The Tripp Lite by Eaton AVR750UNC is a 750VA/450W line-interactive UPS engineered to deliver reliable power protection for critical business electronics and equipment. This unit combines automatic voltage regulation (AVR) with battery backup capabilities to maintain stable power output during voltage fluctuations and short outages, ensuring connected devices receive clean, consistent power.
Designed for deployment flexibility, the AVR750UNC supports surface, desktop, tower, and wall mounting configurations, making it suitable for diverse environments from network closets to point-of-sale stations. With 6 battery-backed surge outlets and 6 surge-only outlets, it provides comprehensive protection for connected devices while maintaining clean power delivery through its pulse-width modulated sine wave output. The unit's compact footprint and manageable weight allow for easy integration into various setups without occupying excessive space.
This UPS operates with a 6ms transfer time, ensuring seamless transition to battery power during outages. The automatic voltage regulation corrects input voltage sags and surges within the 89-145 V AC range without draining the battery, extending runtime and battery life. Management capabilities include USB and network (RJ-45) connectivity for monitoring and control, supported by an LED display that provides clear status indicators for line/battery mode, low battery, fault conditions, and overload.
Technical Overview
This line-interactive UPS operates with a 6ms transfer time, ensuring seamless transition to battery power during outages. The automatic voltage regulation corrects input voltage sags and surges within the 89-145 V AC range without draining the battery, extending runtime and battery life. The unit features a 12 V DC valve-regulated lead-acid battery system that delivers 3 minutes of runtime at full 450W load and extends to 11 minutes at half load.
Management capabilities include USB and network (RJ-45) connectivity for monitoring and control, supported by an LED display that provides clear status indicators for line/battery mode, low battery, fault conditions, and overload. Built-in protection features include EMI/RFI noise filtering, 316-joule surge energy rating, circuit breaker protection, and audible alarms for critical events.
Relevant product facts for this section include AVR: Yes, Plug/Connector Type: NEMA 5-15P, Receptacle Type: NEMA 5-15R, Load Capacity (VA): 750 VA. When those details are considered together, they give buyers a clearer picture of how the product is equipped, how it connects, and what kind of day-to-day role it is meant to support.
Key Product Advantages
The AVR750UNC delivers essential power protection with practical advantages for business continuity. Its combination of AVR technology and battery backup ensures connected equipment receives clean, stable power during both minor voltage variations and complete outages.
Flexible Deployment
Four mounting options allow installation in space-constrained environments, from under-desk placement to wall-mounted network installations.
- Surface mounting for flat placement
- Desktop configuration for office use
- Tower orientation for floor placement
- Wall mounting to conserve space
Comprehensive Protection
Multiple layers of protection safeguard connected equipment from various power quality issues.
- AVR corrects voltage sags/surges
- Battery backup for outages
- Surge suppression on all outlets
- EMI/RFI noise filtering
Deployment / Use Cases
The AVR750UNC is engineered to protect critical business systems where power reliability is essential. Its 750VA capacity and flexible mounting make it suitable for a range of commercial and light industrial applications.
In retail environments, it secures point-of-sale systems, digital signage, and payment terminals against data loss during brief outages. For office deployments, it protects desktop computers, network routers, and VoIP equipment while maintaining productivity. The unit also serves security applications by ensuring surveillance systems, access control panels, and alarm systems remain operational during power disturbances.
Relevant product facts for this section include AVR: Yes, Plug/Connector Type: NEMA 5-15P, Receptacle Type: NEMA 5-15R, Load Capacity (VA): 750 VA. When those details are considered together, they give buyers a clearer picture of how the product is equipped, how it connects, and what kind of day-to-day role it is meant to support.
Network Infrastructure
Protects routers, switches, and network-attached storage to maintain connectivity during power events.
Business Critical Systems
Safeguards computers, peripherals, and communication equipment in office and retail environments.
Physical Profile
With compact dimensions of 4.13 inches high, 7.48 inches wide, and 12.01 inches deep, the AVR750UNC fits efficiently in various installation scenarios. The 15.84-pound weight provides stability while remaining manageable for placement adjustments. The unit includes a 5-foot power cord for convenient connection to standard NEMA 5-15R outlets.
The physical profile is practical for deployment planning because the dimensions and weight are clearly defined: 4.13" (105 mm), 7.48" (190 mm), 12.01" (305 mm), 15.84 lb (7184.90 g). This helps confirm rack, shelf, desk, or cabinet fit before installation.
- Width
- 7.48" (190 mm)
- Depth
- 12.01" (305 mm)
- Height
- 4.13" (105 mm)
- Weight
- 15.84 lb (7184.90 g)
- Length
- 5 ft (1.52 m)
What's in the Box
The package includes the complete UPS unit with all necessary components for immediate deployment.
