Server Technology C-12HEK211 12-Outlet Metered PDU - 7. 3 kW Load Capacity - 230V AC - 1U Rack-Mountable - IEC C13 Outlets
Business volume discounts
Technical guidance
Preparation & staging
QC · ON · AB · BC
Product Features
Technical Overview
This metered PDU operates at 230V AC with a 32A input current and 60 Hz frequency, supporting a maximum load of 7.30 kW. The IEC 2P+PE 6Hr 230V/32A plug connector provides a secure, high-current input link, while the 12 IEC 60320 C13 outlets distribute power to servers, switches, storage arrays, and other rack-mounted devices.
The integrated LED display offers at-a-glance load monitoring, helping prevent circuit overloads and supporting capacity planning. Electrical protection includes branch circuit and fuse safeguards, which help isolate faults and protect downstream equipment from power anomalies.
This section brings together practical product details such as PDU Type, Plug/Connector Type, Receptacle Type, Input Voltage, so buyers can judge configuration, deployment fit, and day-to-day suitability with less guesswork.
A strong technical summary explains how the product's interfaces, hardware profile, and operating characteristics work together in real deployment. Buyers often need this context to confirm compatibility with existing devices, expected performance in daily use, and whether installation will be straightforward for IT staff or end users.
Key Product Advantages
The C-12HEK211 combines high-density power distribution with visibility and protection features that are critical for modern IT environments. Its metering capability allows data center managers to monitor power draw accurately, supporting energy efficiency initiatives and helping avoid overload conditions that could lead to downtime.
Load Monitoring
The built-in LED display provides real-time power consumption data, enabling proactive load management and capacity optimization across the rack.
- Visual load indication
- Prevents circuit overloads
- Supports power usage reporting
Secure Connections
P-Lock receptacles keep power cords firmly seated, reducing the risk of accidental disconnections that could interrupt critical equipment.
- Prevents cord pull-out
- Enhances rack stability
- Reduces maintenance interventions
Electrical Protection
Branch circuit and fuse protection help safeguard connected devices from electrical faults, adding a layer of reliability to the power distribution chain.
- Fault isolation
- Equipment protection
- Compliance with safety standards
Deployment / Use Cases
This PDU is designed for deployment in server racks, network cabinets, and data center rows where reliable, monitored power distribution is required. Its 1U height and 17.2-inch width make it compatible with standard 19-inch rack enclosures, while the 12 C13 outlets support a typical mix of servers, storage, and networking gear.
Ideal applications include enterprise data centers, colocation facilities, server rooms, and edge computing deployments where power monitoring helps manage operational costs and uptime. The 230V AC operation aligns with common three-phase power distribution in data centers, and the environmental tolerance from 32°F to 140°F ensures reliable operation in controlled IT spaces.
Data Center Racks
Deploy in standard 19-inch server racks to distribute power to multiple devices while monitoring total load through the integrated meter.
IT Equipment Cabinets
Use in network closets or server rooms to power switches, routers, and small servers with secure, protected outlets.
Physical Profile
The PDU measures 1.75 inches (44.45 mm) in height, 17.20 inches (436.88 mm) in width, and 5 inches (127 mm) in depth, occupying a single rack unit (1U) when mounted horizontally. This compact form factor maximizes usable rack space while providing 12 outlets. The unit is rated for operation in temperatures from 32°F to 140°F (0°C to 60°C) and storage from -22°F to 176°F (-30°C to 80°C), suitable for controlled IT environments.
- Width
- 17.20" (436.88 mm)
- Depth
- 5" (127 mm)
- Height
- 1U
Highlights
- 12 IEC C13 outlets with P-Lock securing for reliable connections
- 7.30 kW total load capacity supports high-density rack equipment
- Integrated LED display for real-time power consumption monitoring
- 1U rack-mount design fits standard 19-inch server racks
- 230V AC input and output voltage for data center compatibility
- Branch circuit and fuse protection enhances electrical safety
- IEC 2P+PE 6Hr 230V/32A input connector for secure power feed
- Operating temperature range of 32°F to 140°F (0°C to 60°C)
Specifications
| Specifications | |
|---|---|
| Manufacturer | Legrand Group |
| Manufacturer Part Number | C-12HEK211 |
| Brand Name | Server Technology |
| Product Name | 12-Outlets PDU |
| Product Type | PDU |
| Technical Information | |
| PDU Type | Metered |
| Plug/Connector Type | IEC 2P+PE 6Hr 230V/32A |
| Receptacle Type | IEC 60320 C13 |
| Receptacle Detail | 12 x IEC 60320 C13 |
| Protection Type | Branch Circuit,Circuit Protection,Fuse |
| Locking Receptacles | P-Lock |
| Features | LED Display |
| Load Capacity (Watt) | 7.30 kW |
| Power Description | |
| Input Voltage | 230 V AC |
| Output Voltage | 230 V AC |
| Input Current | 32 A |
| Input Frequency | 60 Hz |
| Physical Characteristics | |
| Mount Type | Rack-mountable,Cabinet-mountable |
| Rack Height | 1U |
| Height | 1.75" (44.45 mm) |
| Width | 17.20" (436.88 mm) |
| Depth | 5" (127 mm) |
| Environmental Conditions | |
| Minimum Operating Temperature | 32°F (0°C) |
| Maximum Operating Temperature | 140°F (60°C) |
| Minimum Storage Temperature | -22°F (-30°C) |
| Maximum Storage Temperature | 176°F (80°C) |
| Miscellaneous | |
| Application/Usage | Server Rack/Cabinet,IT Equipment,Data Center |
FAQ
What is the load capacity of this PDU?
The Server Technology C-12HEK211 PDU supports a maximum load capacity of 7.30 kW (7300 watts). This capacity allows it to power multiple servers, storage devices, and networking equipment within a single rack while maintaining safe operating margins.
How many outlets does this PDU have and what type are they?
This PDU features 12 IEC 60320 C13 outlets. These are standard three-prong connectors commonly used for servers, switches, and other rack-mounted IT equipment. The outlets include P-Lock mechanisms to secure power cords and prevent accidental disconnections.
What does 'metered' mean for this PDU?
A metered PDU includes an integrated display that shows real-time power consumption. This model has an LED display that allows you to monitor the total electrical load being drawn through the unit, helping to prevent circuit overloads and optimize power usage in the rack.
What rack mounting options are supported?
The PDU is designed for rack or cabinet mounting with a 1U height profile. It measures 17.20 inches wide, making it compatible with standard 19-inch rack enclosures. The unit can be mounted horizontally in a rack to distribute power to equipment installed above and below.
What input voltage and connector does this PDU use?
This PDU operates at 230 volts AC with a 32-amp input current. It uses an IEC 2P+PE 6Hr 230V/32A plug connector, which is a high-current, locking-style connector commonly used in data center power distribution systems.
What protection features does this PDU include?
The PDU includes branch circuit and fuse protection. These features help isolate electrical faults and protect connected equipment from power anomalies. The protection mechanisms work alongside the metering function to enhance overall electrical safety and reliability in the rack.
What power capacity is listed for this UPS?
The listed power specification is 7.30 kW, which helps position the unit for the right load level and installation role.
What voltage details are listed?
The listed power specification is 230 V AC, which helps position the unit for the right load level and installation role.