Panduit P36D31G G6 Monitored Rack PDU - 36 Outlets - 24x C13 - 12x C19 - 17. 3 kW - 230V AC Input - SNMP Network - Vertical Mount
Business volume discounts
Technical guidance
Preparation & staging
QC · ON · AB · BC
Product Features
Technical Overview
This section brings together practical product details such as PDU Type, Phase, Plug/Connector Type, Input Voltage, so buyers can judge configuration, deployment fit, and day-to-day suitability with less guesswork.
A strong technical summary explains how the product's interfaces, hardware profile, and operating characteristics work together in real deployment. Buyers often need this context to confirm compatibility with existing devices, expected performance in daily use, and whether installation will be straightforward for IT staff or end users.
Power Specifications
This PDU accepts 230V AC input and delivers 208V AC output across three phases, with 60Hz input frequency. The 17.3 kW power rating ensures ample capacity for high-density rack deployments.
- Input: 230V AC, 60A
- Output: 208V AC
- Frequency: 60Hz
- Phase: Three Phase
Monitoring & Management
SNMP network management enables remote monitoring of power consumption, outlet status, and environmental conditions. The onboard display provides local visibility without requiring network access.
- SNMP protocol support
- Onboard display for local monitoring
- Network RJ-45 port included
Key Product Advantages
This monitored PDU provides active metering that enables energy optimization and circuit protection. The combination of local display and remote SNMP management gives administrators multiple ways to monitor power usage and prevent overloads before they impact critical equipment.
Proactive Load Management
The monitoring capabilities warn administrators before critical input sources become overloaded, allowing for proactive load balancing and preventing unexpected downtime.
- Real-time power monitoring
- Overload warnings
- Historical usage data
Flexible Outlet Configuration
With 24 C13 and 12 C19 outlets, this PDU supports mixed equipment environments without requiring additional adapters or power strips.
- 24 IEC 60320 C13 outlets
- 12 IEC 60320 C19 outlets
- Mixed equipment support
Deployment / Use Cases
This vertical-mount PDU is designed for standard 19-inch rack installations in data centers, server rooms, and network infrastructure environments. The compact 2.2-inch width maximizes usable rack space while providing full power distribution capabilities.
Ideal for high-density server racks, network equipment cabinets, and storage arrays where multiple devices require reliable, monitored power. The three-phase configuration makes it suitable for larger installations where single-phase PDUs would be insufficient, while the SNMP management integrates with existing network monitoring systems.
Data Center Racks
Deploy in server racks supporting multiple blade servers, storage systems, and networking equipment that require monitored power distribution with high capacity.
Network Equipment Cabinets
Install in telecommunications and network cabinets where switches, routers, and other networking gear need reliable, managed power with outlet-level monitoring.
Physical Profile
The black vertical-mount PDU measures 70 inches in height, 2.20 inches in width, and 3.10 inches in depth, designed specifically for standard rack installation. The 10-foot power cord provides flexibility in positioning relative to power sources, while the vertical orientation optimizes airflow in rack environments.
The physical profile is practical for deployment planning because the dimensions and weight are clearly defined: 70" (1778 mm), 2.20" (55.88 mm), 3.10" (78.74 mm). This helps confirm rack, shelf, desk, or cabinet fit before installation.
- Width
- 2.20" (55.88 mm)
- Depth
- 3.10" (78.74 mm)
- Height
- 70" (1778 mm)
- Length
- 10 ft (3.05 m)
What's in the Box
The package includes the G6 36-Outlets PDU and all necessary mounting hardware for installation in standard 19-inch racks.
Package contents include G6 36-Outlets PDU Mounting Hardware, G6 36-Outlets PDU. These included items support setup, installation, and immediate deployment without needing to source the core bundled accessories separately.
