Shipping included*
Exclusions
Additional shipping fees may apply in rare circumstances for deliveries outside standard service areas. In most cases, this only potentially affects shipments to the Northwest Territories and Yukon, as well as certain heavy or oversized items.
Server Technology C3WG36RL-YQJE2MT2 Switched POPS PDU - 17. 3kW - 36 Outlets - 208V - 60A - Rack-Mountable
Business volume discounts
Technical guidance
Preparation & staging
QC · ON · AB · BC
Product Features
Technical Overview
This PDU operates on three-phase power with an IEC 60309 3P+N+G 9Hr 60A input connector, delivering balanced power distribution across all phases. The 17.3kW power rating ensures sufficient capacity for modern high-density server deployments, while the 208V input voltage matches standard North American three-phase power configurations.
The unit incorporates comprehensive protection circuitry including overcurrent, overload, and circuit protection mechanisms to safeguard connected equipment. The network-enabled switched functionality provides granular control over power delivery, with the ability to monitor and manage individual outlets through standard network protocols.
This section brings together practical product details such as PDU Type, Phase, Plug/Connector Type, Input Voltage, so buyers can judge configuration, deployment fit, and day-to-day suitability with less guesswork.
A strong technical summary explains how the product's interfaces, hardware profile, and operating characteristics work together in real deployment. Buyers often need this context to confirm compatibility with existing devices, expected performance in daily use, and whether installation will be straightforward for IT staff or end users.
Key Product Advantages
This PDU combines high power capacity with intelligent management features, providing both robust power distribution and remote control capabilities essential for modern data center operations.
Remote Outlet Management
Individually control each of the 36 outlets through the network interface, enabling remote rebooting of equipment without physical access to the data center.
- Reduce downtime
- Minimize on-site visits
- Schedule power cycles
High-Density Power Distribution
Deliver 17.3kW of power through 36 strategically placed outlets, supporting dense server and networking deployments in limited rack space.
- 17.3kW capacity
- 36 total outlets
- Balanced three-phase power
Comprehensive Protection
Built-in overcurrent, overload, and circuit protection mechanisms safeguard connected equipment from power anomalies and electrical faults.
- Equipment protection
- Fault isolation
- Reliable operation
Deployment / Use Cases
This switched PDU is designed for data centers, server rooms, and network closets where reliable power distribution and remote management are critical. The three-phase 208V configuration makes it particularly suitable for North American commercial and enterprise environments with three-phase power infrastructure.
The unit's rack-mountable form factor and compact 2U profile allow for efficient use of vertical rack space. The combination of C13 and CX receptacles provides compatibility with a wide range of server, storage, and networking equipment, from 1U servers to larger chassis-based systems.
Data Center Power Distribution
Deploy in server racks to distribute three-phase power to multiple pieces of equipment while maintaining remote management capabilities for each outlet.
High-Density Server Environments
Support blade server chassis, high-performance computing clusters, and storage arrays that require substantial power capacity and outlet density.
Physical Profile
The PDU features a rack-optimized design measuring 70" in height (1778 mm), 2.20" in width (55.88 mm), and 2.50" in depth (63.50 mm). This vertical orientation maximizes outlet density while minimizing horizontal rack space consumption. The unit is designed for standard 19" rack mounting with appropriate mounting hardware included.
The physical profile is practical for deployment planning because the dimensions and weight are clearly defined: 70" (1778 mm), 2.20" (55.88 mm), 2.50" (63.50 mm). This helps confirm rack, shelf, desk, or cabinet fit before installation.
- Width
- 2.20" (55.88 mm)
- Depth
- 2.50" (63.50 mm)
- Height
- 70" (1778 mm)
What's in the Box
The package includes the complete Switched POPS PDU unit with all necessary mounting hardware for installation in standard server racks.
Package contents include Switched POPS PDU - 17.3kW, C3WG36RL-YQJE2MT2 Button Mounts, Switched POPS PDU - 17.3kW, C3WG36RL-YQJE2MT2. These included items support setup, installation, and immediate deployment without needing to source the core bundled accessories separately.
