Panduit P36D26M-BL2C SmartZone G5 Intelligent Monitored Rack PDU - 36 Outlets - 30x C13 - 6x C19 - 208V AC - 8. 3 kW - 0U Vertical
Business volume discounts
Technical guidance
Preparation & staging
QC · ON · AB · BC
Product Features
Technical Overview
This SmartZone G5 PDU operates on 208V AC single-phase power with matching input and output voltage, ensuring stable power delivery without voltage conversion. The 30A input current capacity supports the full 8.3 kW power rating, providing ample headroom for high-density rack deployments. Network connectivity via RJ-45 enables remote monitoring and management through Panduit's intelligent platform.
The PDU features Hubbell CS8265C plug/connector type for reliable power input connection. All 36 outlets maintain 208V AC output, with the mixed receptacle configuration accommodating both standard C13 and high-power C19 equipment connections. This technical design ensures compatibility with enterprise-grade IT infrastructure while supporting power monitoring capabilities.
Monitoring Capabilities
Network connectivity allows for real-time power monitoring at both the PDU and individual outlet levels, enabling proactive management of power consumption and early detection of potential issues.
- Outlet-level monitoring
- Remote management access
- Power usage analytics
Key Product Advantages
The SmartZone G5 PDU combines high power capacity with intelligent monitoring in a zero-rack-unit design, maximizing rack space utilization while providing critical power management capabilities. Its 36-outlet configuration with mixed receptacle types offers exceptional flexibility for diverse equipment deployments.
Space-Efficient Design
The 0U vertical mounting orientation preserves valuable rack space for equipment while providing full power distribution capabilities along the rack's side or rear.
- Zero rack units consumed
- Vertical space utilization
- No equipment bay sacrifice
Intelligent Power Management
Network monitoring capabilities transform this from a basic power strip to a managed infrastructure component, providing visibility and control over power consumption patterns.
- Real-time power monitoring
- Outlet-level control
- Energy optimization data
Deployment / Use Cases
This PDU is engineered for data center environments where high-density server deployments require both substantial power capacity and intelligent power management. The 36-outlet configuration supports multiple equipment racks with mixed device types, from standard servers to high-power storage arrays and networking switches.
Ideal for colocation facilities, enterprise data centers, and server rooms implementing power monitoring initiatives, the SmartZone G5 enables detailed power usage tracking for capacity planning, billing allocation, and efficiency improvements. The vertical 0U mounting makes it particularly valuable in fully populated racks where front and rear space is at a premium.
Data Center Power Distribution
Deploy in server racks supporting virtualized environments, cloud infrastructure, or high-performance computing clusters where power monitoring and high outlet density are critical requirements.
- Virtualization clusters
- Cloud infrastructure racks
- HPC deployments
Managed Service Provider Environments
Provide clients with detailed power usage reporting and remote management capabilities in multi-tenant data center configurations where power accountability and uptime are paramount.
- Multi-tenant racks
- Power usage reporting
- Remote management access
Physical Profile
The PDU features a compact vertical design measuring 68.90 inches in length with a slim 2.05-inch width and 2.10-inch depth profile. This form factor allows installation along the full height of standard server racks without consuming equipment mounting space. The 0U rack height designation indicates side or rear mounting without using rack units, preserving all front-facing space for servers, switches, and other critical equipment.
- Width
- 2.05" (51.99 mm)
- Depth
- 2.10" (53.34 mm)
- Height
- 0U
- Length
- 68.90" (1750.01 mm)
Highlights
- 36 total outlets with 30 C13 and 6 C19 receptacles
- 8.3 kW power rating at 208V AC single-phase
- Intelligent monitored PDU with network management
- 0U vertical rack-mountable design
- 30A input current capacity
- Hubbell CS8265C plug/connector type
- RoHS compliant environmental design
- 3-year limited warranty coverage
Specifications
| Specifications | |
|---|---|
| Manufacturer | PANDUIT CORP |
| Manufacturer Part Number | P36D26M-BL2C |
| Brand Name | Panduit |
| Product Line | SmartZone |
| Product Series | MI |
| Product Name | SmartZone G5 Intelligent 36-Outlets PDU |
| Packaged Quantity | 1 |
| Product Type | PDU |
| Technical Information | |
| PDU Type | Monitored |
| Phase | Single Phase |
| Plug/Connector Type | CS8265C |
| Receptacle Type | IEC 60320 C13,IEC 60320 C19 |
| Receptacle Detail | 30 x IEC 60320 C13,6 x IEC 60320 C19 |
| Power Description | |
| Input Voltage | 208 V AC |
| Output Voltage | 208 V AC |
| Power Rating (Watt) | 8.30 kW |
| Input Current | 30 A |
| Interfaces/Ports | |
| Network (RJ-45) | Yes |
| Physical Characteristics | |
| Mounting Orientation | Vertical |
| Mount Type | Rack-mountable |
| Rack Height | 0U |
| Width | 2.05" (51.99 mm) |
| Depth | 2.10" (53.34 mm) |
| Length | 68.90" (1750.01 mm) |
| Miscellaneous | |
| Environmentally Friendly | Yes |
| Environmental Compliance | Restriction of Hazardous Substances (RoHS) |
| Warranty | |
| Limited Warranty | 3 Year |
User Manual
FAQ
What is the power capacity of this Panduit PDU?
This SmartZone G5 PDU has an 8.30 kW power rating operating at 208V AC with 30A input current. This capacity supports high-density server deployments and provides substantial headroom for multiple pieces of IT equipment while maintaining monitoring capabilities through the intelligent management system.
How many outlets does this PDU have and what types are they?
The PDU features 36 total outlets with a mixed configuration of 30 IEC 60320 C13 receptacles and 6 IEC 60320 C19 receptacles. This combination accommodates both standard server power cords (C13) and higher-power equipment requiring C19 connections, providing flexibility for diverse IT infrastructure deployments in rack environments.
What does 'monitored PDU' mean for this unit?
As a monitored PDU, this unit includes network connectivity via RJ-45 that enables remote monitoring and management of power consumption. This allows IT administrators to track power usage at both the PDU level and individual outlet level, receive alerts for power events, and optimize energy efficiency through the Panduit SmartZone management platform.
How is this PDU mounted in a server rack?
This PDU uses a 0U vertical mounting configuration, meaning it installs along the side or rear of the rack without consuming any rack units. The unit is designed for vertical orientation with dimensions of 68.90 inches in length to fit standard rack heights, preserving all front-facing rack space for servers, switches, and other equipment while providing full power distribution capabilities.
What voltage does this PDU require and deliver?
The PDU operates on 208V AC single-phase power, with both input and output voltages matching at 208V AC. This design ensures stable power delivery without voltage conversion, making it compatible with standard 208V data center power infrastructure while providing consistent voltage to all connected equipment through its 36 outlets.
What warranty coverage comes with this Panduit PDU?
Panduit provides a 3-year limited warranty for this SmartZone G5 Intelligent Monitored PDU. This warranty covers manufacturing defects and ensures reliable performance in data center environments. The unit is also RoHS compliant, meeting environmental standards for hazardous substance restrictions in its construction and materials.
What power capacity is listed for this UPS?
The listed power specification is 8.30 kW, which helps position the unit for the right load level and installation role.
What voltage details are listed?
The listed power specification is 208 V AC, which helps position the unit for the right load level and installation role.