Raritan PX4-5551I3-E7V2 Switched PDU with Metered-by-Outlet - 24 Outlets - 17. 3 kW - 208V Three Phase - Rack-Mountable
Business volume discounts
Technical guidance
Preparation & staging
QC · ON · AB · BC
Product Features
Technical Overview
This PDU operates on a three-phase power system with 208V AC input and output, supporting a voltage range of 190-208V AC. The 60A input current and 60Hz frequency align with North American power standards, while the 17.3 kVA power rating provides substantial capacity for dense equipment deployments.
The metered-by-outlet functionality is complemented by a multi-color LCD display for local monitoring. Protection mechanisms include overload protection and branch circuit safeguards to prevent electrical faults. The unit maintains operation in temperatures up to 140°F (60°C) and humidity levels from 5% to 95%, ensuring reliability in controlled environments.
This section brings together practical product details such as PDU Type, Phase, Plug/Connector Type, Input Voltage, so buyers can judge configuration, deployment fit, and day-to-day suitability with less guesswork.
A strong technical summary explains how the product's interfaces, hardware profile, and operating characteristics work together in real deployment. Buyers often need this context to confirm compatibility with existing devices, expected performance in daily use, and whether installation will be straightforward for IT staff or end users.
Key Product Advantages
The PX4-5551I3-E7V2 combines high-density power distribution with intelligent management features that optimize data center operations. Per-outlet metering provides precise power consumption data for individual devices, enabling accurate capacity planning and energy efficiency initiatives.
Granular Power Monitoring
Monitor power usage at each of the 24 outlets independently, allowing for detailed analysis of equipment consumption patterns and identification of inefficient devices.
- Per-outlet current monitoring
- Real-time power data
- Historical consumption tracking
Comprehensive Management
Access the PDU through multiple protocols including HTTP(s), SSH, SNMP, and Redfish API for integration with existing data center management systems.
- Multi-protocol support
- Remote configuration
- API integration capabilities
High-Density Design
The 24-outlet configuration in a standard rack-width form factor maximizes power distribution capacity within limited rack space.
- Space-efficient design
- Mixed receptacle types
- Rack-optimized footprint
Deployment / Use Cases
This switched PDU with metered-by-outlet functionality is engineered for environments requiring precise power management and remote control capabilities. Data centers implementing power usage effectiveness (PUE) optimization strategies benefit from the detailed consumption data provided by per-outlet monitoring.
Server rooms with mixed equipment types utilize the combination of C13 and CX receptacles to power both standard IT equipment and specialized devices. The three-phase 208V architecture makes this PDU particularly suitable for larger rack deployments where single-phase solutions would create phase imbalance issues.
Data Center Power Management
Deploy in colocation facilities or enterprise data centers to monitor power consumption at the device level, supporting capacity planning and billing accuracy for hosted equipment.
High-Density Server Racks
Install in racks containing multiple servers, storage arrays, and networking equipment where remote power control and monitoring reduce the need for physical access to equipment.
Physical Profile
The PDU features a compact 2.2-inch width that fits standard rack profiles without consuming excessive horizontal space. With dimensions of 70.10" height, 2.20" width, and 2.60" depth, the unit maximizes vertical space utilization in rack enclosures. The black powder coat finish provides durability and a professional appearance that blends with data center aesthetics.
Button mount and rack-mountable installation options offer flexibility for different rack configurations. The included 9.8-foot (3-meter) power cord provides adequate reach to power sources, while the 27.6-pound weight indicates robust construction suitable for continuous operation in demanding environments.
