Flexible Electrical Cord Cable - 18AWG 3C SJT 300V 105C - Black (Per Meter)
Have questions?
Proud Canadian team since 2007
Consulting & Technicians services
From VoiP phone to Cluster servers
Shipped Trough UPS & Purolator
This bulk power cable consists of three 10 gauge conductors with a 300V SJT jacket. It is generally used to manufacture single phase IEC and NEMA cord sets. The cable is sold in bulk per meter.
Annealed Bare Copper Conductors
|
Physical Characteristics | |
---|---|
Color | Black |
Color Code | Black, White, Green |
Wire Gauge | 10AWG |
Construction | 105/?0.254±0.005 |
Number of Conductors | 3 |
Conductor Material | Annealed Bare Copper |
Insulation Material | PVC - Polyvinyl Chloride |
Insulation Diameter | 5.4 ± 0.10 |
Jacket | SJT |
Jacket Material | PVC - Polyvinyl Chloride |
Jacket Fire Rating | FT2 |
Jacket Overall Diameter | 14.6 ± 0.2 |
Minimum Average Thickness | 1.52mm |
Core Assembly Twist | 3-Core |
Core Assembly Filler | Cotton 20000D |
Temperature Rating | 105? |
Performance | |
Rating Voltage | 300V |
Insulation Resistance | ? 0.76M?/Km 15.0? Min |
Dielectric Strength | AC 2.0KV/1 min No Crack |
Spark Test | 6KV/0.15 Sec |
Insulation Unaged Tensile Strength / Elongation | 1500 lbs/in2 min / 100% Min |
Insulation Aged Tensile Strength / Elongation |
Min 85%(136±1?x168hrs) / Min 65%(136±1?x168hrs) |
Jacket Unaged Tensile Strength / Elongation | 1500 lbs/in2 min / 100% Min |
Jacket Aged Tensile Strength / Elongation | Min 85%(136±1?x168hrs) / Min 45%(136±1?x168hrs) |
Deformation Test | 121±1?m X 1hr ? 50% |
Cold Bend Test | -20? x 4hr No Crack |
Heat Shock Test | 121±1? x 1hr No Crack |
Approvals | |
c(UL)us | Yes |
Environmental | |
RoHS | Yes |
Packaging Information | |
Package Quantity | 1 |
Product Weight | 0.03 lbs |