Shipping included*
Exclusions
Additional shipping fees may apply in rare circumstances for deliveries outside standard service areas. In most cases, this only potentially affects shipments to the Northwest Territories and Yukon, as well as certain heavy or oversized items.
Tripp Lite by Eaton SV140KL7P Tripp Lite SmartOnline 140kVA Tower UPS - Double Conversion Online - 120/230V AC Input/Output - Pure Sine Wave
Business volume discounts
Technical guidance
Preparation & staging
QC · ON · AB · BC
Product Features
Technical Overview
This double-conversion online UPS provides complete isolation from utility power anomalies by continuously converting AC input to DC and back to clean AC output. The 140 kVA capacity supports substantial three-phase loads, with input and output voltages configurable for 120 V AC or 230 V AC operation. Hardwired plug and receptacle connections ensure secure, high-current power delivery suitable for permanent installations.
The pure sine wave output guarantees compatibility with power factor corrected (PFC) servers, storage arrays, and networking equipment. Advanced battery management extends battery life while maintaining runtime readiness. The system's modular power architecture incorporates seven SV20PM 20kVA power modules for scalable redundancy and simplified maintenance.
This section brings together practical product details such as Plug/Connector Type, Receptacle Type, Phase, Load Capacity (VA), so buyers can judge configuration, deployment fit, and day-to-day suitability with less guesswork.
Key Product Advantages
The SmartOnline SV140KL7P combines industrial-grade power protection with flexible deployment options for demanding environments. Its dual-voltage capability eliminates the need for external transformers when transitioning between 120V and 230V power systems, simplifying installation in global facilities with varying electrical standards.
Zero Transfer Time Protection
Double-conversion technology ensures continuous power conditioning with no break in output during utility failures or transfers to battery power, protecting against data loss and equipment damage.
Comprehensive Remote Management
Built-in network interface supports SNMP, SSH, and Telnet protocols for monitoring power quality, configuring alerts, and managing shutdown sequences from any network location.
Modular Serviceability
Seven hot-swappable 20kVA power modules enable maintenance without system shutdown and provide N+1 redundancy options for maximum uptime in critical applications.
Deployment / Use Cases
This 140kVA tower UPS is engineered for environments where power reliability directly impacts operational continuity and revenue generation. The substantial power capacity and three-phase design make it suitable for protecting entire server rooms, manufacturing control systems, or telecommunications infrastructure where single-phase UPS units would be insufficient.
Healthcare facilities deploy these systems to maintain uninterrupted operation of diagnostic imaging equipment, laboratory analyzers, and patient monitoring systems. Financial institutions rely on them for trading floor infrastructure, ATM networks, and data processing centers where even momentary power disturbances can result in significant financial exposure.
Data Center Power Distribution
Protect server racks, storage arrays, and network core switches with clean, regulated power that maintains uptime during utility fluctuations and extended outages.
Industrial Process Control
Ensure continuous operation of PLC systems, SCADA networks, and manufacturing automation equipment that cannot tolerate power interruptions without production losses.
Physical Profile
The tower form factor provides stability for this substantial 1134-pound system, with dimensions optimized for floor placement in equipment rooms or dedicated UPS spaces. The 79-inch height, 24-inch width, and 43-inch depth create a substantial footprint that accommodates the internal battery banks and power electronics while allowing adequate ventilation for heat dissipation. The design includes provisions for optional casters or lifting points to facilitate positioning during installation.
- Width
- 23.62" (599.95 mm)
- Depth
- 43.30" (1099.82 mm)
- Height
- 79.13" (2009.90 mm)
- Weight
- 1133.99 lb (514370 g)
What's in the Box
The complete package includes all components necessary for immediate deployment of the UPS system.
