8°F to 284°F (-4°C to 140°C), ensuring reliable performance across typical data center conditions.
This section brings together practical product details such as PDU Type, Phase, Plug/Connector Type, Input Voltage, so buyers can judge configuration, deployment fit, and day-to-day suitability with less guesswork.
Key Product Advantages
The Panduit G6 PDU combines monitoring and switching capabilities in a single rack-optimized unit, providing data center managers with both visibility and control over power distribution. Remote management functionality reduces the need for physical access to equipment, while load monitoring helps prevent circuit overloads and optimize power utilization.
Remote Power Management
Individually control each outlet remotely to reboot equipment or manage power sequencing without physical access to the rack.
- Outlet-level switching
- Network-accessible controls
- Reduced downtime
Real-Time Monitoring
Monitor current draw, power consumption, and environmental conditions through the network interface and onboard display.
- Load monitoring
- Visual status indicators
- Proactive capacity planning
High-Density Configuration
24-outlet design with mixed C13 and C19 receptacles supports diverse equipment types in space-constrained rack environments.
- Mixed outlet types
- Vertical mounting
- Optimized rack space
Deployment / Use Cases
This PDU is specifically designed for data center environments where reliable power distribution and remote management are critical. The 17.3 kW capacity and three-phase power support high-density server racks, network equipment cabinets, and storage arrays in enterprise and colocation facilities.
The switched functionality makes it ideal for environments requiring remote rebooting of equipment, while the monitoring capabilities provide valuable data for capacity planning and power usage effectiveness (PUE) optimization. The vertical mounting orientation and compact 2-inch width maximize usable space in standard 19-inch server racks.
Enterprise Data Centers
Deploy in server racks supporting virtualization hosts, storage systems, and network equipment where remote power management reduces operational overhead.
Colocation Facilities
Provide customers with individually controllable power outlets and monitoring capabilities while maintaining secure physical separation between client equipment.
Physical Profile
The PDU features a vertical rack-mountable design with dimensions of 69 inches in height, 2 inches in width, and 2.10 inches in depth (1752.60 mm x 50.80 mm x 53.34 mm). This slim profile maximizes usable space within standard server racks while providing full front-to-back accessibility. The unit includes a 10-foot (3.05 m) power cord with IEC 60309 3P+E 9H 60A connector rated IP44 for dust and water protection.
- Width
- 2" (50.80 mm)
- Depth
- 2.10" (53.34 mm)
- Height
- 69" (1752.60 mm)
- Length
- 10 ft (3.05 m)
What's in the Box
The package includes the complete PDU unit with all necessary mounting hardware for installation in standard server racks.
Package contents include G6 24-Outlets PDU Mounting Hardware, G6 24-Outlets PDU. These included items support setup, installation, and immediate deployment without needing to source the core bundled accessories separately.
Highlights
- Monitored and switched PDU with remote management capabilities
- 17.3 kW power rating supports high-density equipment deployments
- 24 total outlets: 12 C13 and 12 C19 receptacles
- Three-phase power with 230V AC input and 208V AC output
- Vertical rack-mountable design with 69-inch height
- Onboard display for at-a-glance status monitoring
- Network connectivity via RJ-45 for remote access
- IP44-rated IEC 60309 plug connector
- 10-foot power cord included
- 3-year limited warranty
Specifications
| Specifications | |
|---|---|
| Manufacturer | PANDUIT CORP |
| Manufacturer Part Number | P24E32G |
| Brand Name | Panduit |
| Product Series | G6 |
| Product Name | G6 24-Outlets PDU |
| Packaged Quantity | 1 |
| Product Type | PDU |
| Technical Information | |
| PDU Type | Monitored,Switched |
| Phase | Three Phase |
| Plug/Connector Type | IEC 60309 3P+E 9H 60A (IP44) |
| Receptacle Type | IEC 60320 C13,IEC 60320 C19 |
| Receptacle Detail | 12 x IEC 60320 C13,12 x IEC 60320 C19 |
| Features | Onboard Display |
| Load Capacity (Watt) | 17.30 kW |
| Power Description | |
| Input Voltage | 230 V AC |
| Output Voltage | 208 V AC |
| Power Rating (Watt) | 17.30 kW |
| Input Current | 60 A |
| Input Frequency | 60 Hz |
| Interfaces/Ports | |
| Network (RJ-45) | Yes |
| Physical Characteristics | |
| Product Color | Black |
| Mounting Orientation | Vertical |
| Mount Type | Rack-mountable |
| Cord Length | 10 ft (3.05 m) |
| Height | 69" (1752.60 mm) |
| Width | 2" (50.80 mm) |
| Depth | 2.10" (53.34 mm) |
| Environmental Conditions | |
| Minimum Operating Temperature | 50°F (10°C) |
| Maximum Operating Temperature | 140°F (60°C) |
| Minimum Storage Temperature | 24.8°F (-4°C) |
| Maximum Storage Temperature | 284°F (140°C) |
| Miscellaneous | |
| Package Contents | G6 24-Outlets PDU Mounting Hardware |
| Warranty | |
| Limited Warranty | 3 Year |
User Manual
FAQ
What is the difference between monitored and switched capabilities in this PDU?
This PDU combines both monitoring and switching functions. Monitoring allows you to view real-time power consumption, current draw, and environmental data through the network interface or onboard display. Switching enables remote control of individual outlets, allowing you to power cycle specific equipment without physical access to the rack. This combination provides both visibility into power usage and the ability to manage equipment remotely.
What types of equipment can I connect to the different outlet types?
The PDU includes 12 IEC 60320 C13 outlets and 12 IEC 60320 C19 outlets. C13 outlets are standard for most servers, network equipment, and computing devices. C19 outlets support higher-power equipment such as blade server chassis, high-performance servers, and power distribution units that require more current. The mixed configuration allows you to connect both standard and high-power equipment in the same rack.
How is this PDU mounted in a server rack?
This PDU is designed for vertical mounting in standard 19-inch server racks. With dimensions of 69 inches high by 2 inches wide, it occupies the full height of a standard rack while maintaining a slim profile. The unit includes all necessary mounting hardware for installation. Vertical mounting maximizes usable space within the rack while keeping power distribution organized and accessible.
What input power requirements does this PDU have?
The PDU requires three-phase 230V AC input power with a 60A circuit. The input connector is an IEC 60309 3P+E 9H 60A plug rated IP44 for protection against dust and water ingress. The unit operates at 60 Hz frequency. Ensure your facility's electrical infrastructure can support these requirements before installation.
Can I monitor and control this PDU remotely?
Yes, the PDU includes network connectivity via an RJ-45 port that enables remote monitoring and control. You can access the unit over your network to view power metrics, set alerts, and control individual outlets. The onboard display also provides local status information. Remote management capabilities reduce the need for physical access to equipment for routine power management tasks.
What is the power capacity and how many devices can it support?
The PDU has a 17.3 kW power rating, which represents its maximum load capacity. With 24 total outlets, you can connect multiple devices, but the total power draw of all connected equipment must not exceed 17.3 kW. The actual number of devices depends on their individual power requirements. The monitoring features help you track total load to prevent overloading the circuit.
What power capacity is listed for this UPS?
The listed power specification is 17.30 kW, which helps position the unit for the right load level and installation role.
What voltage details are listed?
The listed power specification is 230 V AC, which helps position the unit for the right load level and installation role.