Server Technology PRO2 48-Outlets PDU - Switched - IEC 60309 3P+N+G 9Hr 60A - 30 x IEC 60320 C13, 18 x CX - 230 V AC - Branch Circuit, (C2WG48TE-YQME2M99)
-
Business Pricing
Volume deals available
-
IT Experts
Consulting & support
-
Config Service
From PC to server
-
Canada Stocked
Toronto - Alberta - BC
- Whether you are a lefty or a righty, the symmetrically shaped mouse suits both
- USB Type A connectivity for a easy connection
- Optical LED for smoother movement and hassle-free performance
- HTTP/HTTPS
- TLSv1.2
- SSHv2
- Telnet
- SNMPv2c
- v3 (GET, SET, Traps)
- IPv4 and IPv6
- LDAPv3/LDAPS
- TACACS+
- RADIUS
- FTP/SFTP
- PRO2 48-Outlets PDU
- Standard Button Mounts
PDU Type: Switched
Phase: Three Phase
Plug/Connector Type: IEC 60309 3P+N+G 9Hr 60A
Receptacle Type: IEC 60320 C13,CX
Receptacle Detail: 30 x IEC 60320 C13,18 x CX
Protection Type: Branch Circuit,Circuit Protection,Fuse
Features: LED Display
Input Voltage: 230 V AC
Output Voltage: 208 V AC
Power Rating (Watt): 17.30 kW
Input Current: 60 A
Input Frequency: 60 Hz
Management:
Remote Outlet Switching: Yes
Network (RJ-45): Yes
Mount Type: Rack-mountable,Cabinet-mountable,Button Mount
Cord Length: 10 ft (3.05 m)
Height: 80" (2032 mm)
Width: 2.20" (55.88 mm)
Depth: 2.50" (63.50 mm)
Minimum Operating Temperature: 32°F (0°C)
Maximum Operating Temperature: 140°F (60°C)
Minimum Storage Temperature: -40°F (-40°C)
Maximum Storage Temperature: 185°F (85°C)
Minimum Operating Humidity: 8%
Maximum Operating Humidity: 90%
Package Contents:
Application/Usage: IT Equipment,Server Rack/Cabinet
Limited Warranty: 2 Year
- HDOT Cx: Cx is the future ready UL tested hybrid of the C13 and C19 outlets accommodating both C20 and C14 plugs.
- Network Monitoring: Gain access to valuable data through connections including HTTP(S), SSH, Telnet, SNMP, (S)FTP, SMTP, Syslog, LDAP(S), RS-232 serial, and more.
- Hot-Swap Network Card: Network access is ensured when power is lost to the primary unit with backup power provided by the primary link unit.
- Star Multi-Linking: Provides the ability to link up to four power circuits using one IP address. Primary link provides backup power to network card.
- Temperature/Humidity Monitoring: Primary and Link units each support two external 10' (3m) T/H probes. Receive SNMP-based alerts and email notifications.
- Auto-Flip Current Display: Easy-to-read LEDs display current per phase to help prevent overloads and simplify three-phase load balancing in high-density cabinets.
- Per- Inlet Power Sensing: Meets ANSI C12.1 for billing-grade accuracy of Current per phase. PIPS includes voltage, active power, apparent power, power factor, and energy.
- Per-Outlet Power Sensing: POPS® (Per Outlet Power Sensing) Monitors Current Load (A), Voltage (V), Power (W), Apparent Power (VA), Crest Factor, Power Factor, and Energy per outlet.
- Branch Current Monitoring: Monitors current at each breaker branch and provides SNMP-based alerts and emails on high usage that risks a tripped circuit.
- Branch Circuit Protection: This PDU meets the UL and IEC 60950-1 requirement for branch circuit protection through use of UL489 rated magnetic-hydraulic circuit breakers or UL248 fuses.
- Outlet Control: On Switched rack PDUs, cycle power to individual outlets or groups of outlets to reboot servers. Or, power off unused receptacles.
- Alternating-Phase Outlets: Evenly distributes multiple phases of power to each outlet for simplified load balancing, reduced cord lengths, and better airflow.
- High Temperature Rating: This product has been tested and approved for safe and reliable operation in 60 °C data center environments.
- Flexible Mounting: Includes standard button mounts along with provisions for custom mounting brackets.
- Color Identification: Choose from six colors to designate circuits for rack PDUs in the data center. Color options include Blue, Red, Green, White, Yellow, and Black.
[custom-specifications]
| Specifications | |
| Manufacturer | Legrand Group |
| Manufacturer Part Number | C2WG48TE-YQME2M99 |
| Manufacturer Website Address | http://www.servertech.com |
| Brand Name | Server Technology |
| Product Series | PRO2 |
| Product Name | PRO2 48-Outlets PDU |
| Product Type | PDU |
| Technical Information | |
| PDU Type | Switched |
| Phase | Three Phase |
| Plug/Connector Type | IEC 60309 3P+N+G 9Hr 60A |
| Receptacle Type | IEC 60320 C13,CX |
| Receptacle Detail | 30 x IEC 60320 C13,18 x CX |
| Protection Type | Branch Circuit,Circuit Protection,Fuse |
| Features | LED Display |
| Power Description | |
| Input Voltage | 230 V AC |
| Output Voltage | 208 V AC |
| Power Rating (Watt) | 17.30 kW |
| Input Current | 60 A |
| Input Frequency | 60 Hz |
| Management | |
| Management |
|
| Remote Outlet Switching | Yes |
| Interfaces/Ports | |
| Network (RJ-45) | Yes |
| Physical Characteristics | |
| Mount Type | Rack-mountable,Cabinet-mountable,Button Mount |
| Cord Length | 10 ft (3.05 m) |
| Height | 80" (2032 mm) |
| Width | 2.20" (55.88 mm) |
| Depth | 2.50" (63.50 mm) |
| Environmental Conditions | |
| Minimum Operating Temperature | 32°F (0°C) |
| Maximum Operating Temperature | 140°F (60°C) |
| Minimum Storage Temperature | -40°F (-40°C) |
| Maximum Storage Temperature | 185°F (85°C) |
| Minimum Operating Humidity | 8% |
| Maximum Operating Humidity | 90% |
| Miscellaneous | |
| Package Contents |
|
| Application/Usage | IT Equipment,Server Rack/Cabinet |
| Warranty | |
| Limited Warranty | 2 Year |
[/custom-specifications]
[custom-options]
| Product | Server Technology Water Sensor Probe - For Water Sensor |
| SKU | EMWS-1-1 |
| Sale Price | $109.31 |
| Product | Server Technology Environmental Monitoring System |
| SKU | EMCU-1-1C |
| Sale Price | $405.14 |
[/custom-options]
Warranty Information
2 YearCustomers also viewed