- Width
- 2.20" (55.88 mm)
- Depth
- 2.60" (66.04 mm)
- Height
- 70.10" (1780.54 mm)
- Weight
- 27.60 lb (12520 g)
- Length
- 9.8 ft (3 m)
Highlights
- 24 total outlets with 12 C13 and 12 CX receptacles for mixed equipment support
- Metered-by-outlet functionality provides per-outlet power monitoring
- 17.3 kW load capacity and 17.3 kVA power rating for high-density deployments
- Three-phase 208V input and output with 190-208V operating range
- Remote outlet switching via network management interfaces
- Multi-protocol management including HTTP(s), SNMP, and Redfish API
- Rack-mountable design with black powder coat finish
- Overload protection and branch circuit safeguards
- RoHS compliant with 2-year limited warranty
- Operates in temperatures up to 140°F (60°C)
Specifications
| Specifications | |
|---|---|
| Manufacturer | Legrand Group |
| Manufacturer Part Number | PX4-5551I3-E7V2 |
| Brand Name | Raritan |
| Product Series | PX4 |
| Product Model | PX4-5551I3-E7V2 |
| Product Name | PX4-5551I3-E7V2 24-Outlets PDU |
| Product Type | PDU |
| Technical Information | |
| PDU Type | Switched with Metered-by-Outlet |
| Phase | Three Phase |
| Plug/Connector Type | IEC 60309 3P+N+E 9h 60A (4P5W) |
| Receptacle Type | IEC 60320 C13,CX |
| Receptacle Detail | 12 x IEC 60320 C13,12 x CX |
| Protection Type | Overload Protection,Branch Circuit |
| Locking Receptacles | IEC 60320 C13,CX |
| Features | Multi-color LCD |
| Load Capacity (VA) | 17.30 kW |
| Power Description | |
| Input Voltage | 208 V AC |
| Input Voltage Range | 190 V AC - 208 V AC |
| Output Voltage | 208 V AC |
| Output Voltage Range | 190 V AC - 208 V AC |
| Power Rating (VA) | 17.30 kVA |
| Input Current | 60 A |
| Input Frequency | 60 Hz |
| Management | |
| Management | HTTP(s) SSH (CLI) Telnet RS-232 (Serial) SNMP version v2/v3 SMTP JSON-RPC API MODBUS-TCP Redfish API |
| Remote Outlet Switching | Yes |
| Interfaces/Ports | |
| Network (RJ-45) | Yes |
| Physical Characteristics | |
| Color Family | Black |
| Product Color | Black Powder Coat |
| Mount Type | Button Mount,Rack-mountable |
| Cord Length | 9.8 ft (3 m) |
| Height | 70.10" (1780.54 mm) |
| Width | 2.20" (55.88 mm) |
| Depth | 2.60" (66.04 mm) |
| Weight (Approximate) | 27.60 lb (12520 g) |
| Environmental Conditions | |
| Maximum Operating Temperature | 140°F (60°C) |
| Minimum Storage Temperature | -22°F (-30°C) |
| Maximum Storage Temperature | 176°F (80°C) |
| Minimum Operating Humidity | 5% |
| Maximum Operating Humidity | 95% |
| Miscellaneous | |
| Environmental Compliance | Restriction of Hazardous Substances (RoHS) |
| Warranty | |
| Limited Warranty | 2 Year |
User Manual
FAQ
What is the power capacity of this PDU?
The Raritan PX4-5551I3-E7V2 has a load capacity of 17.30 kW and a power rating of 17.30 kVA. This substantial capacity supports high-density equipment deployments in server racks and data center environments, making it suitable for powering multiple servers, storage devices, and networking equipment simultaneously.
How many outlets does this PDU have and what types are they?
This PDU features 24 total outlets configured as 12 IEC 60320 C13 receptacles and 12 CX receptacles. This mixed configuration allows you to power both standard IT equipment (using C13 connections) and specialized devices requiring CX connectors, providing flexibility for diverse equipment types within the same rack.
What management options are available for this switched PDU?
The PDU supports multiple management protocols including HTTP(s), SSH (CLI), Telnet, RS-232 serial, SNMP versions v2 and v3, SMTP, JSON-RPC API, MODBUS-TCP, and Redfish API. This comprehensive protocol support enables integration with existing data center management systems and allows remote monitoring and control from various platforms.
What voltage does this PDU require and deliver?
This PDU operates on three-phase 208V AC power, with both input and output rated at 208V AC. The unit supports an operating range of 190-208V AC, providing compatibility with standard North American three-phase power systems commonly found in data centers and commercial buildings.
Is this PDU rack-mountable and what are its dimensions?
Yes, the PDU is designed for rack mounting with button mount and rack-mountable installation options. Its dimensions are 70.10 inches in height, 2.20 inches in width, and 2.60 inches in depth, allowing it to fit standard 19-inch rack enclosures while maximizing vertical space utilization for high-density power distribution.
What protection features does this PDU include?
The PDU incorporates overload protection and branch circuit safeguards to prevent electrical faults and protect connected equipment. These protection mechanisms help ensure reliable operation and reduce the risk of damage to sensitive IT equipment from power anomalies or excessive current draw.
What power capacity is listed for this UPS?
The listed power specification is 17.30 kW, which helps position the unit for the right load level and installation role.
How many outlets are available?
The product includes Yes, which helps buyers understand how many connected devices it can support in its intended deployment.