Free Shipping*
Shipping Restrictions
Additional fees may apply for shipments to locations beyond normal service areas and heavy weight or oversize items.
Free Shipping*
Shipping Restrictions
Additional fees may apply for shipments to locations beyond normal service areas and heavy weight or oversize items.
Tripp Lite by Eaton SmartPro SMART2200RXLTAA 1950VA Rack/Tower UPS - 2U Rack/Tower - AVR - 4.50 Hour Recharge - 4 Minute Stand-by - V (SMART2200RXLTAA)
Have questions?
1-844-836-8268
Ask an Experts-
Canadian distributor
Proud Canadian business since 2007
-
IT experts available
Consulting & Technicial services
-
Pre-configuration services
From VoiP phone to Clustered servers
-
Delivering across Canada
Shipping UPS Fedex & Purolator
- Battery Mode
- Battery Low Warning
- Fault/Alarm
- SmartPro SMART2200RXLTAA 1950VA Rack/Tower UPS
- USB Cable
- DB9 Cable
- Rack-mounting Hardware
- Tower Support Stands
- Safety Instructions
- Quick Start Guide
Marketing Information:
Features | 1.95kVA/1.95kW/120V Battery Backup for Distributed IT, Telecom or Enterprise Deployments
This line-interactive UPS system provides reliable battery backup and AC power protection against blackouts, brownouts, surges and line noise that can damage your valuable IT equipment. The SMART2200RXLTAA is ideal for large and small network devices, high-end workstations, storage and security equipment in labs, server rooms and data centers.
Reliable, Expandable Battery Backup Keeps You Operational Through Power Outages
The field-replaceable, hot-swappable VRLA battery modules allow you to work through short power failures and give you enough time to safely save files and shut down your system in case of a prolonged blackout. Switchover from line to battery power happens within milliseconds to maintain continuous operation of connected equipment without interruption or rebooting. Extra runtime is available by connecting up to four optional extended battery modules (BP72VRXLTAA, sold separately). The SMART2200RXLTAA restarts automatically once power is restored, regardless of battery charge level, saving you a costly site visit.
Automatic Voltage Regulation (AVR) Corrects Low- and High-Voltage Conditions
Built-in AVR corrects abnormal voltage conditions without using the battery. The SMART2200RXLTAA maintains regulated 120V nominal output during brownouts and overvoltages from 80V to 151V while keeping the battery fully charged and ready to take over in case of power failure.
Pure Sine Wave Output and Unity Power Factor
Pure sine wave output power ensures maximum stability while unity power factor ensures the most watts possible at each power rating, providing maximum compatibility with sensitive equipment.
Optional LXE Network Management Card Allows Remote Control and Access 24/7
The WEBCARDLXE (sold separately) enables access to advanced features like switchable load banks, automatic email messaging on power events, and full remote control of the UPS. The IP-based Auto Probe feature ensures network uptime by communicating with other network devices and automatically rebooting IT equipment when a loss of connectivity is detected. Note : The SMART2200RXLTAA is not compatible with WEBCARDLX.
Managed NEMA Outlets Protect Your Connected Components
One L5-20R and six 5-20R outlets provide connected equipment with pure sine wave AC output and allow you to monitor power consumption down to the outlet group level. Power provided by these outlets is filtered to protect connected equipment against damaging surges and line noise. Four 5-20R outlets are grouped into two programmable load banks that let you shed non-critical loads to extend runtime for critical loads. Front and rear cooling fans help protect equipment from overheating.
Automatic Voltage Regulation (AVR) Corrects Low- and High-Voltage Conditions
AVR protects your equipment from incremental hardware damage, data loss and performance problems caused by brownouts. The SMART2200RXLTAA maintains regulated 120V nominal output during brownouts and overvoltages from 80V to 151V while keeping the battery fully charged and ready to take over in case of power failure.
