Panduit P42E24G G6 42-Outlet PDU - Monitored & Switched - 17. 3 kW - 230V AC Input - 21x C13/C15 + 21x C13/C15/C19/C21 - Rack-Mountable 40U
Business volume discounts
Technical guidance
Preparation & staging
QC · ON · AB · BC
Product Features
Technical Overview
This PDU operates on a three-phase power system with an IEC 60309 3P+E 9H 60A (IP44) input connector, ensuring robust and secure power delivery. The 17.3 kW power rating and 60 Hz input frequency make it suitable for North American and compatible international power grids. Output is stabilized at 208V AC across all receptacles.
Network management is enabled via an RJ-45 port supporting SNMP, allowing integration into existing data center infrastructure management (DCIM) systems. The onboard display provides real-time metrics such as current load, voltage, and temperature, facilitating quick onsite diagnostics.
This section brings together practical product details such as PDU Type, Phase, Plug/Connector Type, Input Voltage, so buyers can judge configuration, deployment fit, and day-to-day suitability with less guesswork.
A strong technical summary explains how the product's interfaces, hardware profile, and operating characteristics work together in real deployment. Buyers often need this context to confirm compatibility with existing devices, expected performance in daily use, and whether installation will be straightforward for IT staff or end users.
Key Product Advantages
The Panduit G6 PDU combines high outlet density with advanced monitoring and switching capabilities, reducing the risk of overloads and enabling proactive power management. Its vertical mounting saves valuable horizontal rack space while providing full front-access to all outlets.
High-Density Outlet Configuration
With 42 outlets supporting C13, C15, C19, and C21 connectors, this PDU can power a wide array of equipment from 1U servers to larger network switches, minimizing the need for additional power strips.
- 21 x C13/C15 outlets
- 21 x mixed C13/C15/C19/C21 outlets
- Accommodates diverse plug types
Remote Management & Monitoring
SNMP support allows IT staff to monitor power consumption, set alerts for thresholds, and remotely reboot individual outlets, enhancing uptime and operational efficiency.
- SNMP v1/v2c/v3 compatible
- Real-time load monitoring
- Outlet-level control
Deployment / Use Cases
This PDU is designed for deployment in data centers, server rooms, and network closets where reliable, monitored power distribution is critical. Its 17.3 kW capacity and 42 outlets make it ideal for high-density racks containing multiple servers, storage arrays, and networking equipment.
Common applications include powering blade server enclosures, top-of-rack switches, and modular storage systems in enterprise and colocation environments. The vertical mounting orientation is particularly useful in cabinets where horizontal space is limited or where cable management requires front-to-back airflow optimization.
Data Center Rack Power
Deploy in standard 19-inch racks to distribute power to an entire rack of equipment, with the vertical design minimizing footprint and improving cable routing.
- Fits 40U rack spaces
- Vertical mounting saves horizontal space
- Ideal for high-density server racks
Network Equipment Support
Power multiple switches, routers, and firewalls with the mixed outlet types, ensuring compatibility with both standard and high-power networking gear.
- Supports PoE switches
- Compatible with high-power devices
- Reduces cable clutter
Physical Profile
The PDU features a compact black housing measuring 72" (1828.8 mm) in height, 2.20" (55.88 mm) in width, and 3" (76.2 mm) in depth, designed specifically for vertical mounting in standard server racks. Its 40U rack height compatibility ensures it fits most common cabinet configurations without modification.
- Width
- 2.20" (55.88 mm)
- Depth
- 3" (76.20 mm)
- Height
- 40U
- Length
- 10 ft (3.05 m)
What's in the Box
The package includes the G6 42-Outlet PDU unit along with all necessary mounting hardware for secure installation in standard server racks.