Highlights
- 140 kVA three-phase double-conversion online UPS
- Dual-voltage input/output (120V AC and 230V AC)
- Pure sine wave output for sensitive equipment
- Tower form factor for standalone deployment
- SNMP, SSH, and Telnet network management
- Hardwired plug and receptacle connections
- Includes seven 20kVA power modules
- RoHS compliant and environmentally friendly
- 1-year limited warranty
- Made in China with global compliance standards
Specifications
| Specifications | |
|---|---|
| Manufacturer | Eaton Corporation |
| Manufacturer Part Number | SV140KL7P |
| Brand Name | Tripp Lite series |
| Product Line | SmartOnline |
| Product Series | SV |
| Product Model | SV140KL7P |
| Product Name | SmartOnline SV140KL7P 140kVA Tower UPS |
| Product Type | Double Conversion Online UPS |
| Technical Information | |
| Plug/Connector Type | Hardwired |
| Receptacle Type | Hardwired |
| Phase | Three Phase |
| Power Description | |
| Load Capacity (VA) | 140 kVA |
| Input Voltage | 120 V AC,230 V AC |
| Output Voltage | 120 V AC,230 V AC |
| Waveform Type | Pure Sine Wave |
| Management | |
| Network Management | SNMP Manageable,SSH,Telnet |
| Physical Characteristics | |
| Form Factor | Tower |
| Height | 79.13" (2009.90 mm) |
| Width | 23.62" (599.95 mm) |
| Depth | 43.30" (1099.82 mm) |
| Weight (Approximate) | 1133.99 lb (514370 g) |
| Miscellaneous | |
| Package Contents | SmartOnline SV140KL7P 140kVA Tower UPS Pre-installed network interface 7 X SV20PM 20kVA power modules Owner's manual DB9 Cable |
| Country of Origin | China |
| Environmentally Friendly | Yes |
| Environmental Compliance | Restriction of Hazardous Substances (RoHS) |
| Warranty | |
| Limited Warranty | 1 Year |
User Manual
FAQ
What type of UPS topology does the SV140KL7P use?
The Tripp Lite SV140KL7P employs double-conversion online topology, which continuously converts incoming AC power to DC and then back to clean AC output. This provides complete isolation from utility power anomalies, including sags, surges, harmonics, and frequency variations, with zero transfer time to battery during outages for maximum protection of critical loads.
What power capacity does this UPS provide?
This UPS delivers 140 kVA (kilovolt-amperes) of power capacity, suitable for protecting substantial three-phase loads in data centers, industrial facilities, or large network operations. The capacity represents the maximum apparent power the system can deliver to connected equipment while maintaining proper voltage regulation and runtime performance.
What input and output voltages does it support?
The SV140KL7P supports dual-voltage operation with both 120 V AC and 230 V AC input and output configurations. This flexibility allows deployment in facilities with different electrical standards without requiring external transformers, simplifying installation in global operations or locations transitioning between voltage systems.
How is this UPS managed and monitored?
Management occurs through a pre-installed network interface supporting SNMP (Simple Network Management Protocol), SSH (Secure Shell), and Telnet protocols. This enables remote monitoring of power quality, configuration of alert thresholds, scheduling of self-tests, and initiation of graceful shutdown sequences from any network-connected workstation or management console.
What is included in the package contents?
The complete package includes the SmartOnline SV140KL7P 140kVA Tower UPS unit, a pre-installed network interface card, seven SV20PM 20kVA power modules, an owner's manual, and a DB9 cable for local management connections. All components are factory-installed and tested for immediate deployment upon receipt.
What are the physical dimensions and weight?
The tower UPS measures 79.13 inches tall, 23.62 inches wide, and 43.30 inches deep (approximately 2009.90 × 599.95 × 1099.82 mm), with an approximate weight of 1133.99 pounds (514,370 grams). These substantial dimensions accommodate the internal battery banks, power electronics, and cooling systems required for 140 kVA three-phase operation.
What power capacity is listed for this UPS?
The listed power specification is 140 kVA, which helps position the unit for the right load level and installation role.
What voltage details are listed?
The listed power specification is 120 V AC,230 V AC, which helps position the unit for the right load level and installation role.