Highlights
- 36 total outlets: 24 IEC 60320 C13 and 12 IEC 60320 C19
- 17.3 kW power rating with 60A input capacity
- SNMP network management for remote monitoring and control
- Onboard display for local power status visibility
- Three-phase configuration for high-power applications
- Vertical rack mounting with compact 2.2-inch width
- 230V AC input with 208V AC output
- 10-foot power cord for installation flexibility
- Black finish for professional appearance
- 3-year limited warranty
Specifications
| Specifications | |
|---|---|
| Manufacturer | PANDUIT CORP |
| Manufacturer Part Number | P36D31G |
| Brand Name | Panduit |
| Product Series | G6 |
| Product Name | G6 36-Outlets PDU |
| Packaged Quantity | 1 |
| Product Type | PDU |
| Technical Information | |
| PDU Type | Monitored |
| Phase | Three Phase |
| Plug/Connector Type | IEC 60309 3P+E 9H 60A (IP44) |
| Receptacle Type | IEC 60320 C13,IEC 60320 C19 |
| Receptacle Detail | 24 x IEC 60320 C13,12 x IEC 60320 C19 |
| Features | Onboard Display |
| Load Capacity (Watt) | 17.30 kW |
| Power Description | |
| Input Voltage | 230 V AC |
| Output Voltage | 208 V AC |
| Power Rating (Watt) | 17.30 kW |
| Input Current | 60 A |
| Input Frequency | 60 Hz |
| Management | |
| Management | SNMP |
| Interfaces/Ports | |
| Network (RJ-45) | Yes |
| Physical Characteristics | |
| Product Color | Black |
| Mounting Orientation | Vertical |
| Mount Type | Rack-mountable |
| Cord Length | 10 ft (3.05 m) |
| Height | 70" (1778 mm) |
| Width | 2.20" (55.88 mm) |
| Depth | 3.10" (78.74 mm) |
| Environmental Conditions | |
| Minimum Operating Temperature | 50°F (10°C) |
| Maximum Operating Temperature | 140°F (60°C) |
| Minimum Storage Temperature | 24.8°F (-4°C) |
| Maximum Storage Temperature | 284°F (140°C) |
| Miscellaneous | |
| Package Contents | G6 36-Outlets PDU Mounting Hardware |
| Warranty | |
| Limited Warranty | 3 Year |
User Manual
FAQ
What is the power capacity of this PDU?
This Panduit G6 PDU has a 17.3 kW power rating with 60A input capacity. It accepts 230V AC input and delivers 208V AC output across three phases, making it suitable for high-density rack deployments requiring substantial power distribution.
How many outlets does this PDU have and what types?
The PDU provides 36 total outlets with a balanced configuration of 24 IEC 60320 C13 outlets and 12 IEC 60320 C19 outlets. This mix supports a wide range of IT equipment from servers and switches to storage arrays and networking gear without requiring additional adapters.
What management capabilities does this PDU offer?
This monitored PDU includes both local and remote management options. It features an onboard display for at-a-glance status monitoring locally and supports SNMP network management for remote monitoring of power consumption, outlet status, and environmental conditions through standard network protocols.
How is this PDU mounted in a rack?
The PDU is designed for vertical mounting in standard 19-inch racks. It measures 70 inches in height, 2.20 inches in width, and 3.10 inches in depth, with a compact profile that maximizes usable rack space. All necessary mounting hardware is included in the package.
What input power does this PDU require?
This three-phase PDU requires 230V AC input at 60Hz frequency with a 60A capacity. It uses an IEC 60309 3P+E 9H 60A connector with IP44 rating for secure electrical connections in data center environments.
What warranty comes with this PDU?
Panduit provides a 3-year limited warranty for this G6 Monitored Rack PDU. The warranty covers manufacturing defects and ensures reliable performance for your power distribution needs in data center and server room applications.
What power capacity is listed for this UPS?
The listed power specification is 17.30 kW, which helps position the unit for the right load level and installation role.
What voltage details are listed?
The listed power specification is 230 V AC, which helps position the unit for the right load level and installation role.