Highlights
- 42 total outlets with mixed C13/C15/C19/C21 receptacles
- 17.3 kW power capacity with 230V AC input and 208V output
- Monitored and switched PDU with SNMP management
- Vertical rack-mount design for 40U server cabinets
- Three-phase power with IEC 60309 3P+E 9H 60A input connector
- Onboard display for real-time power monitoring
- 60A input current rating for high-density loads
- 10 ft (3.05 m) power cord included
- Operating temperature range of 50°F to 140°F (10°C to 60°C)
- 3-year limited warranty
Specifications
| Specifications | |
|---|---|
| Manufacturer | PANDUIT CORP |
| Manufacturer Part Number | P42E24G |
| Brand Name | Panduit |
| Product Series | G6 |
| Product Name | G6 42-Outlets PDU |
| Packaged Quantity | 1 |
| Product Type | PDU |
| Technical Information | |
| PDU Type | Monitored,Switched |
| Phase | Three Phase |
| Plug/Connector Type | IEC 60309 3P+E 9H 60A (IP44) |
| Receptacle Type | IEC 60320 C13/C15,IEC 60320 C13/C15/C19/C21 |
| Receptacle Detail | 21 x IEC 60320 C13/C15,21 x IEC 60320 C13/C15/C19/C21 |
| Features | Onboard Display |
| Load Capacity (Watt) | 17.30 kW |
| Power Description | |
| Input Voltage | 230 V AC |
| Output Voltage | 208 V AC |
| Power Rating (Watt) | 17.30 kW |
| Input Current | 60 A |
| Input Frequency | 60 Hz |
| Management | |
| Management | SNMP |
| Interfaces/Ports | |
| Network (RJ-45) | Yes |
| Physical Characteristics | |
| Product Color | Black |
| Mounting Orientation | Vertical |
| Mount Type | Rack-mountable |
| Rack Height | 40U |
| Cord Length | 10 ft (3.05 m) |
| Height | 72" (1828.80 mm) |
| Width | 2.20" (55.88 mm) |
| Depth | 3" (76.20 mm) |
| Environmental Conditions | |
| Minimum Operating Temperature | 50°F (10°C) |
| Maximum Operating Temperature | 140°F (60°C) |
| Minimum Storage Temperature | 24.8°F (-4°C) |
| Maximum Storage Temperature | 284°F (140°C) |
| Miscellaneous | |
| Package Contents | G6 42-Outlets PDU Mounting Hardware |
| Warranty | |
| Limited Warranty | 3 Year |
User Manual
FAQ
What is the power capacity of this Panduit PDU?
This Panduit G6 PDU has a power capacity of 17.3 kW (17,300 watts) with a 60A input current rating. It accepts 230V AC input and delivers 208V AC output across all 42 outlets, making it suitable for powering high-density server and networking equipment in data center environments.
How many outlets does this PDU have and what types?
The PDU features 42 total outlets: 21 IEC 60320 C13/C15 outlets and 21 mixed IEC 60320 C13/C15/C19/C21 outlets. This combination supports both standard server power cords (C13) and higher-power devices requiring C19 or C21 connectors, providing flexibility for diverse equipment configurations.
Can this PDU be mounted in a standard server rack?
Yes, this PDU is designed for vertical rack mounting in standard 19-inch server cabinets. It occupies 40U of vertical space with dimensions of 72" height x 2.20" width x 3" depth. The vertical orientation saves horizontal rack space and includes all necessary mounting hardware for secure installation.
What management capabilities does this PDU offer?
This is a monitored and switched PDU with SNMP management via an RJ-45 network port. It allows remote monitoring of power consumption, voltage, and temperature, plus individual outlet control for rebooting equipment. The onboard display provides local visibility of key metrics without requiring network access.
What type of power input does this PDU require?
The PDU requires a three-phase power input using an IEC 60309 3P+E 9H 60A connector with IP44 rating. It operates at 230V AC, 60 Hz, which is compatible with common North American and international three-phase power systems in data centers and commercial buildings.
What is included in the warranty for this PDU?
Panduit provides a 3-year limited warranty for this G6 42-Outlet PDU. The warranty covers defects in materials and workmanship under normal use. For complete warranty terms and conditions, refer to the manufacturer's documentation included with the product or available through their official support channels.
What power capacity is listed for this UPS?
The listed power specification is 17.30 kW, which helps position the unit for the right load level and installation role.
What voltage details are listed?
The listed power specification is 230 V AC, which helps position the unit for the right load level and installation role.