Highlights
- 750VA/450W line-interactive UPS with automatic voltage regulation
- 3-minute runtime at full load, 11 minutes at half load
- 6 battery/surge outlets plus 6 surge-only outlets for comprehensive protection
- Flexible surface, desktop, tower, and wall mounting options
- USB and network connectivity for management and monitoring
- Energy Star certified for energy efficiency
- Pulse-width modulated sine wave output for compatible equipment
- 3-year limited warranty for long-term reliability
Specifications
| Specifications | |
|---|---|
| Manufacturer | Eaton Corporation |
| Manufacturer Part Number | AVR750UNC |
| Brand Name | Tripp Lite series |
| Product Model | AVR750UNC |
| Product Name | AVR750UNC 750VA Surface/Desktop/Tower/Wall Mountable UPS |
| Product Type | Line-interactive UPS |
| Technical Information | |
| AVR | Yes |
| Plug/Connector Type | NEMA 5-15P |
| Receptacle Type | NEMA 5-15R |
| Receptacle Detail | 12 x NEMA 5-15R |
| Number of Battery & Surge Outlets | 6 |
| Number of Surge-only Outlets | 6 |
| Overload Protection | Yes |
| Cord Length | 5 ft (1.52 m) |
| Transfer Time | 6 ms |
| EMI/RFI Noise Filter | Yes |
| Phase | Single Phase |
| Energy Saving | Green Energy-Saving |
| Application/Usage | Equipment,Digital Signage,Home/Office,Network,Computer,Router,ATM,Security System,Desktop Computer,Computer Peripheral,Audio/Video Equipment,Tablet,Smartphone |
| Surge Suppression | Yes |
| Features | Audible Alarm,Cold Start Function |
| Power Description | |
| Load Capacity (VA) | 750 VA |
| Load Capacity (Watt) | 450 W |
| Input Voltage | 120 V AC |
| Input Voltage Range | 89 V AC - 145 V AC |
| Input Current | 20 A |
| Output Voltage | 120 V AC |
| Input Frequency | 50 Hz,60 Hz |
| Output Frequency | 50 Hz,60 Hz |
| Waveform Type | Pulse-width Modulated Sine Wave |
| Surge Energy Rating | 316 J |
| Circuit Breaker | Yes |
| Output Power Factor | 0.63 |
| Display & Graphics | |
| Display | LED |
| Management | |
| Network Management | Network Card |
| Alarm | Low Battery,Overload,Battery Mode,Replace Battery,Fault |
| Controls/Indicators | |
| Status Indicators | LED Indicators: Low Battery Fault Condition Line/battery Mode Status |
| Interfaces/Ports | |
| USB | Yes |
| Network (RJ-45) | Yes |
| Battery Information | |
| DC System Voltage | 12 V DC |
| Battery Characteristics | Valve-regulated |
| Battery Chemistry | Lead Acid |
| Backup/Run Time (Full Load) | 3 Minute |
| Backup/Run Time (Half Load) | 11 Minute |
| Typical Battery Recharge Time | 8 Hour |
| Replaceable Battery | Yes |
| Environmental Conditions | |
| Maximum Operating Elevation | 10000 ft (3048000 mm) |
| Storage Temperature | 5°F (-15°C) - 113°F (45°C) |
| Minimum Operating Temperature | 32°F (0°C) |
| Maximum Operating Temperature | 104°F (40°C) |
| Thermal Dissipation | 41 BTU/h |
| Physical Characteristics | |
| Height | 4.13" (105 mm) |
| Width | 7.48" (190 mm) |
| Depth | 12.01" (305 mm) |
| Form Factor | Surface/Desktop/Tower/Wall Mountable |
| Weight (Approximate) | 15.84 lb (7184.90 g) |
| Miscellaneous | |
| Package Contents | AVR750UNC 750VA Surface/Desktop/Tower/Wall Mountable UPS Quick Start Guide |
| Energy Star | Yes |
| Country of Origin | Vietnam |
| Environmental Compliance | Restriction of Hazardous Substances (RoHS),Waste Electrical and Electronic Equipment Directive (WEEE) |
| Warranty | |
| Limited Warranty | 3 Year |
User Manual
FAQ
What is the power capacity and watt rating of this UPS?
This UPS has a power capacity of 750 VA and a watt rating of 450 W, suitable for protecting critical business electronics like desktop computers, routers, and network equipment during power outages.
What runtime can I expect at full and half load?
At full load (450 W), the UPS provides 3 minutes of runtime, while at half load (225 W), it extends to 11 minutes, allowing time for safe shutdown or continued operation during brief power interruptions.
How many outlets does the AVR750UNC have, and what types are included?
The UPS includes 6 battery-backed surge outlets for protected power during outages and 6 surge-only outlets for additional surge protection, totaling 12 NEMA 5-15R receptacles to support multiple devices.
What input and output voltage specifications does this UPS support?
It operates with an input voltage of 120 V AC, within a range of 89-145 V AC, and delivers a stable output voltage of 120 V AC, making it compatible with standard North American electrical systems.
What mounting options are available for this UPS?
The AVR750UNC offers flexible mounting options including surface, desktop, tower, and wall configurations, allowing installation in various environments like offices, network closets, or retail spaces.
What management and connectivity features are included?