Highlights
- 17.3kW power capacity for high-density deployments
- 36 total outlets (18 x C13, 18 x CX) for flexible connectivity
- Three-phase 208V input with 60A current rating
- Switched PDU design with remote outlet management
- Network interface (RJ-45) for remote monitoring and control
- Rack-mountable form factor with vertical orientation
- Comprehensive protection: overcurrent, overload, circuit
- IEC 60309 3P+N+G 9Hr 60A input connector
- Made in the United States
- 2-year limited warranty
Specifications
| Specifications | |
|---|---|
| Manufacturer | Legrand Group |
| Manufacturer Part Number | C3WG36RL-YQJE2MT2 |
| Brand Name | Server Technology |
| Product Line | PRO3X |
| Product Series | Switched |
| Product Model | C3WG36RL-YQJE2MT2 |
| Product Name | Switched POPS PDU - 17.3kW, C3WG36RL-YQJE2MT2 |
| Product Type | PDU |
| Technical Information | |
| PDU Type | Switched |
| Phase | Three Phase |
| Plug/Connector Type | IEC 60309 3P+N+G 9Hr 60A |
| Plug/Connector Detail | 1 x IEC 60309 3P+N+G 9Hr 60A |
| Receptacle Type | IEC 60320 C13,CX |
| Receptacle Detail | 18 x IEC 60320 C13,18 x CX |
| Protection Type | Overcurrent Protection,Overload Protection,Circuit Protection |
| Power Description | |
| Input Voltage | 208 V |
| Power Rating (Watt) | 17.30 kW |
| Input Current | 60 A |
| Interfaces/Ports | |
| Network (RJ-45) | Yes |
| Physical Characteristics | |
| Mount Type | Rack-mountable |
| Form Factor | Rack/Tower |
| Height | 70" (1778 mm) |
| Width | 2.20" (55.88 mm) |
| Depth | 2.50" (63.50 mm) |
| Miscellaneous | |
| Package Contents | Switched POPS PDU - 17.3kW, C3WG36RL-YQJE2MT2 Button Mounts |
| Country of Origin | United States |
| Warranty | |
| Limited Warranty | 2 Year |
FAQ
What is the power capacity of this PDU?
This Server Technology PDU delivers 17.3 kilowatts (kW) of power capacity, which translates to 17,300 watts. This substantial capacity supports high-density server deployments and can power multiple racks of equipment simultaneously in data center environments.
How many outlets does this PDU have and what types?
The PDU features 36 total outlets, with 18 IEC 60320 C13 receptacles and 18 CX receptacles. This combination provides compatibility with a wide range of server, networking, and storage equipment, allowing for flexible power distribution in mixed-equipment environments.
What input voltage and current does this PDU require?
This unit requires three-phase 208-volt (V) input power with a 60-ampere (A) current rating. This configuration is standard for North American commercial three-phase power systems and provides balanced power distribution across all three phases for efficient operation.
What does 'switched' mean for this PDU?
A switched PDU allows individual control of each outlet through a network interface. This enables remote power cycling of connected equipment, scheduled power management, and monitoring of power consumption at the outlet level without physical access to the data center or server room.
Is this PDU rack-mountable and what are its dimensions?
Yes, this PDU is designed for rack mounting with dimensions of 70 inches in height (1778 mm), 2.20 inches in width (55.88 mm), and 2.50 inches in depth (63.50 mm). The vertical orientation maximizes outlet density while consuming minimal horizontal rack space, typically equivalent to 2U of vertical rack space.
What protection features does this PDU include?
The PDU incorporates multiple protection mechanisms including overcurrent protection, overload protection, and circuit protection. These features help safeguard connected equipment from electrical faults, power surges, and other anomalies that could damage sensitive server and networking hardware.
What power capacity is listed for this UPS?
The listed power specification is 17.30 kW, which helps position the unit for the right load level and installation role.
What voltage details are listed?
The listed power specification is 208 V, which helps position the unit for the right load level and installation role.