Premium Protection from EMI/RFI Line Noise Helps Your Equipment Perform Better
This UPS system filters out disruptive electromagnetic and radio frequency interference that can inflict hardware damage or data loss. This EMI/RFI filtering also helps your connected components perform better and last longer.
AVR: Yes
Plug/Connector Type: NEMA 5-20P
Receptacle Type: NEMA 5-20R,NEMA L5-20R
Receptacle Detail: 6 x NEMA 5-20R,1 x NEMA L5-20R
Number of Load Management Outlets: 2
Cord Length: 10 ft (3.05 m)
Transfer Time: 4 ms
EMI/RFI Noise Filter: Yes
Phase: Single Phase
Efficiency Detail: 96% (AC Mode)
Application/Usage: Server,Switch,IT Equipment,Telecommunication,Enterprise,Workstation,Storage,Security,Lab Equipment,Server Room,Data Center,Network,Desktop
Surge Suppression: Yes
Features: Cold Start Function
Load Capacity (VA): 1.95 kVA
Load Capacity (Watt): 1.95 kW
Input Voltage: 120 V AC
Input Voltage Range: 70 V AC - 153 V AC
Input Current: 16 A
Output Voltage: 120 V AC,100 V AC,110 V AC,125 V AC
Output Frequency: 50 Hz,60 Hz
Waveform Type: Pure Sine Wave
Surge Energy Rating: 380 J
Circuit Breaker: Yes
Output Power Factor: 1
Display: LCD
Network Management: Dry Contact,DB-9 RS-232,Contact Closure,SNMP/Web
Alarm: Power Failure,Low Battery,Overload,UPS Fault,Remote Shutdown
Status Indicators:
LED Indicators:
Serial Port: Yes
USB: Yes
EPO Port: Yes
USB (HID Compliant) Port: Yes
DC System Voltage: 72 V DC
Battery Characteristics: Valve-regulated
Battery Chemistry: Lead Acid
Backup/Run Time (Full Load): 4 Minute
Backup/Run Time (Half Load): 12 Minute
Hot Swappable: Yes
Typical Battery Recharge Time: 4.50 Hour
Replaceable Battery: Yes
Maximum Storage Elevation: 32808 ft (9999878.40 mm)
Storage Temperature: 5°F (-15°C) - 122°F (50°C)
Minimum Operating Temperature: 32°F (0°C)
Maximum Operating Temperature: 104°F (40°C)
Sound Emission (A-Weighted): 45 dB(A)
Thermal Dissipation: 591 BTU/h
Height: 3.40" (86.36 mm)
Width: 17" (431.80 mm)
Depth: 23" (584.20 mm)
Rack Height: 2U
Form Factor: Rack/Tower
Weight (Approximate): 65.30 lb (29619.58 g)
Package Contents:
Energy Star: Yes
TAA Compliant: Yes
Energy Efficiency Certification: ENERGY STAR 2.0
Environmental Compliance: Restriction of Hazardous Substances (RoHS)
Limited Warranty: 3 Year
Additional Warranty Information:
2-year warranty, 3 year with registration.
- Experience higher efficiency with lower energy cost
- 1.95 kW load capacity - backup power for your valuable electronics
- Up to 4 minute runtime on full load to preserve critical data from power shortage interruptions
- 1.95 kVA load capacity provides sufficient backup during power failures
[custom-specifications]
Specifications | |
Manufacturer | Eaton Corporation |
Manufacturer Part Number | SMART2200RXLTAA |
Manufacturer Website Address | http://www.eaton.com/EatonCom/Markets/NorthAmerica |
Brand Name | Tripp Lite by Eaton |
Product Line | SmartPro |
Product Model | SMART2200RXLTAA |
Product Name | SmartPro SMART2200RXLTAA 1950VA Rack/Tower UPS |
Product Type | Line-interactive UPS |
Technical Information | |
AVR | Yes |
Plug/Connector Type | NEMA 5-20P |
Receptacle Type | NEMA 5-20R,NEMA L5-20R |
Receptacle Detail | 6 x NEMA 5-20R,1 x NEMA L5-20R |
Number of Load Management Outlets | 2 |
Cord Length | 10 ft (3.05 m) |
Transfer Time | 4 ms |
EMI/RFI Noise Filter | Yes |
Phase | Single Phase |
Efficiency Detail | 96% (AC Mode) |
Application/Usage | Server,Switch,IT Equipment,Telecommunication,Enterprise,Workstation,Storage,Security,Lab Equipment,Server Room,Data Center,Network,Desktop |
Surge Suppression | Yes |
Features | Cold Start Function |
Power Description | |
Load Capacity (VA) | 1.95 kVA |
Load Capacity (Watt) | 1.95 kW |
Input Voltage | 120 V AC |
Input Voltage Range | 70 V AC - 153 V AC |
Input Current | 16 A |
Output Voltage | 120 V AC,100 V AC,110 V AC,125 V AC |
Output Frequency | 50 Hz,60 Hz |
Waveform Type | Pure Sine Wave |
Surge Energy Rating | 380 J |
Circuit Breaker | Yes |
Output Power Factor | 1 |
Display & Graphics | |
Display | LCD |
Management | |
Network Management | Dry Contact,DB-9 RS-232,Contact Closure,SNMP/Web |
Alarm | Power Failure,Low Battery,Overload,UPS Fault,Remote Shutdown |
Controls/Indicators | |
Status Indicators | LED Indicators:
|
Interfaces/Ports | |
Serial Port | Yes |
USB | Yes |
EPO Port | Yes |
USB (HID Compliant) Port | Yes |
Battery Information | |
DC System Voltage | 72 V DC |
Battery Characteristics | Valve-regulated |
Battery Chemistry | Lead Acid |
Backup/Run Time (Full Load) | 4 Minute |
Backup/Run Time (Half Load) | 12 Minute |
Hot Swappable | Yes |
Typical Battery Recharge Time | 4.50 Hour |
Replaceable Battery | Yes |
Environmental Conditions | |
Maximum Storage Elevation | 32808 ft (9999878.40 mm) |
Storage Temperature | 5°F (-15°C) - 122°F (50°C) |
Minimum Operating Temperature | 32°F (0°C) |
Maximum Operating Temperature | 104°F (40°C) |
Sound Emission (A-Weighted) | 45 dB(A) |
Thermal Dissipation | 591 BTU/h |
Physical Characteristics | |
Height | 3.40" (86.36 mm) |
Width | 17" (431.80 mm) |
Depth | 23" (584.20 mm) |
Rack Height | 2U |
Form Factor | Rack/Tower |
Weight (Approximate) | 65.30 lb (29619.58 g) |
Miscellaneous | |
Package Contents |
|
Energy Star | Yes |
TAA Compliant | Yes |
Energy Efficiency Certification | ENERGY STAR 2.0 |
Environmental Compliance | Restriction of Hazardous Substances (RoHS) |
Warranty | |
Limited Warranty | 3 Year |
Additional Warranty Information | 2-year warranty, 3 year with registration. |
[/custom-specifications]
[custom-options]

Product | Tripp Lite PDUMH20 PDU Metered 120V 20A 12 Outlet - 12 x NEMA 5-15/20R - 1U 19" Rack-mountable, Zero U 19" Vertical Rackmount |
SKU | PDUMH20 |
Sale Price | $221.25 |

Product | Tripp Lite PDUMNH20 PDU Monitored 120V 20A 8 Outlet - 16 x NEMA 5-15/20R - 1U Horizontal Rackmount |
SKU | PDUMNH20 |
Sale Price | $625.67 |

Product | Tripp Lite PDUMV20 PDU Metered 120V 20A 28 Outlet - 28 x NEMA 5-15/20R - 2.4kW - Zero U Vertical Rackmount |
SKU | PDUMV20 |
Sale Price | $238.35 |